MTS Sensors Temposonics Скачать руководство пользователя страница 7

High Pressure Housing

Operation Manual

I

 7 

I

ACCESSORIES 

See document “551 444” for further accessories.

Position magnet

Cable glands ATEX

Ø 32.8

(Ø 1.29)

Ø 23.8

(Ø 0.94)

Ø 13.5

(Ø 0.53)

 

Ø 4.3

(Ø 0.17)

7.9

(0.31)

Ring magnet OD33

Part no. 201 542-2

M20 × 1,5 

Part no. CG-816679

M20 × 1,5

Part no. CG-816609

½" NPT cable gland ATEX/CSA US, 

180 °C; Part no. 403 042

Material: PA ferrite GF20

Weight: ca. 14 g

Operating temperature: −40…+100 °C

Surface pressure: max. 40 N/mm

2

Fastening torque for M4 screws:

max. 1 Nm

Type no. ADE1F-4

Material: stainless steel

Cable Ø: 4…8,5 mm

Type no. ADE1F-6

Material: stainless steel

Cable Ø: 8.5…16 mm

Type no. A3LF/16 ½ NPT

Material: nickel plated brass

Cable Ø: 4…8.4 mm

Spanner tool

Part no. DIN 1018A AMF 80-90 mm

HPH rotation adapters

For M18, M30×1,5

Part no. RTA-M18

For ¾

"

 UNF; 1 1/16

Part no. RTA-¾

"

 UNF-2

For ¾

"

 UNF; 1 ¼

"

Part no. 253 961

Cable connectors

Ø 17.3 (Ø 0.68)

 ~ 60.5

(

2.38)

Female, straight, 6 pin

Part no. 370 423

Female, straight, 6 pin with 

10 m PUR cable

Part no. MTS-A-370423-1000-530052

Housing: zinc nickel plated

Termination: solder

Contact insert: silver plated

Cable clamp: PG9

Cable Ø: 6…8 mm

Содержание Temposonics

Страница 1: ...Temposonics Magnetostrictive Linear Position Sensors High Pressure Housing HPH Operation Manual...

Страница 2: ...in this housing you get a cost efficient solution for use in haz ardous locations which also allows easy sensor replacement Several design combinations are available to fit your application M18 or UN...

Страница 3: ...ad zone 64 mm 2 52 in Zone 1 Zone 0 Stroke length 5000 mm 200 in 66 mm 2 61 in M5 Magnet M18 1 5 6g 16 UNF 3A 64 mm 2 52 in 85 mm 3 45 in 69 mm 2 72 in 86 mm 3 41 in 25 mm 1 in Short top 158 mm Long t...

Страница 4: ...isting and physical damage The normal way is that the sensor and the HPH housing are in one order and then MTS Sensors supply the sen sor mounted in the WPH housing Go to step 7 2 Remove rod or profil...

Страница 5: ...tom flanges come together 3 6 Tighten gable gland according to the manufacturer s specifications 4 Side mounted cable gland s 4 1 Enter the cable through the gland without tightening 4 2 For cable siz...

Страница 6: ...5 Insert a bag of Desiccant in the top 4 6 Assemble the top and bottom turning clockwise and tighten firmly until top and bottom flanges come together see fig 11 Tighten the cable glands according to...

Страница 7: ...tening torque for M4 screws max 1 Nm Type no ADE1F 4 Material stainless steel Cable 4 8 5 mm Type no ADE1F 6 Material stainless steel Cable 8 5 16 mm Type no A3LF 16 NPT Material nickel plated brass C...

Страница 8: ...Branch Of ce Phone 81 3 6416 1063 E mail info jp mtssensors com www mtssensors com MTS Temposonics and Level Plus are registered trademarks of MTS Systems Corporation in the United States MTS SENSORS...