![MTT MS3713 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/mtt/ms3713/ms3713_user-manual_1852575002.webp)
User's Manual
MS3713
Slim Plug-In Square-Root Extractor with Isolated Single/Dual Output
Rev. 1.40
2
On Wiring:
Connections to the instrument should be made to the terminal
block. For assignment of the terminals, refer to section 6. The
recommended screwing torque is 0.8 to 1.0 Nm.
For lead wires, use a highly flexible stranded conductor. The
recommended nominal cross-section of the lead wire conductor
is 0.5 to 2.0 mm
2
.
The connection of the lead wire to the terminal block should be
made with the insulated crimp terminal attached to the end of the
wire. Without the insulation, short circuit or electric shock may
occur. The recommended thickness of the crimp terminal is 0.7
to 1.0 mm.
Note that only up to two (2) crimp terminals can be connected to
one (1) terminal screw. In this case, the thickness of the crimp
terminal should be not greater than 0.8 mm.
φ3.7
6.8
m
ax
.
3.4 max.
4.6 min.
To Avoid Erroneous Measurements:
In order to reduce the influence of noise, the input/output wire
and power supply wire should not be used in a same bundle or
same conduit. They should be installed separately with a
minimum distance of 200 mm.
Avoid wiring the signal lines in the vicinity of equipment
generating magnetic fields or electromagnetic waves, such as
electric motors and large-scale transformers. If inevitable,
anti-noise measures such as employment of shielded wires are
indispensable.
At least 30 minutes of warm-up is required prior to operation.
Any sensor or equipment to be connected to the instrument
should be selected in consideration of the input/output
impedance of the same. (For detailed specifications, refer to
section 4 or the relevant product specification sheet that can be
downloaded from our website at https://www.mtt.co.jp.)
4. About the Product
The MS3713 extracts the square roots of DC input signals and
converts them into isolated DC output.
Features:
Pin and socket contacts are gold-plated (0.2
μ
m) to ensure high
reliability and long-term stability.
High dielectric strength of 2,000 VAC between input, [output 1,
output 2], power, and ground.
The power unit can deliver AC power ranging from 85 to 264V
steplessly without switching to meet varied power requirements.
Plug-in type for better maintainability
Drop-proof terminal screws for ease and safety of installation
Fuse installed in the power line as standard.
Specifications
Input Resistance
Voltage input:
1M
Ω
min. with or without power.
Current input:
4 to 20mA DC: 250
Ω
(standard)
2 to 10mA DC: 250
Ω
1 to 5mA DC: 100
Ω
0 to 20mA DC: 250
Ω
10 to 50mA DC: 10
Ω
Allowable Input
Voltage
Voltage input: 30V DC max., continuous.
(Standard for a span up to 10V)
Current input: 40mA DC max., continuous.
(Standard for 4 to 20mA)
Allowable Output
Load
Voltage output:
1V span and up: 2mA max.
10mV: 10k
Ω
min.
100mV: 100k
Ω
min.
Current output:
Single current output:
750
Ω
max. (for 4-20mA output)
Dual current output:
Output 1: 550
Ω
max. (for 4-20mA output)
Output 2: 350
Ω
max. (for 4-20mA output)
Zero Adjustment
Approx. ±5% of span.
(Adjustable by the front-accessible trimmer.)
Span Adjustment
Approx. ±5% of span.
(Adjustable by the front-accessible trimmer.)
Square-Root
Extraction
X = 10 ×
√
Y
Where:
X = Output signal (0 to 100%)
Y = Input signal (0 to 100%)
Note that a cutoff function works when the
output reaches 8%±1%.
Accuracy Rating
Better than ±0.2% of span (with input of 1 to
100%, at 25°C±5°C)
Temperature
Effect
Better than ±0.2% of span per 10°C change in
ambient.
Response Time 120ms max. (0-90%) with a step input at 100%.
Insulation
Resistance
100M
Ω
min. (@ 500V DC) between input,
output 1, output 2, power, and ground.
Dielectric
Strength
Input / [Output 1, Output 2] / [Power, Ground]:
2000V AC for 1 minute (Cutoff current: 0.5mA)
Power / Ground: 2000V AC for 1 minute (Cutoff
current: 5mA)
Output 1 / Output 2: 500V AC for 1 minute
(Cutoff current: 0.5mA)
Surge Withstand
Capability
Tested as per ANSI/IEEE C37.90.1-1989.
Storage
Temperature
-10 to 60°C
Installation Position
Typical Installation Example