15
Jumper Selections
RESET
I/O WIRING
SIMULATED
ENCODER
FEEDBACK WIRING
DIP 1
ON
1 2 3 4
JP9
JP11
JP3
JP19
JP3
BI-POLAR
ABSOLUTE (STANDARD)
The position of this jumper determines the kind of dc voltage proportional to current that is a
diagnostic signal at the (CUR) output of the I/O connector. With the shorting pin in the bipolar
position, the output CUR signal is plus for positive current and minus for negative current. The
voltage range is plus and minus ten where ten equals the amplifiers continuous current. With
the jumper in absolute, the proportional voltage is always positive for either plus or minus
motor current.
JP19
SPINDLE ORIENT ENABLE
disabled
enabled
(STANDARD)
The position of this jumper determines whether the shaft will turn at 1 rps when PIN 13 is
grounded.
Содержание MAXPLUS 306
Страница 23: ...23 Motor and Motor Relay Wiring...
Страница 26: ...26 Shunt Amplifier Wiring...
Страница 27: ...27 EXS 50 230 Mechanical Footprint 0 5 6 16 0 15 5 0 5 0 0 1 0 8 5 9 5...