Linking your transmitter and receiver units

You must reset the transmitter unit to factory defaults (to disable encryption) 
before linking the transmitter and receiver units. For more information, see 
the WIO-900LT Transmitter Quick Start Guide.
NOTE: You must complete the linking process in 60 seconds.
To link the transmitter and receiver units:
1.  Press and hold down the RSSI Pushbutton on the receiver.
2.  Power on the receiver while holding down the RSSI Pushbutton
3.  Release the RSSI Pushbutton as soon as the Receiver LEDS flash (within 

5 seconds of powering the receiver).

4.  The receiver will flash all LEDs for a maximum 60 seconds while it tries to 

link to the transmitter.

5.  Power on the transmitter. The transmitter sends a special “Link” message 

to allow the receiver to recognise the transmitter.

6.  When  the  units  link,  the  receiver  lights  all  LEDs  for  2  seconds  before 

returning to normal operation.

NOTE:

  If  the  receiver  LEDs  continue  flashing  within  the  60  seconds,  the 

units are not linked and you should retry the linking process by powering the 
transmitter off and on again. If you exceed the 60 seconds, you must restart 
the linking process from step 1.
You can now bench test your configuration before deploying.

Safety information

Thank you for selecting the WIO-900LR receiver for your telemetry needs. 
We  trust  it  will  give  you  many  years  of  valuable  service.  To  ensure  your  
WIO-900LR receiver enjoys a long life, double-check ALL your connections 
with the user’s manual before powering on the unit.
WARNING: Incorrect termination of supply wires may cause internal damage 
and will void warranty.
Exposure  to  RF  energy  is  an  important  safety  consideration.  The  FCC 
has  adopted  a  safety  standard  for  human  exposure  to  radio  frequency 
electromagnetic energy emitted by FCC regulated equipment as a result of 
its actions in Docket 93-62 and OET Bulletin 65 Edition 97-01.

FCC Notice when used in USA: WIO-900LR Wireless I/O Module

Part

Additional information

15

This device has been tested and found to comply with the limits for a 
Class B digital device, pursuant to Part15 of the FCC rules (Code of 
Federal Regulations 47CFR Part 15). Operation is subject to the condition 
that this device does not cause harmful interference.

90

This device has been type accepted for operation by the FCC in 
accordance with Part90 of the FCC rules (47CFR Part 90). See the 
label on the unit for the specific FCC ID and any other certification 
designations.

Содержание WIO-900LR

Страница 1: ...Quick Start Guide QSG 900LR WIO 900LR wireless I O receiver unit ...

Страница 2: ...he basic steps for using your unit are 1 Connect the antenna power supply and transducer signals using the instructions in this document Power supply and transducer connection is described in the section Unit components and connections Antenna connection is described in the section Antenna installation For more information see the WIO 900L Installation Manual 2 Resetthetransmitterandreceiverunitst...

Страница 3: ...egulations this module must be installed in an Electrical AND Fire enclosure This enclosure may be a single or multiple enclosures Access to the module is to be made by a Service Person only In order to comply with Electrical Safety Standards when connecting SELV AND voltages which are greater than SELV 30VAC or 60VDC together then Relay Output 2 must NOT be used in order to provide sufficient iso...

Страница 4: ...ssed When you press the RSSI push button the unit shows the signal strength by lighting the LEDs from the bottom to the top Signal strength is the strength of the last message received that was addressed to this station LED Signal Strength LED Signal Strength D1 Better than 85 dBm RX Better than 100 dBm D2 Better than 90 dBm CF Better than 105 dBm D3 Better than 95 dBm PG Always on during RSSI tes...

Страница 5: ...0LR receiver flashes all LEDs at medium flash i e 1 6 Hz NOTE If the LEDs do not flash you must repeat steps 1 and 2 until the LEDs flash before continuing 4 Release the RSSI push button within 5 seconds 5 Within a further 60 seconds press and hold the RSSI push button for 5 seconds until the LEDs stop flashing and then release 6 The WIO 900LR receiver lights all LEDs for 2 seconds before returnin...

Страница 6: ...nds you must restart the linking process from step 1 You can now bench test your configuration before deploying 7 Safety information Thank you for selecting the WIO 900LR receiver for your telemetry needs We trust it will give you many years of valuable service To ensure your WIO 900LR receiver enjoys a long life double check ALL your connections with the user s manual before powering on the unit ...

Страница 7: ...t cause harmful interference and This device must accept any interference received including interference that may cause undesired operation NOTE This equipment is suitable for use in Class 1 Division 2 groups A B C and D or non hazardous locations only 8 Unit specifications Input output Number Additional information Digital outputs 3 Voltage free contacts rated at 250 VAC 1A 30VDC 1A 2 for digita...

Страница 8: ...ello Balsamo MI Italy Tel 39 0 2 61802011 Fax 39 0 2 61294560 E mail info mtl inst it Cooper Crouse Hinds Japan KK MT Building 3F 2 7 5 Shiba Daimon Minato ku Tokyo Japan 105 0012 Tel 81 0 3 6430 3128 Fax 81 0 3 6430 3129 E mail sales mtlkk co jp Cooper Crouse Hinds Korea 12F Vision Tower 707 2 Yeoksam dong Gangnam gu Seoul 135 080 South Korea Tel 82 2 3484 6795 Fax 82 2 3484 6778 MTL Instruments ...

Отзывы: