User’s Manual
SP112C Series
3. Battery Charge Current:
A. Solar Panel: depends on the solar panel, 10A max,
B. POE: fixed current, 2.0A max
4. Battery Types: 12V AGM Battery
5. Protection:
5.1
Battery Polarity Reverse Protection:
If only battery connected to terminal, when the battery polarities
were reversed, the model will stop output and REV indicator light
on. When the battery be removed and re-connected to terminal,
the function will be disable, if there is a PoE power sources be
connected, when the battery polarities reversed, the battery will be
disconnected.
5.2
Battery Over Discharge Protection:
Cuts off the load when the battery voltage is lower than 11V + 0.3V,
and auto recover when the battery voltage returns to 12 V + 0.3V
5.3
Battery Over Charge Protection:
Fuse control, over 15A, the fuse will be burnt.
5.4
Solar Panel Polarity Reverse Protection:
When solar panel polarities be reversed, the charger stop output, it
won’t damage the charger or end device
5.5
Solar Panel Over Charge Protection:
When charge current over 15A, the fuse will be burnt.