background image

TROUBLESHOOTING 

A.) PUMP WILL NOT RUN 

1.) Circuit breaker is open 

2.) Thermal overload has tripped 

3.) Improper voltage supplied to the 

motor 

4.) Wiring connections are loose 

5.) Blown fuse 

6.) Pump controls in off position 

7.) Motor wired improperly 

8.) Motor is defective 

B.) GPM CAPACITY IS LOW 

1.) Pump is not throttled correctly 

2.) Pump is running backwards 

3.) Pump has lost its prime 

4.) The impeller was sized wrong -the 

diameter is too small 

5.) Impeller is worn -clearance 

opened up 

6.) Air or gas in the liquid

7.) NPSHA is to low 

8.) Piping is undersized 

9.) The impeller has a vane or vanes 

plugged with debris 

10.) A strainer is partially plugged 

11.) Pump is undersized for the 

system 

12.) Phase loss -one leg of a 3-phase 

motor went out 

C.) EXCESSIVE NOISE/VIBRATION 

1.) Rotating parts are binding 

2.) Pump is cavitating 

3.) Defective motor 

4.) Pump is running backwards 

5.) Air or gas in system 

6.) Impeller is plugged with debris 

7.) Pump or piping is loose 

8.) Pump is not throttled correctly 

- running wide open 