background image

RK FP45 Diesel Engine with PS-2

20

FYS/PSA

Remedy

Once in FYS/PSA, the engine 
doesn’t go into reverse.

When the FYS/PSA enters its last 
sequence the bell automatically 
comes on.

When FYS/PSA is enabled, 
pressing the whistle and bell 
buttons has no effect.

I push the direction button but the 
next sound clip in the sequence 
does not play or the engine does 
not come out of FYS/PSA after 
fourth press of the direction 
button.

So that FYS/PSA effects can be 
as realistic as possible, Proto-
Sound 2.0 disables the reversing 
unit whenever FYS/PSA is 
enabled.  This way the engine 
remains still at its stop as the 
operator cycles through the 
FYS/PSAsequences.

FYS/PSA is programmed to start 
ringing the bell at that point.  After 
approximately 12 seconds it will 
automatically turn off.

Because FYS/PSA must control 
various effects in each sequence, 
Proto-Sound 2.0 takes control of 
these sound effects until you exit 

Each FYS/PSA clip must play for 
approx. 30 seconds before 
FYS/PSA will advance to the next 
step in the FYS/PSA cycle.  Wait 
at least 30 seconds in each 
FYS/PSA sound clip before 
pressing the direction button.

Содержание 30-2907-1

Страница 1: ...track system including M T H s RealTrax or ScaleTrax or traditional tubular track It is also compatible with most standard AC transformers See page 22 for a complete list of compatible transformers a...

Страница 2: ...91 263 6 604 641 6 619 594 6 624 537 6 655 640 2009 M T H Electric Trains Columbia MD 21046 CAUTION ELECTRICALLY OPERA TED PRODUCT WARNING When using electrical products basic safety precautions shoul...

Страница 3: ...1 Do not over oil Use only a drop or two on each pivot point Checking the Battery You may find if your locomotive was built several months before you set it up that the rechargeable battery has run d...

Страница 4: ...se not to add smoke fluid or have already added fluid but choose to run smoke free turn off the smoke unit by turning the smoke unit conrol fully counter clockwise Failure either to add fluid to the s...

Страница 5: ...ne will maintain the speed you set after you release the throttle until you turn it again to change the voltage and speed Bell To sound the bell in an engine equipped with a bell firmly press and rele...

Страница 6: ...of all sounds made by this engine turn the manual volume control shown below clockwise to increase the volume and counter clockwise to decrease the volume RK FP45 Diesel Engine with PS 2 6 Figure 4 M...

Страница 7: ...quickly but firmly tap the Bell button once followed by 2 quick taps of the Horn Whistle button while the engine is moving Tap the buttons quickly but allow approximately second between each press Pre...

Страница 8: ...l once you have stopped the engine to run the FYS PSA Otherwise the engine without FYS PSA will begin vibrating on the track as its motors strain to move the train since they cannot be automatically d...

Страница 9: ...hen quickly tap the transformer s horn whistle button one time then quickly tap the Bell button two times allowing approximately second to lapse between each quick button press Repeat the 1 horn whist...

Страница 10: ...asts will indicate that the engine has made the change Automatic Sounds Certain Proto Sound 2 0 sound effects automatically play in programmed conventional mode conditions Squealing Brakes play any ti...

Страница 11: ...ews as seen in Figure 5 and lifting the cab from the chassis 2 Once the cab is removed remove the trucks by unscrewing the black Phillips motor mount screw located on the underside of the drive trucks...

Страница 12: ...enance Kit 30 50010 or denatured not rubbing alcohol and a clean rag Unplug the transformer and wipe the rails of the track turning the rag frequently to ensure that you are using clean cloth on the r...

Страница 13: ...old tire has been completely removed from the groove in the drive wheel using a razor blade or small flathead screwdriver to pry away any remains 2 Slip the new tire onto the wheel You may find it us...

Страница 14: ...ved locate burned out light bulb s Carefully remove bulb s from mounting Disconnect light bulb harness from main harness wire Replacement bulb harnesses are available directly from the M T H Parts dep...

Страница 15: ...re a number of ways you can do this Leave the engine in neutral with track voltage at 10 12 volts for 6 7 hours so the battery can fully recharge if your engine has a smoke unit be sure it is turned o...

Страница 16: ...f smoke produced turn the smoke unit volume control clockwise to increase the amount of smoke or counter clockwise to reduce the amount see Fig 3 on page 4 If you choose not to add smoke fluid or have...

Страница 17: ...ent parts and wick replacement instructions are available directly from the M T H Parts Department Order online www mth railking com e mail parts mth railking com Fax 410 423 0009 Phone 410 381 2500 M...

Страница 18: ...l button The bell won t work on a separate bell button When I try to fire the coupler FYS starts The Proto Coupler won t let the engine uncouple on the fly The coupler does not fire or stay coupled Wh...

Страница 19: ...engine is locked into the neutral position Follow the procedure in the Lock into a Direction section Engine speed must be below 10 scale mph approx 10 volts or less in conventional mode Proto Sound 2...

Страница 20: ...realistic as possible Proto Sound 2 0 disables the reversing unit whenever FYS PSA is enabled This way the engine remains still at its stop as the operator cycles through the FYS PSAsequences FYS PSA...

Страница 21: ...button push stops all Proto Sound 2 0 trains but does not turn off the power One Touch Global Mute UnMute Single button mutes or unmutes all DCS controlled locomotives user defined actions including s...

Страница 22: ...andard Lionel 1063 Lionel LW Powermaster U A U A U A 8 17v 8 18v 8 18v 60 Watt 75 Watt 135VA Standard Standard Electronic All Trol Left Terminal Right Terminal 0 24v 300 Watt Electronic Dallee Hostler...

Страница 23: ...refully before returning any merchandise for service Authorized M T H Service Centers are independently owned and operated and are not agents or representatives of M T H Electric Trains M T H assumes...

Отзывы: