The meaning of parameters used by SVGAUTL.EXE are explained below:
Syntax:
>SVGAUTL [/D:mode_no] [/F0:n0] [/F1:n1] [/F2:n2] [/F3:n3] [/PA:ta] [/PB:tb]
where
/D: Set the Video Mode to be mode_no which is a hex number.
For example:
Set 1024x768 256 color graphic mode.
>SVGAUTL/D:38<Enter>
/F0: For 640x480, set frame rate to be n0 Hz.
Three available frame rates are 60, 72, and 75Hz.
For example: Set 640X480 graphic mode with 60Hz frame rate
>SVGAUTL/F0:60<Enter>
/F1: For 800x600, set frame rate to be n1 Hz.
Four available frame rates are 56,60,72, and 75 Hz.
For example: Set 800x600 graphic mode with 72Hz frame rate.
>SVGAUTL/F1:72<Enter>
/F2: For 1024x768, set frame rate to be n2 Hz.
Four available frame rates are 87 (Interlace), 60, 70, and 75Hz.
For example: Set 1024x768 graphic mode with 60Hz frame rate.
>SVGAUTL/F2:60<Enter>
/F3: For 1280x1024, set frame rate to be n3 Hz.
Two available frame rates are 87 (Interlace) and 60Hz.
For example: Set 1280x1024 graphic mode with 60Hz frame rate.
>SVGAUTL/F3:60<Enter>
/PA:Set Standby Timer to be ta minutes. (0< ta < 15 min.)
For example: Set Standby Timer be 5 minutes.
>SVGAUTL/PA:5<Enter>
/PB:Set Suspend Timer to be tb minutes. (0< tb < 15min.)
For example: Set Suspend Timer be 5 minutes.
>SVGAUTL/PB:5<Enter>
Note:
(1) Suspend Time is "ta + tb"(i.e. standby time + suspend time)
(2) The timers are not very accurate
_______________________________________________________________
6- 3
【
【
【
【
6
】
】
】
】
_________________________________
Autodesk ADI 4.2 - Protected Mode
General Description