The TP-P Series surge protector provides surge protection for field mounted process transmitters and is available
for 1/2’’NPT, 20mm ISO and G1/2” threaded conduit entries. The TP-P Series is certified and approved for use in
hazardous areas. More details of this are shown throughout this installation guide.
2
2..
IIM
MP
PO
OR
RT
TA
AN
NT
T S
SA
AF
FE
ET
TY
Y IIN
NF
FO
OR
RM
MA
AT
TIIO
ON
N
W
WA
AR
RN
NIIN
NG
G
N
N
IIn
n E
EE
Exx d
d /
/ e
exxp
pllo
os
siio
on
np
prro
oo
off a
ap
pp
plliic
ca
attiio
on
ns
s w
wh
he
erre
e e
exxp
pllo
os
siivve
e g
ga
as
se
es
s m
ma
ayy b
be
e p
prre
es
se
en
ntt,, tth
he
e llo
oo
op
p m
mu
us
stt b
be
e iis
so
olla
att--
e
ed
d b
be
effo
orre
e a
an
nyy E
EE
Exx d
d /
/ e
exxp
pllo
os
siio
on
np
prro
oo
off c
co
ovve
errs
s a
arre
e rre
em
mo
ovve
ed
d..
N
N
T
Th
he
e T
TP
P--P
P S
Se
erriie
es
s m
mu
us
stt b
be
e iin
ns
stta
alllle
ed
d,, o
op
pe
erra
atte
ed
d a
an
nd
d m
ma
aiin
ntta
aiin
ne
ed
d b
byy ttrra
aiin
ne
ed
d c
co
om
mp
pe
ette
en
ntt p
pe
errs
so
on
nn
ne
ell.. T
Th
he
e
T
TP
P--P
P u
un
niitt m
mu
us
stt n
no
ott b
be
e s
su
ub
bjje
ec
ctte
ed
d tto
o m
me
ec
ch
ha
an
niic
ca
all o
orr tth
he
errm
ma
all s
sttrre
es
ss
se
es
s iin
n e
exxc
ce
es
ss
s o
off tth
ho
os
se
e o
ou
uttlliin
ne
ed
d iin
n tth
he
e
A
AT
TE
EX
X s
sp
pe
ec
ciiffiic
ca
attiio
on
ns
s..
N
N
T
Th
he
e T
TP
P--P
P rra
an
ng
ge
e m
mu
us
stt n
no
ott b
be
e iin
ns
stta
alllle
ed
d iin
n a
an
n a
arre
ea
a w
wh
he
erre
e iitt m
ma
ayy b
be
e a
atttta
ac
ckke
ed
d b
byy a
ag
gg
grre
es
ss
siivve
e s
su
ub
bs
stta
an
nc
ce
es
s..
N
N
W
Wh
he
erre
e h
ha
azza
arrd
do
ou
us
s a
arre
ea
a p
prro
otte
ec
cttiio
on
n c
co
on
nc
ce
ep
ptts
s a
arre
e b
be
eiin
ng
g a
ap
pp
plliie
ed
d tth
he
e p
prro
od
du
uc
ctt m
mu
us
stt b
be
e iin
ns
stta
alllle
ed
d iin
n a
ac
cc
co
orr--
d
da
an
nc
ce
e w
wiitth
h tth
he
e rre
eq
qu
uiirre
em
me
en
ntts
s o
off tth
he
e E
EC
C T
Tyyp
pe
e E
Exxa
am
miin
na
attiio
on
n g
gu
uiid
de
elliin
ne
es
s iin
n tth
hiis
s d
do
oc
cu
um
me
en
ntt..
N
N
T
Th
he
e ‘‘ttrra
an
ns
sm
miitttte
err’’ m
mu
us
stt b
be
e e
elle
ec
cttrriic
ca
allllyy iis
so
olla
atte
ed
d d
du
urriin
ng
g tth
he
e iin
ns
stta
alllla
attiio
on
n p
prro
oc
ce
ed
du
urre
e..
N
N
A
Allll iin
ns
stta
alllla
attiio
on
n a
an
nd
d m
ma
aiin
ntte
en
na
an
nc
ce
e m
mu
us
stt b
be
e c
ca
arrrriie
ed
d o
ou
utt iin
n a
ac
cc
co
orrd
da
an
nc
ce
e w
wiitth
h a
allll a
ap
pp
prro
op
prriia
atte
e iin
ntte
errn
na
attiio
on
na
all,,
n
na
attiio
on
na
all a
an
nd
d llo
oc
ca
all s
stta
an
nd
da
arrd
d c
co
od
de
es
s o
off p
prra
ac
cttiic
ce
e a
an
nd
d s
siitte
e rre
eg
gu
ulla
attiio
on
ns
s a
an
nd
d iin
n a
ac
cc
co
orrd
da
an
nc
ce
e w
wiitth
h tth
he
e iin
ns
sttrru
uc
c--
ttiio
on
ns
s c
co
on
ntta
aiin
ne
ed
d w
wiitth
hiin
n tth
hiis
s m
ma
an
nu
ua
all..
3
3.. IIN
NS
ST
TA
AL
LL
LA
AT
TIIO
ON
N
3
3..1
1 Disconnect and isolate existing circuit.
Select conduit entry to be used for installa-
tion, and remove any blanking plug. Note:
If direct installation onto the apparatus itself
is impossible e.g. because all conduit entries
are in use already, an external junction box
or conduit hub can be used. The TP-P Series
s supplied with 300mm leads, which should
be sufficient for them to reach the transmit-
ter terminals from a junction box. If these
leads are not long enough then use supple-
mentary terminals and wiring. Installation
should be within 1m of, and bonded to, the
transmitter.
3
3..2
2 Ensure that the TP-P body thread matches
the conduit entry. Thread types are not interchangeable, but adapters may be used where necessary.
For explosionproof (EEx d) installations, only certified or approved adapters are permitted.
3
3..3
3 Remove apparatus terminal housing cover.
3
3..4
4 Insert connecting wires into apparatus body and start threading unit into conduit entry using moderate
hand-force, with lubricants as necessary.
3
3..5
5 Tighten fully (hand-tight plus 1/2 turn of 23mm A/F spanner). The steel body of the TP-P device is not
used as part of the electrical circuit, therefore sealing of the thread with PTFE tape or other sealing com
pounds will not affect the performance of the TP-P device.
N
No
otte
e:: In Explosionproof (EEx d) applications, sealing of the thread is not permitted – the TP-P should be treated in
the same way as any other cable gland/hub into similar equipment.
3
3..6
6 For effective protection, the leads of the TP-P should be as short as possible. Before wiring to the trans-
mitter terminals, cut the leads to the appropriate length and strip back 10mm of insulation. Do not try
to coil excess lengths of cable into the transmitter housing as this will degrade the protection given by
the surge protector.
3
3..7
7 Connect the flying leads to the terminals indicated below;-
N
No
otte
e:: The protection circuit needs to be connected in series with the transmitter 4-20mA current loop.
+
+vve
e
--vve
e
E
Ea
arrtth
h/
/G
Grro
ou
un
nd
d
TP-P48 & TP-P32
Red
Black
Green/Yellow
F
Fiig
gu
urre
e 1
1 Connection detail for typical process transmitter.
3
3..8
8
Ensure that all connections are tight, particularly the earth bonding connection, which is likely to be
via a stud within the apparatus terminal housing.
3
3..9
9
Refit apparatus terminal housing cover.
3
3..1
10
0 The field wiring is next connected to the provided three position plug. Cve to the terminal
marked “+”, Connect –ve to the terminal marked “-“, and connect the ground wire or shield (if present)
to the terminal marked “G”. Wire strip length is 5mm (0.196”).
3
3..1
11
1 Using a long nose pliers, insert the plug into the socket inside the TP-P body. This connector must be
orientated correctly for full seating and connectivity.
3
3..1
12
2 Complete the installation by mounting an appropriate fitting and/or conduit for the location used.
3
3..1
13
3 Reconnect circuit and test system to verify operational status.
4
4..
E
EA
AR
RT
TH
HIIN
NG
G /
/ G
GR
RO
OU
UN
ND
DIIN
NG
G
W
WA
AR
RN
NIIN
NG
G:: T
Th
he
e e
en
nc
cllo
os
su
urre
e d
do
oe
es
s n
no
ott p
prro
ovviid
de
e a
an
n e
exxtte
errn
na
all o
orr iin
ntte
errn
na
all c
co
on
nn
ne
ec
cttiio
on
n ffo
orr e
ea
arrtth
hiin
ng
g o
orr g
grro
ou
un
nd
diin
ng
g
tth
he
e e
en
nc
cllo
os
su
urre
e.. IItt iis
s tth
he
e u
us
se
err’’s
s rre
es
sp
po
on
ns
siib
biilliittyy tto
o p
prro
ovviid
de
e a
ad
de
eq
qu
ua
atte
e e
ea
arrtth
h c
co
on
nttiin
nu
uiittyy vviia
a tth
he
e m
mo
ou
un
nttiin
ng
g a
arrrra
an
ng
ge
e--
m
me
en
ntts
s ffo
orr a
allll llo
oc
ca
attiio
on
ns
s a
an
nd
d a
allll p
prro
otte
ec
cttiio
on
n m
me
etth
ho
od
ds
s..
The TP-P earth wire (Green/Yellow) should be connected to the earth terminal or stud usually provided inside
the transmitter housing. In the unlikely event that no such stud exists, make the connection to a structural
mounting part, such as a terminal block fixing screw.
5
5..
M
MA
AIIN
NT
TE
EN
NA
AN
NC
CE
E
At intervals of not more than one year (more frequently for particularly harsh environments) visually check the
installation and ensure that:
i) Device and/or enclosure is firmly attached to mounting
ii) There are no signs of external damage or corrosion
iii) Interconnecting cables are not frayed or otherwise damaged
iv) All connections are properly made with clear labelling
If this unit suffers damage send back to MTL Surge Technologies for evaluation which should only be carried
out by MTL Surge Technologies. This product is not field repairable.
6
6..
A
AP
PP
PR
RO
OV
VA
AL
LS
S
In hazardous locations check the marking on the device to ensure that it is appropriate for the application. Mark
the appropriate box (figure 2) to indicate the type of protection being utilised. For marking use a punch mark.
The product range has been designed to meet the fault tolerant requirements of Electrical Apparatus for
Category ‘ia’. Entity parameters: See Certificate number Baseefa06ATEX0034X
A
AT
TE
EX
X S
Sp
pe
ec
ciia
all C
Co
on
nd
diittiio
on
ns
s ffo
orr S
Sa
affe
e U
Us
se
e::
The following relate to installations to Baseefa06ATEX0034X:
1. The apparatus is to be installed such that the flying leads are afforded a degree of protection of at least
IP54.
2. Although all versions of the TP-P Series Surge Protection Devices meet the 500V test to the metal case
the electrical circuit within the Surge Protection Devices are not capable of withstanding the 500V voltage
withstand test for one minute without breakdown to the Green/Yellow wire. This must be taken into con-
sideration in any installation.
3. These devices are not provided with an external connection facility for an earthing or bonding conductor. It
is the user’s responsibility to ensure adequate earth continuity via the mounting arrangement.
4. This apparatus is also afforded Flameproof Certification to Baseefa06ATEX0035X and is dual marked. It
is the user’s responsibility to determine the relevant protection concept and to permanently mark the