background image

5

INM9468-2

May 2010

APPRoVALs

The operating parameters must not exceed those as detailed on the certificate.

 

2004/108/EC  EMC Directive

 

2006/95/EC 

Low Voltage Directive 

Region

Europe (ATEX)

International IECEx

USA

Canada

Authority

SIRA

SIRA

FM

CSA

Standard

EN 60079-0:2006,

EN 60079-11:2007,

IEC 60079-26:2006,

IEC 61241-0:2004,

IEC 61241-11:2005

IEC 60079-0:2004,

IEC 60079-11:2006,

IEC 60079-26:2006,

IEC 61241-0:2004,

IEC 61241-11:2005

3600

3610

3810

C22.2 No. 61010.1:2004

C22.2 No. 157:1992

CAN/CSA-E60079-0:2007

CAN/CSA-E60079-11:2002

Approved for

E

 II (1) GD

E

 I (M1)

(Ga) [Ex ia] IIC

[Ex iaD]

(Ma) [Ex ia] I

(Ta = –40˚C to +70˚C)*

(Ga) [Ex ia] IIC

[Ex ia D]

(Ma) [Ex ia] I

(Ta = –40°C to +70°C)*

AIS/I/1/ABCD/T4 

Ta=70°C

[I]/[0]/[AEx ia] IIC T4 

Ta=70°C

AIS/I/1/ABCD/T4 Ta=70°C

[I]/[0]/[AEx ia] IIC T4 

Ta=70°C

Cert. no.

Sira 07ATEX2065

IECEx SIR 07.0043

3034995

3034995C

* (see specification for operating temperature range)

Region

Europe (ATEX)

International IECEx

USA

Canada

Authority

SIRA

SIRA

FM

FMC

Standard

EN 60079-0:2006,

IEC 60079-0:2007†,

EN 60079-11:2007,

EN 60079-15:2005,

IEC 60079-26:2006

IEC 60079-0:2004,

IEC 60079-11:2006,

IEC 60079-15:2005-03

 

Approved for

II 3 G

Ex ic (ia) IIC T4 Gc

(Ta = –40˚C to +70˚C)*

Ex nLc nAc (ia) IIC T4

(Ta = –40˚C to +70˚C)*

Ex ic [ia] IIC T4 Gc

(Ta = –40°C to +70°C)*

Ex nLc nAc [ia] IIC

(Ta = –40°C to +70°C)*

Cert. no.

Sira 08ATEX4130X

IECEx SIR 08.0032X

† (for guidance on the Gc, nLc & nAc marking)  * (see specification for operating temperature range)

FM CeRtIFICAtIoN INFoRMAtIoN

special Condition of Use - Factory Mutual (UsA & Canada)

1.  The Model 9468-ET shall be installed in compliance with the enclosure, mounting, spacing and 

segregation requirements of the ultimate application.

AteX & IeCex CeRtIFICAtIoN INFoRMAtIoN

The  following  information  is  in  accordance  with  the  Essential  Health  and  Safety  Requirements 
(Annex II) of the EU Directive 94/9/EC [the ATEX Directive - safety of apparatus] and is provided 
for those locations where the ATEX Directive is applicable.

General

a.  This equipment must only be installed, operated and maintained by competent personnel. Such 

personnel shall have undergone training, which included instruction on the various types of 
protection and installation practices, the relevant rules and regulations, and on the general 
principles  of  area  classification.  Appropriate  refresher  training  shall  be  given  on  a  regular 
basis. [See clause 4.2 of EN 60079-17].

b.  This  equipment  has  been  designed  to  provide  protection  against  all  the  relevant  additional 

hazards referred to in Annex II of the directive, such as those in clause 1.2.7.

c.  This  equipment  has  been  designed  to  meet  the  requirements  of  intrinsically  safe  electrical 

apparatus in accordance with EN 60079-0, EN 60079-11 and EN 60079-26.

Содержание 9468-ET

Страница 1: ...Instruction Manual INM9468 9468 ET 10 100Mb Ethernet Isolator ...

Страница 2: ...NSTALLATION 2 3 1 Protection 2 3 2 Mechanical mounting 2 3 4 Label marking 4 4 ENVIRONMENTAL 4 5 WASTE REMOVAL INFORMATION 4 6 ACCESSORIES 4 7 APPROVALS 5 8 FM CERTIFICATION INFORMATION 5 9 ATEX iecex CERTIFICATION INFORMATION 5 Measurement Technology Limited 2010 ...

Страница 3: ...nk 10Mb or Link 100Mb Established Safe Area UTP Tx Rx Activity Hazardous Area UTP Link 10Mb or Link 100Mb Established Hazardous Area UTP Tx Rx Activity Transparent operation 10 100Mbps Full Half Duplex with Auto Negotiation Supports IEEE 802 3 10Base T 100Base TX DIN rail mounting module Note PoEx is a simple adaptation of the IEEE 802 3af Power over Ethernet PoE standard to bring the benefits to ...

Страница 4: ...tructions contained here See also Sections 7 8 9 for approvals and important conditions of safe use 3 1 Protection The module requires mounting within an enclosure providing a degree of protection of at least IP6x in accordance with EN60529 and in a manner that does not impair the existing creepage and clearance distances The enclosure must also comply with the requirements of Clauses 7 and 8 of E...

Страница 5: ...X 2 RX 3 TX 4 5 6 TX 7 8 HAZARDOUS AREA 10 100 BASE T Ethernet RJ45 TX RX crossed MDI X Connector marked blue Pin No Function 1 RX 2 RX 3 TX 4 Supply 12V PoEx 5 Supply 12V PoEx 6 TX 7 Supply 0V PoEx 8 Supply 0V PoEx When supply has been connected to screw terminals 14 15 When connecting the Cat5e cable to another device a straight connected RJ45 cable is used a crossover cable is not required as t...

Страница 6: ...e Temperature 20 C 70 C Humidity 5 95 RH non condensing 5 WASTE REMOVAL INFORMATION The electronic equipment within must not be treated as general waste By ensuring that this product is disposed of correctly you will be helping to prevent potentially negative consequences for the environment and human health which could otherwise be caused by incorrect waste handling of this product For more detai...

Страница 7: ...Ex nLc nAc ia IIC Ta 40 C to 70 C Cert no Sira 08ATEX4130X IECEx SIR 08 0032X for guidance on the Gc nLc nAc marking see specification for operating temperature range 8 FM CERTIFICATION INFORMATION Special Condition of Use Factory Mutual USA Canada 1 The Model 9468 ET shall be installed in compliance with the enclosure mounting spacing and segregation requirements of the ultimate application 9 ATE...

Страница 8: ... the ic certified 9468 ET 10 100 Ethernet Isolator module does not satisfy Table 4 of EN 60079 0 2006 for equipment protection level Gc and could be a potential electrostatic charging hazard this must be taken into consideration during the installation of the modules b The nLc nAc certified 9468 ET 10 100 Ethernet Isolator module shall be installed in an ATEX Component Approved Ex e enclosure that...

Страница 9: ...e Cc cable Co psu Ci app Lc cable Lo psu Li app L R cable Lo Ro psu 12VDC IS Power Supply 9469 WLAN AP Bridge PoEx Supply for Port 3 Device Supply for 9466 PoEx for 9461 via Port 3 Supply for 9466 PoEx for 9465 via Port 5 Supply for 9465 PoEx not used Supply for 9466 PoEx Supply for Port 5 Device Supply for 9469 PoEx Supply for Port 1 Device PoEx Supply for Port 3 Device No PoEx No PoEx PoEx for 9...

Страница 10: ...ing of Typical Installation SIZE DWG NO REV A3 9400 System 4 SCALE SHEET 2 OF 2 CSL SCALE TITLE H G F E D C B A 8 7 6 5 4 3 2 1 H G F E D C B A 8 7 6 5 4 3 2 1 NOTE RJ45 ETHERNET PORTS ARE INTENDED FOR CONNECTION ONLY TO OTHER 9400 SERIES MODULES SHOWN ON THIS DRAWING With the exception of 9468 ET Safe Area port ...

Страница 11: ...9 INM9468 2 May 2010 ...

Страница 12: ...0092 Cinisello Balsamo MI Italy Tel 39 0 2 61802011 Fax 39 0 2 61294560 E mail info mtl inst it MTL Instruments KK MT Building 3F 2 7 5 Shiba Daimon Minato ku Tokyo Japan 105 0012 Tel 81 0 3 6430 3128 Fax 81 0 3 6430 3129 E mail sales mtlkk co jp Cooper Crouse Hinds Korea 12F Vision Tower 707 2 Yeoksam dong Gangnam gu Seoul 135 080 South Korea Tel 82 2 3484 6795 Fax 82 2 3484 6778 MTL Instruments ...

Отзывы: