background image

1.  By-Pass Valve Handle (2) must be turned to  

     left as far as possible and remain so until tap  

     is made.

2.  Raise Boring Bar, close Gate Valve; then turn  

     By-Pass Valve Handle (2) to right as far as  

     possible.

3.  Proceed according to machine instructions,  

     and when cap is again in place, turn By-Pass  

     Valve Handle (2) to left as far as possible to  

     equalize pressure in bottom and top of Cylinder.  

     Open Gate Valve and insert Corp Stop.

4.  Then turn By-Pass Valve Handle (2) to right as far  

     as possible and remove machine.

5.  To clean valve – to remove dirt or chips from  

     Valve, remove Screw (1) so Handle (2) can be  

     taken from Stem (4), unscrew Nut (3) then  

     unscrew Stem (4) until out of Valve. Take a piece  

     of wire and clean Valve Port (5).

LEAVE THIS TAG HERE UNTIL YOU ARE 

PERFECTLY FAMILIAR WITH THE OPERATION  

OF THIS BY-PASS VALVE.

Valve Instructions (continued)

By deviating from the above listed instructions, you will void any 

product warranty and release Mueller Co. and its affiliated entities 

from any and all liability associated with the installation or use of 

this product. For details on the product’s warranty, terms, and 

conditions, please visit www.muellercompany.com.

Phone: (800) 423-1323                     

© 2016 Mueller Co., LLC. All rights reserved.

Form 5272     06/16