background image

Muarah

 

MU-4 TUBE INTEGRATED AMPLIFIER 

USER MANUAL 

 

v1.2 

7

 

3)

 

When you plan not to use remote controller for a longer period of time (over 3 months) remove 
batteries from controller. 

Important safety instructions! 

1)

 

WARNING!!!

 During amplifier operation there is high voltage up to DC 500V existing inside MU-

4  that  is  dangerous  to  human’s  life.  So 

on  no  account  should  you  insert  anything  into 

ventilation  slots  or  into  tube’s  sockets. 

If  it  happens  accidentally  do  not  touch  amplifier  and 

disconnect AC mains plug from AC outlet as quick as possible. Then contact authorized service to 
remove foreign body and check amplifier circuits. 

2)

 

Vacuum tubes get hot over 100

o

C  (210

o

F) during normal operation. Touching tubes can cause 

scorch so locate MU-4 amplifier in  place inaccessible for children and pets.  

3)

 

Amplifier can be connected to AC mains power only when all vacuum tubes are installed 

4)

 

On any account should you open MU-4 amplifier bottom cover! 

Parameters 

 

Power frequency re0dB/-1,5dB 

20Hz-20kHz @ 50W 

 

Frequency re0dB/-3dB 

10Hz-70kHz 

 

Nominal Power at THD=2% 

2x50W 

 

Signal to noise 

>96dBA 

 

Speaker outputs 

 

Headphones output 

4 or 8 Ω (separate outputs) 
6,3mm jack plug. Headphones 30-300 Ω 

 

Inputs 

3 x unbalanced RCA 

 

Tubes 

2x6N1P, 2x12BH7, 4xKT88 (or 6550) 

 

Dimensions (width/length/height) 

43,5cm/43,5cm/23,5cm 

 

Weight 

20kg 

 

Power consumption 

< 400VA  

 

 

 

 

Содержание MU4

Страница 1: ...s soul as a contrast to pervasive trumpery and mediocrity Using those special things shall be inspiring and nice Our inspiration are audio and automotive worlds seemingly outlying but in fact having a...

Страница 2: ...several modern technical solutions delivers true tube sound with well controlled low frequencies region what is difficult to achieve in tube designs Entire audio band is perfectly handled by MU 4 High...

Страница 3: ...hones output Remote controller with SWAROVSKI push buttons Microprocessor controlled circuit Connection 1 Carefully take MU 4 out of the shipping carton and plastic bag Use attached rubber coated glov...

Страница 4: ...7 Connect AC main power WARNING Main AC Power going to MU 4 should not be applied until all the system components are connected together AC mains power cord has to be connected to MU 4 first and then...

Страница 5: ...eft or right channel by turning appropriate bias potentiometer c Proper bias level 50mA is when red bar on the VOLUME indicator e reach middle position see attached picture When lower bias is too low...

Страница 6: ...ube glass should be wiped out using soft cotton cloth soaked with spirit 6 For a best performance electrically matched vacuum tube pairs 6N1P 12BH7 and quartets KT 88 shall be used 7 After tubes repla...

Страница 7: ...rvice to remove foreign body and check amplifier circuits 2 Vacuum tubes get hot over 100o C 210o F during normal operation Touching tubes can cause scorch so locate MU 4 amplifier in place inaccessib...

Отзывы: