![Much More Water BlueBox 1200 RORS Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/much-more-water/bluebox-1200-rors/bluebox-1200-rors_operating-manual_1853353005.webp)
5
C
LE
AN WAT
ER
R
A
W
W
ATER
IN
LE
T
FL
U
SH
WATER
O
U
TL
ET
365
5
Let the pump run for 1-2
minutes until no more bubbles
are detected from the red hose.
6
Turn the blue pressure valve
clockwise
until pressure is
approximately 8 bars.
7
Open the grey electrical cabinet
and check that the UV display
unit is active and that the
display shows the number of
days left.
The UV light must be changed
after 365 days of operation.
Please see maintenance
section.
8
Non-potable (not suitable for
drinking) water will come out
of the red hose (Flush water
outlet).
Drinking water can be tapped
from the blue hose (Clean
water).
The flow meter shows the
volume of clean water.
WARNING!
Never drink the water from the
blue fresh-water tube before the
BlueBox has been working for at
least 3-5 minutes!
Flush water
outlet
(Red hose)
Raw
water inlet
(Black hose)
Clean
water outlet
(Blue hose)
ill. 11
ill. 9
ill. 10
Wait 3-5
minutes
Pressure valve
Electrical cabinet
UV display
Air filter