MSTRONIC SOL10P12 Series Скачать руководство пользователя страница 8

User’s Manual

                                                                                       

SOL10P12 Series 

 

5.6

 

Output Short Circuit Protection:  
When the rear output terminal or PoE output be short circuit, 
protection be active, the product stop output and auto-recover 
when the terminal back to normal connection. 

 

5.7

 

Battery Output Current Limit:  
The fuse will be burnt when battery output current over 10A 

  

5.8

 

Load Output Voltage Limit: 
The output voltage of the rear terminal is the same as battery. 

5.91   

POE Charge Voltage : 

 

Float = 13.4V ± 0.2V 
Equalize = 14.2V ± 0.2V 

5.92   

SOLAR Charge Voltage : 

Charge Voltage = 14.4 V ± 0.2V

 

 

 

6.

 

GENERAL DESCRIPTION 

6.1   Operation Temperature:         -40  -  +60 Degree 
6.2   Storage Temperature:             -40  -  +85 Degree 
6.3   Operation Humidity:                    5%  -  90% non-condensing 
6.4   Cooling:                                

Free air cooling  

6.5   SIZE                                        150*118*40mm (L*W*H)  

Содержание SOL10P12 Series

Страница 1: ...Mstronic Co Ltd SOL10P12 Series Solar PoE Battery Charger USER S MANUAL...

Страница 2: ...L10P12 56A1N SOL10P12 56B1N DIN Rail Mountable Support Gigabit Ethernet Applications Remote Power Systems Surveillance Sensors Wireless Station AP Client Repeaters UPS Systems Lighting Fences Gates Pr...

Страница 3: ...polarity reverse indicator the LED lights when the battery polarities are reversed detail description see Sec 5 1 6 IN PoE Input Jack the lower RJ45 jack used for PoE input Allowed input voltage 36 57...

Страница 4: ...3 The solar panel cannot be used stand alone without battery connected 4 When a solar panel and PoE input are connected to the charger if the voltage of solar panel is higher than 15V then solar pane...

Страница 5: ...SOL10P12 Series 8 It can be two separate outputs on the rear panel make sure the total draw is not over the limit 9 The V of PoE input Solar input and battery are not the same grounding must be prope...

Страница 6: ...erminal Output 2 at front upper RJ45 SOL10P12 24BNN 12V 10A as Bat Volt 24V 1 25A 45 78 regulated SOL10P12 48ANN 12V 10A as Bat Volt 48V 0 625A 12 36 regulated SOL10P12 48ANR 12V 10A as Bat Volt 48V 0...

Страница 7: ...function will be disable if there is PoE power sources connected when the battery polarities reversed the fuse will be burnt 5 2 Battery Over Discharge Protection Cuts off the load when the battery vo...

Страница 8: ...The fuse will be burnt when battery output current over 10A 5 8 Load Output Voltage Limit The output voltage of the rear terminal is the same as battery 5 91 POE Charge Voltage Float 13 4V 0 2V Equal...

Страница 9: ...3 Vdc BI_DB power Data Pair B Vdc BI_DB power Data Pair B 4 Vdc BI_DC power Data Pair C Vdc BI_DC power Data Pair C 5 Vdc BI_DC power Data Pair C Vdc BI_DC power Data Pair C 6 Vdc BI_DB power Data Pai...