![MTU 12V2000Gx5 Скачать руководство пользователя страница 84](http://html1.mh-extra.com/html/mtu/12v2000gx5/12v2000gx5_operating-instructions-manual_1852664084.webp)
7.2 Troubleshooting
Engine does not turn when starter is actuated
Cause
Corrective action
Battery flat or faulty.
u
Charge or replace battery (see manufacturer's documentation).
Cable connections on battery are
faulty.
u
Check if cable connections are properly secured (see
manufacturer's documentation).
Engine wiring or starter faulty.
u
Check if cable connections are properly secured, contact Service.
Engine wiring is faulty.
u
Check (→ Page 154).
Loose plug connections at
engine/generator control system.
u
Perform visual inspection (see manufacturer's documentation).
Loose plug connection are loose
at engine governor.
u
Check plug connections (→ Page 156).
Engine blocked (cannot be rotated
by hand).
u
Contact Service.
Engine turns but does not fire
Cause
Corrective action
Poor rotation by starter: Battery
flat or faulty.
u
Charge or replace battery (see manufacturer's documentation).
Engine wiring is faulty.
u
Check (→ Page 154).
Air in fuel system
u
Vent fuel system (→ Page 117).
Engine governor is faulty.
u
Contact Service.
Engine fires unevenly
Cause
Corrective action
Injector is faulty.
u
Replace (→ Page 105).
Injection pump is faulty.
u
Replace (→ Page 102).
Engine wiring is faulty.
u
Check (→ Page 154).
Air in fuel system
u
Vent fuel system (→ Page 117).
Engine governor is faulty.
u
Contact Service.
Engine does not reach rated speed
Cause
Corrective action
Fuel prefilter clogged.
u
Replace filter element (→ Page 126).
Easy-change fuel filter clogged.
u
Replace (→ Page 119).
Air filter clogged.
u
Check signal ring position of contamination indicator (→ Page 131).
Injector is faulty.
u
Replace (→ Page 105).
Injection pump is faulty.
u
Replace (→ Page 102).
Engine wiring is faulty.
u
Check (→ Page 154).
Overload.
u
Contact Service.
84 | Troubleshooting | MS15019/04E 2016-02
TIM-ID: 0000066976 - 001