Safety
o
The machine is intended for professional use by tattoo artists only. The manufacturer is not responsible for the
improper use of equipment and its parts! And also for non-compliance with the standards of sterilization and
disinfection.
o
Disposable cartridges must be used. Wipe down the machine with a disinfectant before and after use.
o
Be sure to use a barrier protective
o
Always use disposable gloves during the session.
Work
Before use:
o
Unscrew the cover counterclockwise, insert the 18650 battery with the negative * contact towards you,
tighten the cover as far as it will go.
*The negative contact is a flat, completely flat edge of the battery without a protective film.
o
Press the “MT” button to turn it on and for a few seconds listen to how it works.
o
The sound should be smooth, without extraneous clicks and drops.
o
Turn off the machine by short pressing the “MT” button.
o
Insert the cartridge and adjust the stroke of the needle by rotating the holder. The machine is ready to
go.
Magnetic stand with pause function:
When you put the machine on the stand, it detects this automatically and goes into standby mode, turning off the
engine. When you pick up the machine again, it will start the engine with the settings set before the standby was on. It is
most convenient to put and take the machine with the stand facing you, not away from you. Works automatically and does
not require power.
PLEASE NOTE: The stand is designed to be installed on a steel surface. Otherwise, due to the magnetic force
between the stand and the machine, they will "stick" to each other and it will be inconvenient to use it. Do not place the
machine on a stand with the plug facing down. In this position, the pause function may not work properly.
Also it may happen, that the engine simply does not have enough power to start after waiting, with a large needle
stickout and a rigid cartridge membrane in combination with a low operating voltage. In this situation, the electronics of
the machine will recognize this fact itself and supply the current necessary for starting, after will smoothly return to the
value set by the user. This procedure takes about 2 seconds.
Machine operation:
o
Switching on
–
Pressing the "
МТ
" button of any duration.
o
Switching off
- Short press of the
“MT” button.
.
o
Changing the display mode
- Holding the "MT" button
o
Exact voltage change in 0.1 V increments - Short press of the "+" or "-" button.
o
Rapid change of voltage in steps of 0.5 V - Hold down the "+" or "-" button.
o
Switching the voltage memory cell
- Simultaneous holding of the "+" and "-" buttons.
You can change the voltage from any display mode of the machine. It will automatically switch to the voltage
indication mode, and after a few seconds after adjustment, it will return to the previously set indication mode.
When turned off, the machine automatically writes into the memory the display indication mode, the number of
the memory cell and the voltage set in this cell. When resuming operation, it smoothly switches to the last set settings. The
memory of the machine is non-volatile and is retained when changing the battery.
Machine display modes:
-U-
In this mode, the machine shows the current operating voltage.
-P-
Display mode of the current battery charge in 5% increments.