Camera
Image sensor
CMOS
Resolution
640 x 480
Video system
PAL/NTSC
Viewing angle
36°
Transmission frequency
2468 MHz
Minimum illumination
0 Lux (LED ON)
Modulation type
FM
Bandwidth
18 MHz
Effective range
10 m
Flexible hose / lens
Ø 9 mm
IP protection class
Waterproof IP67 (only for lens and tube)
Power supply
4x AA batteries (1.5 V)
Operating temperature
10° ~ 50°
Operating humidity
max. 15 ~ 85% RH
Dimensions (H/W/D)
260 x 108 x 71 (without flexible hose)
Weight
ca. 476 g
Monitor
Screen
3.5“ TFT LCD
Resolution
320 x 240
Video system
PAL/NTSC
Transmission frequency
2468 MHz
Capacity of the SD card
2 GB – 32 GB
Supply voltage
9 V DC
Power consumption
max. 500 mA
Operating time
about 2 hours
Charging time
about 2,5 hours
Image type
JPEG
Video Type
MP4
Digital Zoom
yes
Frame rate
30 fps
Receiver sensitivity
≤-85dBm
Dimensions (W/H/D)
106 x 89 x 37 mm
Weight
232 g
Problem Likely
Possible Causes
Solutions
Tool will not start
1. Monitor not charged.
2. Batteries need charging.
1. charge monitor
2. replace batteries in control
handle
3. press the reset button to start
Monitor will not charge
1. Adapter cable not attached
properly
2. Adapter not connected to
power
1. make sure adapter cable is
connected between monitor
and adapter.
2. make sure adapter is securely
plugged into wall socket.
Image too dark or light
1. LEDs near camera need
adjustment
2. Monitor display needs adjust-
ment
1. use dial on control handle to
adjust brightness of LEDs.
2. use contrast and brightness
buttons on monitor to adjust
image.
NOTE: Follow all safety precautions whenever diagnosing or servicing the tool.
Disconnect power supply before service.
Declaration of Conformity
This attesting conformity with the following directives / standards:
Electromagnetic Compatibility Directive 2004/108 / EC
EN 55013: 2001 + A1: 2003 + A2: 2006
EN 55020: 2007
EN 61000-3-2:2006 + A1:2009 + A2:2009
EN 61000-3-3:2008
Low Voltage Directive 2006/95/EG
EN 60065: 2002 + A1: 2006 + A11: 2008
5. Specification
6. Troubleshooting
14
ENGLISH
15
ENGLISH