background image

24

RailKing PCC Street Car Operating Manual

TROUBLE SHOOTING 

PROTOSOUND

®

PROBLEMS

  Although ProtoSound® has been designed and engineered for ease of use,
some questions may arise during initial operation.  The following table
should answer most questions. If you find that your problem can’t be
resolved with this manual, contact  MTH ProtoSound® Electronics (9693-A 
Gerwig Lane, Columbia, MD 21046,  410-381-2580) for additional
assistance.

HORN PROBLEMS

REMEDY

The horn seems distorted at low voltages.

Your battery may be undercharged or dead.  Try
recharging the battery as explained in the battery
sections.

When I press the whistle button, the bell comes on
instead.

You are trying to operate the horn in neutral.  The horn 
will only operate in Forward or Reverse unless you
program ProtoSounds through Feature 25.  See the
instructions in the section entitled “Using RESET to
Program ProtoSounds”.  The transformer leads may
be wired to the track backwards.  Reverse the lead
connections to the transformer.

I can’t get the horn to blow when I press the whistle
button.

You may be pressing the whistle button too quickly.
Most older AC transformers contain a two--step
whistle button that releases a DC signal onto the track. 
It is this DC signal that tells the horn to blow.
However, because the signal is weaker when the
whistle button is depressed fully, the ProtoSound
circuit may not recognize the signal.  Try pressing the
whistle button slower, taking approximately 1 second
to fully depress the button.

BELL PROBLEMS

REMEDY

When I press the whistle button to activate the bell, the 
horn sounds.

You are trying to ring the bell in Forward or Reverse.
The bell only operates in Neutral unless you have
programmed ProtoSounds to recognize a separate
bell button.

When I press the whistle button to activate the bell, I
arm the coupler.

Reduce the voltage on the transformer before pressing 
the whistle button to activate the bell.  The bell will
only come on at 8 volts or less.

When I press the whistle button to activate the bell, the 
bell only rings once.

You are trying to ring the bell in RESET instead of
neutral.  Interrupt the power twice to enter Neutral, set
the voltage at 8 volts or less and press the whistle
button to activate the bell.

I can’t get the bell to ring when I press the whistle
button.

You may be pressing the whistle button too quickly.
See the 3rd remedy in the horn section above.

The bell won’t work with a separate bell button.

ProtoSounds must be programmed in order for a
separate bell button to function.  Enter RESET
function number 20 (see the section entitled “Using
RESET to Program ProtoSounds”) and press the
whistle button until the bell sounds two dings.  Simply
turn the throttle off and then on again to lock in the
new setting.

Содержание PCC Street Car

Страница 1: ...t car is equipped with a DCRU electronic reverse unit and can be optionally equipped with the ProtoSound Digital Sound and train control system which contains several deluxe features that are simple a...

Страница 2: ...14 Programming For A Separate Bell Button Controller 15 Programming For Squeaking Brake Operation 16 Programming For Horn In Neutral Operation 17 Programming For TAS Operation 17 Activating Reverse U...

Страница 3: ...prototypical speeds Once the engine is placed on the track the throttle on the transformer can be advanced You will see that only the car s lights come on and that only two dings of the ProtoSound bel...

Страница 4: ...verse unit begins in RESET or what seems like a neutral state Power must be interrupted again to get the car to enter the forward state It is this first RESET state that gives ProtoSound its unique re...

Страница 5: ...leave RESET your car will operate normally in all the direction states of forward neutral and reverse HORN OPERATION Your RailKing ProtoSound equipped street car features a digital recording of a PCC...

Страница 6: ...pushing the button on to start the bell sound the operator must push and release the bell button quickly Failure to release the button quickly will activate the Trolley Announcement feature which is...

Страница 7: ...turn the throttle off quickly the brake sounds will likely continue playing even though the car has come to a complete stop This annoying effect can be eliminated by simply practicing with the brake...

Страница 8: ...voltages or become silent when power from the transformer is shut off the battery charge may be low Before replacing the battery you should put the engine in NEUTRAL and leave the transformer throttl...

Страница 9: ...imulate the arrival disembarking embarking and departure of a PCC stop The sounds include the PCC driver announcing the stop and the upcoming stop passenger disembarking and embarking sounds driver to...

Страница 10: ...he operator can expect to hear a variety of different sounds including the driver asking the passengers to move to the back to have their fare ready as well as the sounds of footsteps general passenge...

Страница 11: ...by pressing the bell button In short the insulated track section and diode are acting like a bell button Whenever the car runs through the insulated section it will receive the negative DC signal and...

Страница 12: ...T position Tip 2 You do not have to be in the forward state to utilize TAS For example if you activate the TAS feature while in reverse and interrupt the throttle to enter neutral you will be entering...

Страница 13: ...ad empire s motive power never before seen in model railroading Each programmable feature can be accessed whenever your car is in the RESET state as described earlier on page 4 By following the instru...

Страница 14: ...6 To access the feature advance the transformer throttle to put the engine in RESET Move the throttle up and down as described on page 5 6 times After you hear the clank and clink indicating that you...

Страница 15: ...he sectionUsing RESET To Program ProtoSounds on page 13 Once in Feature 20 press the whistle button and wait for the module to sound a bell ding s Continue pushing the whistle button until the module...

Страница 16: ...es are activated for full time operation repeat the above procedure but keep pushing the whistle button until the module only responds with two bell dings PROGRAMMING FOR HORN IN NEUTRAL OPERATION If...

Страница 17: ...whistle button and wait for ProtoSounds to sound a bell ding s Continue pressing the whistle button on and off until ProtoSounds sounds one bell ding s signifying that the TAS feature has been turned...

Страница 18: ...an go to RESET Feature 18 to reset all ProtoSound features back to their original factory defaults including Remote Lockout Control RESETTING ALL PROTOSOUND OPTIONS TO FACTORY DEFAULTS ProtoSounds is...

Страница 19: ...e button WHILE THE HORN IS BLOWING TURN THE THROTTLE OFF AND THEN LET GO OF THE WHISTLE BUTTON After about one second you will hear a short horn blast QUICKLY TURN THE THROTTLE BACK ON AGAIN Your engi...

Страница 20: ...make any difference on how the lockout function operates you may hear one of the three different NEUTRAL activated sounds To unlock the engine from the NEUTRAL position follow the process to unlock t...

Страница 21: ...ry and shouldn t need additional grease until after 50 hours of operation or one year whichever comes first Grease cannot be added to the internal gearing until the body is removed from the chassis wh...

Страница 22: ...may arise a time where they will need to be replaced Should this occur you will need to remove the power truck from the chassis in order to slip the new tire over the grooved drive wheel We suggest y...

Страница 23: ...ion section on the preceding pages Once the cab has been removed from the chassis gently twist and push the bulb to unlock it from its lamp housing Once unlocked the bulb will pull out of the socket I...

Страница 24: ...use the signal is weaker when the whistle button is depressed fully the ProtoSound circuit may not recognize the signal Try pressing the whistle button slower taking approximately 1 second to fully de...

Страница 25: ...l hear the TAS sounds because setting the motor volume only controls the sound of the car itself All other sounds including TAS the horn and bell will continue to play at the volume level set by the m...

Страница 26: ...lower movement as you interrupt the power in RESET and enter the Forwaard Phase BRAKE SOUND PROBLEMS REMEDY When the transformer is throttled down the sounds won t play The brake features has not been...

Страница 27: ...utomatically comes on TAS has a built in command to turn on the bell when the system enters and leaves TAS When leaving TAS the bell will ring 2 times before turning off Whenever TAS is enabled pressi...

Страница 28: ...v 300 Watt Electronic Cab 1 Powerma st er A U 0 18v 135V A Electronic Dallee Hostler Left Terminal Right Terminal Lionel LW A U 8 18v 75 Watt Standard Lionel KW A or B U 6 20v 190 Watt Standard MRC Te...

Страница 29: ...and press and hold the transformer whistle button until you hear a soft warbled bell sound RESET OPERATION DEFAULT CLANKS CLINKS 6 Engine Volume Full Volume 1 Clank 1 Clinks 10 RESERVED 2 Clanks 0 Cl...

Страница 30: ...30 RailKing PCC Street Car Operating Manual...

Страница 31: ...31 RailKing PCC Street Car Operating Manual...

Страница 32: ...one number Return Authorization number a copy of your sales receipt and a full description of the problem must be included to facilitate the repairs Please include the description regardless of whethe...

Отзывы: