MTHTrains 260E Скачать руководство пользователя страница 3

3

260E Steam Engine Contemporary 

QUICK START - BASIC OPERATION

  The MTH 260e contains state-of-the art electronics with several built-in
automatic features for incredibly realistic operation. Despite these advanced 
features, the 260e is easy to operate with any compatible standard AC
transformer (see the compatibility chart on page 34).  All models are
equipped with an operating smoke system that 

should be primed with

smoke fluid before operating

.  Adding 15 - 20 drops of fluid through the

smoke stack should be sufficient.  

If you choose to not prime the units

 

with 

fluid

,  

turn the smoke unit switch located under the trailing truck to the

OFF position

.  This will prevent any damage from occurring to the smoke

unit when running the engine without a primed smoke unit. For more
information see the section on page 4 on Smoke Unit operation.

  The 260e model is controlled by a
ProtoSound® DCRU® electronic reverse
unit.  The reverse unit operates in the same
manner that all reverse units function by
using forward, neutral and reverse states
that are entered each time the throttle is
turned on and off or by using the
transformer direction switch (if so
equipped).

  The reverse unit is designed to ignore dirty track, dead spots on switches
or minor short circuits without disrupting the engine operation, even at

slow, prototypical speeds. Before
the engine can be operated however, 
the reverse unit plug that extends out 
of the tender must be inserted into
the receptacle at the back of the
boiler cab as seen in Figure 1.  Once 

the plug is inserted, the throttle on the transformer can be advanced. You
will see that only the engine’s lights come on and that on ProtoSound
equipped engines, two dings from the sound system will chime followed by
the steam compressor pump sounds.  The engine does not run.  This is
known as the RESET state and is explained in more detail beginning on
Page 5.  The ProtoSound® DCRU® will not power the motor until the
throttle is turned OFF and then ON again.  At this point, the engine will
now function just like any other electronic or mechanical E-unit. 

Plug Tender Plug Into
Boiler Socket At Back Of Cab

Figure 1:  Plugging in the tender harness

RESET

Neutral

Reverse

Neutral

Forward

Figure 2:  ProtoSound® DCRU® Cycle Phases

Содержание 260E

Страница 1: ...ble AC transformer see page 34 for a complete list of compatible transformers and wiring instructions and is completely compatible with most other 3 rail locomotives rolling stock and accessories The...

Страница 2: ...AM PROTOSOUNDS 18 Entering RESET Options 18 Setting The Engine Volume 19 Programming For A Separate Bell Button Controller 20 Programming For Squeaking Brake Operation 20 Programming For Whistle In Ne...

Страница 3: ...everse states that are entered each time the throttle is turned on and off or by using the transformer direction switch if so equipped The reverse unit is designed to ignore dirty track dead spots on...

Страница 4: ...ior engine components When the smoke output begins to diminish while running the engine an additional 10 15 drops of smoke fluid should be added or the smoke unit switch should be turned off When stor...

Страница 5: ...o the track the reverse unit begins in RESET or what seems like a neutral state Power must be interrupted again to get the locomotive to enter the forward state It is this first RESET state that gives...

Страница 6: ...ive using any of these programmable features simply leave RESET and wait 2 2 seconds before interrupting the power to put the engine in forward After you leave RESET your engine will operate normally...

Страница 7: ...voltage will arm the ProtoCoupler and press the whistle button The bell should begin chiming To turn the bell off press the whistle button again If you want to keep the bell on while running the engin...

Страница 8: ...voltage is reduced from high to low Some practice may be required to synchronize the playing of the brake sounds with the movement of the engine It is not uncommon for the engine to stop before the b...

Страница 9: ...e to keep the engine moving while the brake sounds play and then turning the throttle off just as the sounds stop Remember that once you stop the engine you should turn the throttle to the off positio...

Страница 10: ...departure messages passenger disembarking and embarking sounds conductor voices and general train station ambient sounds Each is described in more detail in the following sections ACTIVATING PASSENGER...

Страница 11: ...whistle button To activate the feature turn on the transformer throttle and get your engine into the neutral position not RESET Once in neutral set the transformer throttle at 8 volts or less and pre...

Страница 12: ...rection it arrived The following operator controlled events control PFA s actions and sounds Event 1 Forward While the locomotive is running in forward or reverse PFA is activated by the operator push...

Страница 13: ...histling for a taxi In addition several highlight or foreground sounds play including more conductor voices saying watch your step have a nice day and baggage to the right Event 3 Reverse The operator...

Страница 14: ...ase Event 5 Forward The operator now interrupts the transformer throttle again to enter the next reverse unit phase forward PFA confirms to the operator that it has entered the forward phase by playin...

Страница 15: ...ith ProtoSounds or PFA If the engine isn t equipped with PFA the only thing to remember is that you not turn up the transformer throttle very high when entering the reverse state found in Event 3 If t...

Страница 16: ...ody is a special NiCad 7 cell 8 4v battery NOT the 6 cell 7 2v battery found in most convenience stores The 6 cell NiCad is NOT recommended for use with ProtoSound applications The battery is continua...

Страница 17: ...chassis See Fig 5 below allows you to control all the sounds in the system and a remote control RESET option Option 6 allows you to control the volume level of the engine sounds remotely from the tran...

Страница 18: ...dvance one feature at a time through the available options An air release sound is heard each time the throttle is advanced In addition there are special sounds to tell you what RESET position you are...

Страница 19: ...you 50 volume pushing it a third time will give you 25 volume and pushing it a fourth time will give you no sound The microprocessor will immediately play the sound level each time the whistle button...

Страница 20: ...rammed for a bell button Simply turn the throttle off and then on again to Lock In the new setting To reset the computer to its original factory default setting no separate bell button operation repea...

Страница 21: ...to blow your horn when your engine is in neutral you will need to program ProtoSounds to do so as the factory setting only allows the horn to blow in forward or reverse To do this enter RESET and go...

Страница 22: ...18 Once in Feature 28 press the transformer whistle button and wait for ProtoSounds to sound a bell ding s Continue pressing the whistle button on and off until ProtoSounds sounds two bell dings signi...

Страница 23: ...y defaults including Remote Lockout Control RESETTING ALL PROTOSOUND OPTIONS TO FACTORY DEFAULTS ProtoSounds is equipped with a RESET feature Feature 18 that resets all programmable options back to th...

Страница 24: ...THEN LET GO OF THE WHISTLE BUTTON After about one second you will hear a short horn blast QUICKLY TURN THE THROTTLE BACK ON AGAIN Your engine is now locked into Forward or Reverse and it will remain...

Страница 25: ...ler firing depending on the transformer throttle voltage settings prior to the user s attempt to lock out the engine Remember the whistle doesn t blow in NEUTRAL unless you programmed it to do so usin...

Страница 26: ...screwing the two screws on the plate located in front of the motor Grease can then be applied into the gear box using a grease tube dispenser Use motor oil 1OW 40 or 10W 30 for lubrication Apply oil s...

Страница 27: ...of the locomotive downward so that you can see one of the drive axles on each motor Using a toothpick or length of wire carefully apply two drops of oil to the axles at all four bronze bearings Now tu...

Страница 28: ...all drop of oil at the axles of the pickup rollers Wipe away excess oil with a cotton swab The rolling surface should be free from oil LUBRICATING THE TENDER Every 5 Hours 1 Add a single drop of motor...

Страница 29: ...intensity depending on the transformer voltage setting The headlight can be easily removed from its lampholder should the bulb expire To remove the bulb unclasp the boiler front clasp Pull the boiler...

Страница 30: ...is depressed fully the ProtoSound circuit may not recognize the signal Try pressing the whistle button slower taking approximately 1 second to fully depress the button BELL PROBLEMS REMEDY When I pre...

Страница 31: ...after the short whistle blast sounds You are waiting too long to turn the throttle back on after the short whistle blast sounds The power must be turned back on immediately after the short whistle bla...

Страница 32: ...ompleted This will guarantee that the system check will have been completed since the startup sounds take longer than 2 2 seconds to play If the problem persists we recommend that you operate the thro...

Страница 33: ...bell when the system enters Event 5 After approximately 15 rings of the bell it automatically will turn off Whenever PFA is enabled pressing the whistle and bell buttons has no affect Because PFA mus...

Страница 34: ...Lionel 1032 U A 5 16v 90 Watt Standard Lionel 1032M U A 5 16v 90 Watt Standard Lionel 1033 U A 5 16v 90 Watt Standard Lionel 1043 U A 5 16v 90 Watt Standard Lionel 1043M U A 5 16v 90 Watt Standard Li...

Страница 35: ...nded for children under ten years of age without adult supervision MTH recommends parents examine the toy transformer used to power this device periodically for conditions that may result in the risk...

Страница 36: ...ng elements AI 0000018 2 00 39 Motor smoke unit BE 0000041 5 00 40 Fan impellor smoke unit AI 0000019 2 00 41 Screw IA 0000120 0 15 42 Screw IA 0000027 0 15 43 Wire Harness PCB Plug BB 1040001 8 00 Mo...

Страница 37: ...37 260E Steam Engine Contemporary...

Страница 38: ...38 260E Steam Engine Contemporary...

Страница 39: ...39 260E Steam Engine Contemporary...

Страница 40: ...sales receipt and a full description of the problem must be included to facilitate the repairs Please include the description regardless of whether you discussed the problem with one of our service t...

Отзывы: