In order to return to normal operation, wait until the stove has cooled down
(i.e. the fan has switched off and the chamber is cooled down) and press the button on the casing of the
bimetallic sensor (reset).
Clean the chamber pan, taking into account that the pan and deflector can still be hot due to the fact that
cast iron keeps temperature for a long time. Then the stove can be switched on according to point 9a.
The
overflow
signal is generated by the mechanical sensor located under the overflow tank.
The contact opening signals that the tank has overflowed and switches off the fuel feeding pump and the fan
keeps operating until the furnace temperature falls below 35°C. When this happens, the stove comes back
to the
Stop
phase.
In order to return to normal operation, wait until the stove has cooled down (i.e. the fan
has switched off and the chamber is cooled down). Drain the overflow tank, clean the furnace pan and the
combustion
chamber, taking into account that the pan and deflector can still be hot due to the fact that cast iron keeps
temperature for a long time. Then the stove can be switched on according to point 9a.
9. Heater operation
CAUTION!!!
DO NOT RE-FILL OIL IN THE FURNACE AND FIRE UP WHEN THE CHAMBER OR
FURNACE PAN ARE STILL HOT!!!
ALWAYS WAIT UNTIL THE FURNACE PLATE HAS FULLY COOLED DOWN. FAILURE TO
OBSERVE THE ABOVE MAY RESULT IN
UNCONTROLLED IGNITION OF OIL VAPOURS AND BURNS!!!
9a. Starting the device.
-
if needed, remove water from the fuel tank and fill it with oil (e.g. used oil),
-
check
whether
the
overflow
protection
mechanism
works
properly
by
pushing the bowl lever down and letting it come back to its original position, which
will be confirmed by the characteristic “click” sound,
-
check whether the device burner is maximally pushed to the housing of the device (if not,
push until resistance),
-
insert the power plug in the power socket (230V / 50Hz),
-
draw the top part of the heater housing aside and remove the combustion chamber cover.
Then, take the cylinder and deflector out (if necessary, thoroughly clean the combustion bowl, the base
which it is placed on and the entire combustion chamber along with the sleeve and deflector),
-
check whether the furnace bowl is cool and clean and pour ca. 250 ml of fuel or diesel
oil,
-
mount the ring and cylinder,
-
fire the oil up using paper crumbled into a ball - set it on fire and throw onto the furnace bowl,
-
replace the combustion chamber cover and close the top housing part of the heater,
-
press the button marked as
NETWORK
into position 1 and turn the power setting knob into 19 kW
or 19 kW, depending on the required heat amount,
-
after about 10-15 minutes, depending on the room temperature, the fuel pump and the fan
are switched on and the red lamp of the 0/1 button is on. The stove has to operate with this power
for at least 15 minutes. After ca. 15 minutes of operation, when the furnace pan is sufficiently heated up
and is able to evaporate a greater amount of oil, the power of the device can be switched to 30 kW or
decreased to 8 kW.