background image

17

Celsius/Fahrenheit Toggle Button: 

The temperature can be displayed in either Celsius  

or Fahrenheit.  The system's default is Celsius.

Ozonator Button: 

Activate the Ozone. The Ozone icon shows when the Ozone function is 

activated. For bathers' safety concern, the ozonator cannot be operated at the same time 

when the Bubbling function is on. The Ozonator will be off automatically after opearting for 2 

hours. Ozone output is 50-80mg/Hr.

NOTE: Please do not soak in the spa when the Ozone is on. The Ozonator will not work 

when the spa has no water or when the Bubble Button is on.

IMPORTANT

The following conditions will lead to slow water heating 

●   The ambient temperature is lower than 10°C(50°F)

●   Outdoor wind speed is above 3.5-5.4m/s(8-12mph)

●   The air bubble function is activated when heater is on

●   The spa is not properly covered with the spa cover when heater is on

ERROR CODE CHART

LCD READING

CAUSE

SOLUTION

Water temperature is lower than zero 
degree or exceed 55°C(131°F)
Temperature sensor failure
Water pressure switch failure
Filter failure
Water level is not at the minimum water line
Detecting function failure 
No water in the spa tub

Contact the MSpa Service Center.

Contact the MSpa Service Center.

Add more water to the minimum line.

Add more water to the minimum line.
System self-checking

Step 1: Fill water to the water line, and make 

            sure that there is no bather or 

            object in the spa tub.

Step 2: Connect the power supply, press 

            RESET button on the PRCD.

Step 3: If E3 shows, contact the MSpa 

            Service Center. If E3 is flashing, 

            press ON/OFF, C/F,TEMP+ buttons 

            once insequence, enter to the 

            self-checking system. If no error 

            code shows, failure is not detected. 

            It is OK to use the spa. If error code 

            shows after self-checking, contact 

            the MSpa Service Center.

Contact the MSpa Service Center.

Change the water or contact the MSpa 
Service Center.

Heating failure

System failure

E3

E4

E0

E1

E2

Содержание PM-610S Tuscany

Страница 1: ...CT MSPA AT info the mspa com Due to MSpa continuous product improvement MSpa reserves the right to change specifications and product appearance which may result in updates to the instruction manual wi...

Страница 2: ...21 22 23 24 25 Thank you for choosing MSpa and for your confidence in our brand We believe that you will enjoy many benefits of using MSpa products for years to come To guide you in your initial MSpa...

Страница 3: ...damaged it must be replaced by the manu facturer its service agent or similarly qualified persons in order to avoid a hazard Risk of Electric Shock Do not permit any electrical appliances such as a li...

Страница 4: ...d from the spec sheet calculate the expected load of water capacity plus total weight Adequate draining system must be provided around the spa to deal with over flow water To reduce the risk of injury...

Страница 5: ...or hot tub Water temperature in excess of 42 C 108 F may be injurious to your health Never use a spa or hot tub alone or allow others to use the spa alone Do not use a spa or hot tub immediately foll...

Страница 6: ...not operating Always enter and exit the spa or hot tub slowly and cautiously Caution of wet floor To avoid damage to the pump never turn on the spa or hot tubs unless it is filled with water to the mi...

Страница 7: ...ixed partitions Zones Zone 0 Zone 1 Zone 2 Description of the zones Zone 0 is the interion of the basin including any recesses in their walls or floors Zone 1 is limited by Zone 0 A vertical plane 2m...

Страница 8: ...ht PM 610S Tuscany Octagon Octagon 860 Ltr 227 gal 1200 Ltr 317 gal 1 62m 64 1 93m 76 0 68m 27 0 73m 29 59 5kg 131 2lbs 71 5kg 157 6lbs PM 610S 710S 220 240V 50Hz 2300W 1500W 3 Levels Level 1 300W Lev...

Страница 9: ...9 PRODUCT OVERVIEW Packaging content NOTE Drawings for illustration purpose only Actual product may vary Not to scale A B C D E F G H I J K N O P Q L M L M...

Страница 10: ...ctor or structural engineer to verify the requirement Make sure the floor is water resistant and provides non slip surface Do not install the spa on a carpet of any other material that could damaged b...

Страница 11: ...PRCD The PRCD indicator should shut off If the PRCD indicator does not turn off the PRCD is faulty Do not use the spa Contact a qualified electrician to correct the fault Press the RESET button on th...

Страница 12: ...assembly 4 1 First find the Open end panel and place it to where you wish to locate your control box Install the Slide Corner Beams onto each side of the Open end panel Note Make sure the Corner Beam...

Страница 13: ...pipe to the PVC transparent pipe protruding from the Liner firstly and then fixed with nylon tie belt Figure 6 1 6 2 Connect the control box fittings to the pipes protruding from the Liner Ensure the...

Страница 14: ...he control panel Close and recess the inflation valve a 8 3 Place the inflated air bladder and the top lid cover over the spa tub and make sure the spa cover are closed with buckles and lock the buckl...

Страница 15: ...2 C 1 8 C 2 F 3 F for PM 610S and 0 5 C 1 5 C 1 5 F 2 F for PM 710S 8 3 9 Buckle Operation Lock the Buckle Insert the spa cover buckle into the buckle on the corner beam until you hear a Click sound...

Страница 16: ...TE Auto filtration system every 4 hours Heater Button Use this button to activate the HEATING and FILTRATION function at the same time The heater will heat the spa water until the water temperature re...

Страница 17: ...r when heater is on ERROR CODE CHART LCD READING CAUSE SOLUTION Water temperature is lower than zero degree or exceed 55 C 131 F Temperature sensor failure Water pressure switch failure Filter failure...

Страница 18: ...ean and sanitized Always practice good hygiene To ensure proper spa water quality by following these procedures 1 Inspect and clean the filter cartridge after each use and change the filter cartridge...

Страница 19: ...n on the bubble air blower and help to dissolve the chemicals into the water Never mix chemicals together Add the chemicals to the spa water separately Thoroughly dissolve each chemical before adding...

Страница 20: ...stem Operate the bubbling function for 15 minutes to blow out all the remaining water Fig 5 7 When the water stops draining use a clean towel to wipe up any remaining water and moisture on the spa tub...

Страница 21: ...Use 1 Drain and clean the spa by following the Drainage and Spa Cleaning sections 2 Reserve the set up instructions to deflate and disassemble the spa tub spa control unit and air bladder 3 Make sure...

Страница 22: ...a liner Drainage valve is not closed completely Tighten the inlet and outlet connection Repair the leaking hole spilt with the repair kit material Contact the MSpa Service Center PROBLEM CAUSE SOLUTIO...

Страница 23: ...urpose fire lightening flood or other external causes This warranty is valid only in the country of purchase in such countries where MSpa sells and services the same model with identical technical spe...

Страница 24: ......

Отзывы: