background image

User’s  Manual

                                                                               

                PSE-SW3B44DB 

 
 

 
MSTRONIC CO., LTD.                                                         

                                                                   

   

 

12

 

 

  PSE disconnect mode      DC disconnect 

 

  PoE auto detection 

IEEE802.3af , IEEE802.3at (2 event classification) & 

IEEE802.3bt(multi-event classification) 

 

  PoE protection 

 

  Over-temperature, over-current, over/under voltage 

 

LEDs                                *Link/Activity (Green ON/ Green Blinking @1000Mbps,       

Yellow/Yellow Blinking @10M/100Mbps)           

                                            *PoE (Yellow)    port 1-2 ON - PD detect, deliver power via 4 data ports 

                                                                              Blinking-PD detect, deliver power via 2 data ports 

                                                                        Port UPLINK ON –power via PoE PSE 

 

 

                            *POWER            Green-normal 

 

  Power input                      Port UP LINK from network switch or midspan, or option DC power 

supply 

 

  Power consumption        less than 5W when without PD loading 

 

  Operating temperature     

-20

~+70

℃ 

 

 

  Operation humidity          90% relative humidity, non-condensing 

 

  Storage temperature       

-40

~+85

℃ 

 

  Dimension                      40mm(H)x116mm(W)x90mm(D)    available for DIN RAIL Mounted 

   

 

Содержание PSE-SW3B44DB

Страница 1: ...USER S MANUAL MSTRONIC CO LTD PSE SW3B44DB 3 Port PoE Switch Extender Repeat Ethernet and PoE ...

Страница 2: ...anual PSE SW3B44DB MSTRONIC CO LTD 2 1 General Information 2 Hardware Description LED Indicators Power Wiring Ethernet Port Wiring PD Port Wiring Network Application 3 Technical Specification 3 3 3 5 7 9 10 11 ...

Страница 3: ...at and IEEE802 3bt standard to receiver and deliver both of Ethernet data and DC power through the traditional UTP or STP cable The PoE Switch can extend Ethernet data and DC power up to 200 meters This manual will help you install and maintain the PoE switch Installation of the PoE switch is very easy and you will begin to operate as soon as you are powered up 2 Hardware Description LED Indicator...

Страница 4: ...ndicator on RJ45 LED STATUS Description P1 P2 UP LINK Link Act Green A network device is detected 1000Mbps but no communication activity is detected Green Blinking This port is transmitting to or receiving package from another device at 1000Mbps Yellow A network device is detected 10Mbps or 100Mbps but no communication activity is detected Yellow Blinking This port is transmitting to or receiving ...

Страница 5: ...for 2X802 3at PoE ports or 185W for 4X 802 3bt PoE ports The input voltage must in the range of 44V to 57VDC if using for 802 3af operation The input voltage must in the range of 50V to 57VDC if using for 802 3at 802 3bt type 3 operation The input voltage must in the range of 53V to 57VDC if using for 802 3bt type 4 operation The PoE switch PSE SW3B44D4 allow powered by another PoE source on UPLIN...

Страница 6: ...K may get DC power over the Ethernet cable the connection as Data pair A plus V V on line 1 and 2 Data pair B plus V V on line 3 and 6 Data pair C plus V V on line 4 and 5 Data pair D plus V V on line 7 and 8 The terminal block on rear panel should be wiring as ...

Страница 7: ... regard to using straight through or crossover cabling Port 1 Port 2 provides Power over Ethernet function that delivers DC power through the data pairs 4 pairs or 2 pairs to the PD UPLINK port provides Power Device function that receive power from 4 pairs or 2 pairs Ethernet cable The following tables describe the wiring diagram of straight through and crossover cabling That crossover cables simp...

Страница 8: ...ct the other side to your attached device The Link Act LED green or yellow will light up when the cable is correctly connected Refer to the LED Indicator section for descriptions of each LED indicator If a port LED is off go back and check for connectivity problems between that port and the network device connected The maximum cable length for 10 100 1000BaseT with Cat 5 twisted pair cables is typ...

Страница 9: ... B All 1 Negative Vport Positive Vport 2 Negative Vport Positive Vport 3 Positive Vport Negative port 4 Positive Vport 5 Positive Vport 6 Positive Vport NegativenVport 7 Negative Vport 8 Negative Vport Be sure the twisted pair cable is bound with the standard RJ 45 pin If the RJ 45 is bound with the wrong pin number PoE switch will not recognize the PD and won t deliver DC power to PD The yellow P...

Страница 10: ...r from PoE midspan and provide power to the PD which follows the IEEE 802 3af at standard in the network The PoE Switch can be installed in a more appropriate position for better performance to extend Ethernet to 200 meters The following figure is an example of a network application for PoE Switch ...

Страница 11: ...nd forward Protocols CSMA CD Flow control IEEE802 3x full duplex back pressure half duplex Data transmission rate 1488000pps for1000base T 148800pps for 100base T 14880pps for 10base T Address table 1K MAC address table self learning Connect RJ 45 PoE port Port 1 2 PSE auto power management A B mode data pair A plusV 1 2 data pair B plusV 3 6 data pair C plusV 4 5 data pair D plus V 7 8 Port UPLIN...

Страница 12: ...ow Yellow Blinking 10M 100Mbps PoE Yellow port 1 2 ON PD detect deliver power via 4 data ports Blinking PD detect deliver power via 2 data ports Port UPLINK ON power via PoE PSE POWER Green normal Power input Port UP LINK from network switch or midspan or option DC power supply Power consumption less than 5W when without PD loading Operating temperature 20 70 Operation humidity 90 relative humidit...

Отзывы: