background image

Troubleshooting Proto-Sound® Problems

Although Proto-Sound 2.0 has been designed and engineered for ease of  use,
 you may have some questions during initial operation.  The following table
 should answer most questions.  If your problem cannot be resolved with this 
table, contact M.T.H. for assistance (www.mth-railking.com, e-mail: parts@mth-
railking.com,Fax:  410-423-0009, Phone: 410-381-2500, Mail: 7020 Columbia 
Gateway Drive, Columbia MD 21046-1532, ). 

SW-8 & SW-9 Diesel Engine with PS-2

15

Starting Up

Whistle/Horn

Bell

Coupler

Remedy

Remedy

Remedy

Remedy

Remedy

When I first turn the power on, the 
engine will not begin to run.  I 
have to turn the throttle off and 
then on again to get the engine to 
operate.

When I press the whistle/horn 
button, the bell comes on instead.

I can’t get the horn to blow when I 
press the whistle button.

I can’t get the bell to ring when I 
press the bell button.

The bell won’t work on a separate 
bell button.

When I try to fire the coupler, FYS 
starts.

The Proto-Coupler won’t let the 
engine uncouple on the fly.

The coupler does not fire or stay 
coupled.

When I press the whistle button, 
the bell sounds.

Reverse the transformer leads.

You may be pressing the button 
too quickly. Try pressing the 
whistle/horn button more slowly, 
taking approximately one full 
second to fully depress the button.

You may be pressing the button 
too quickly. Try pressing the bell 
button more slowly, taking 
approximately one full second to 
fully depress the button.

Reverse the transformer leads.

Check the wiring of the separate 
button.

You are waiting too long between 
whistle button presses.

Try lubricating the coupler knuckle 
with a dry graphite lubricant. Do 
NOT use oil.

The coupler needs to be cleaned.  
Wipe with denatured alcohol (not 
rubbing alcohol) and let dry.

This is normal behavior.  To 
prevent accidental high-speed 
start-ups, Proto-Sound 2.0 is 
programmed to start up in neutral 
anytime track power has been 
turned off for several seconds.  

Содержание 30-2824-1

Страница 1: ...nal O 31 Gauge track system including M T H s RealTrax or ScaleTrax or traditional tubular track It is also compatible with most standard AC transformers See page 19 for a complete list of compatible...

Страница 2: ...63 6 604 641 6 619 594 6 624 537 6 655 640 2008 M T H Electric Trains Columbia MD 21046 CAUTION ELECTRIC TOY WARNING When using electrical products basic safety precautions should be observed includin...

Страница 3: ...not over oil Use only a drop or two on each pivot point Checking the Battery You may find if your locomotive was built several months before you set it up that the rechargeable battery has run down a...

Страница 4: ...e will maintain the speed you set after you release the throttle until you turn it again to change the voltage and speed Bell To sound the bell in an engine equipped with a bell firmly press and relea...

Страница 5: ...ume of all sounds made by this engine turn the manual volume control shown below clockwise to increase the volume and counter clockwise to decrease the volume SW 8 SW 9 Diesel Engine with PS 2 5 Manua...

Страница 6: ...ut firmly tap the Bell button once followed by 2 quick taps of the Horn Whistle button while the engine is moving Tap the buttons quickly but allow approximately second between each press Press the Di...

Страница 7: ...el once you have stopped the engine to run the FYS PSA Otherwise the engine without FYS PSA will begin vibrating on the track as its motors strain to move the train since they cannot be automatically...

Страница 8: ...then quickly tap the transformer s horn whistle button one time then quickly tap the Bell button two times allowing approximately second to lapse between each quick button press Repeat the 1 horn whis...

Страница 9: ...lasts will indicate that the engine has made the change Automatic Sounds Certain Proto Sound 2 0 sound effects automatically play in programmed conventional mode conditions Squealing Brakes play any t...

Страница 10: ...bove and lifting the cab from the chassis 2 Once the cab is removed remove the trucks by unscrewing the black Phillips motor mount screw located on the underside of the drive trucks see above 3 Once t...

Страница 11: ...ance Kit 30 50010 or denatured not rubbing alcohol and a clean rag Unplug the transformer and wipe the rails of the track turning the rag frequently to ensure that you are using clean cloth on the rai...

Страница 12: ...ve wheel using a razor blade or small flathead screwdriver to pry away any remains 2 Slip the new tire onto the wheel You may find it useful to use two small flathead screwdrivers to stretch the tire...

Страница 13: ...nd Greasing Instructions section on pg 10 of this manual Once the body has been removed locate burned out light bulb s Carefully remove bulb s from mounting Disconnect light bulb harness from main har...

Страница 14: ...at the end of the 15 minute test charge it is time to replace the battery Available through M T H Parts Item No 50 1024 AA NiCad Proto Sound Battery See photos below for battery removal and installat...

Страница 15: ...ll button The bell won t work on a separate bell button When I try to fire the coupler FYS starts The Proto Coupler won t let the engine uncouple on the fly The coupler does not fire or stay coupled W...

Страница 16: ...into the neutral position Follow the procedure in the Lock into a Direction section Engine speed must be below 10 scale mph approx 10 volts or less in conventional mode Proto Sound 2 0 volume is set t...

Страница 17: ...s realistic as possible Proto Sound 2 0 disables the reversing unit whenever FYS PSA is enabled This way the engine remains still at its stop as the operator cycles through the FYS PSAsequences FYS PS...

Страница 18: ...button push stops all Proto Sound 2 0 trains but does not turn off the power One Touch Global Mute UnMute Single button mutes or unmutes all DCS controlled locomotives user defined actions including...

Страница 19: ...ndard Lionel 1063 Lionel LW Powermaster U A U A U A 8 17v 8 18v 8 18v 60 Watt 75 Watt 135VA Standard Standard Electronic All Trol Left Terminal Right Terminal 0 24v 300 Watt Electronic Dallee Hostler...

Страница 20: ...refully before returning any merchandise for service Authorized M T H Service Centers are independently owned and operated and are not agents or representatives of M T H Electric Trains M T H assumes...

Отзывы: