background image

3-16

BIOS Setup

MS-S0361

BIOS Setup

MS-S0361

Boot

Bootup NumLock State

Ths settng s to set the Num Lock status when the system s powered on. Settng to 

[On] wll turn on the Num Lock key when the system s powered on. Settng to [Off] wll 

allow users to use the arrow keys on the numerc keypad.

Quiet Boot

Ths BIOS feature determnes f the BIOS should hde the normal POST messages wth 

the motherboard or system manufacturer’s full-screen logo.
When t s enabled, the BIOS wll dsplay the full-screen logo durng the boot-up se-

quence, hdng normal POST messages.
When t s dsabled, the BIOS wll dsplay the normal POST messages, nstead of the 

full-screen logo.
Please note that enablng ths BIOS feature often adds 2-3 seconds of delay to the 

booting sequence. This delay ensures that the logo is displayed for a sufficient amount 

of tme. Therefore, t s recommended that you dsable ths BIOS feature for a faster 

boot-up tme.

CSM16 Module Version

Ths tem show the CSM16 module verson.

Option ROM Messages

Ths tem s used to determne the dsplay mode when an optonal ROM s ntalzed 

durng POST. When set to [Force BIOS], the dsplay mode used by AMI BIOS s used. 

Select [Keep Current] f you want to use the dsplay mode of optonal ROM.

Содержание MS-S0361

Страница 1: ...MS S0361 v1 X Server Board...

Страница 2: ...s registered trademarks of Microsoft Corporation AMI is registered trademark of Advanced Micro Devices Inc Award is a registered trademark of Phoenix Technologies Ltd Sound Blaster is registered trade...

Страница 3: ...inserting any add on card or mod ule All cautions and warnings on the equipment should be noted Never pour any liquid into the opening that could damage or cause electrical shock If any of the follow...

Страница 4: ...unsorted household waste Please use the public collection system to return recycle or treat them in compliance with the local regulations Taiwan For better environmental protection waste batteries sh...

Страница 5: ...elevision recep tion which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the measures listed below Reorient or reloc...

Страница 6: ...mehr als kommunale Abf lle entsorgt werden MSI hat europaweit verschiedene Sammel und Recyclingunternehmen beauftragt die in die Europ ische Union in Verkehr gebrachten Produkte am Ende seines Lebensz...

Страница 7: ...r de producten die de merknaam MSI dragen en verkocht zijn in de EU Deze goederen kunnen geretourneerd worden op lokale inzamelingspunten SRPSKI Da bi za titili prirodnu sredinu i kao preduze e koje v...

Страница 8: ...h sb rn ch MAGYAR Annak rdek ben hogy k rnyezet nket megv dj k illetve k rnyezetv d k nt fell pve az MSI eml kezteti nt hogy Az Eur pai Uni EU 2005 augusztus 13 n hat lyba l p az elektromos s elektron...

Страница 9: ...io Frequency Interference Statement v WEEE Statement vi Chapter 1 Overview 1 1 Mainboard Specifications 1 2 Mainboard Layout 1 4 Watch Dog Timer Setting 1 6 Chapter 2Hardware Setup 2 1 Quick Component...

Страница 10: ......

Страница 11: ...the MS S0361 accommodates the Intel Cedaview processor CPU GPU Northbridge and supports up to 2 SO DIMM slots to provide the maxi mum of 4GB memory capacity In the entry level and mid range market se...

Страница 12: ...e Intel NM10 Express chipset Memory 2 DDR3 1066 800MHz SO DIMM slots Supports the maximum of 4GB Unbuffered non ECC DIMM LAN Supports Gigabit LAN by Intel 82583V Gb Ethernet controller Supports Ethern...

Страница 13: ...CPLD pinheader 1 GPIO pinheader 1 LAN1 2 bypass status pinheader 1 Keyboard mouse connector 1 LPC pinheader for debugging Slot 1 PCIE x1 edge type slot optional Form Factor Mini ITX 170mm x 170mm Mou...

Страница 14: ...1 4 Overview Overview Mainboard Layout MS S0361 v1 X Mainboard ATX Power...

Страница 15: ...MS S0361 1 5 MS S0361 MS S0361 v1 X Mainboard DC Power...

Страница 16: ...ct Logical Device 8 mov dx 04eh mov al 07h out dx al point to Logical Device Number Register inc dx mov al 08h select Logical Device 8 out dx al C Enable watchdog timer Activate WDTO mov dx 04eh CR 30...

Страница 17: ...MS S0361 1 7 MS S0361 mov dx 04eh CR F7h bit 4 fill 0 clear event mov al 0f7h out dx al inc dx in al dx and al 0efh out dx al CR F6h bit0 7 fill in counter time...

Страница 18: ...1 8 Overview D Exit configuration mode mov dx 04eh mov al 0aah out dx al...

Страница 19: ...ion be careful in holding the components and follow the installation procedures For some components if you install in the wrong orientation the components will not work properly Use a grounded wrist s...

Страница 20: ...1 p 2 14 COM3 p 2 13 Rear Panel I O p 2 7 JCI1 p 2 12 DIMM Slots p 2 4 SYSFAN1 p 2 11 JHDDPWR1 p 2 6 CPU_F1 p 2 11 JFP1 p 2 12 JP8 p 2 15 JBAT1 p 2 16 JUSB1 2 p 2 13 SATA0 1 p 2 11 ATX1 p 2 5 JP4 p 2...

Страница 21: ...2 14 JSPI1 p 2 14 COM3 p 2 13 Rear Panel I O p 2 7 JCI1 p 2 12 DIMM Slots p 2 4 SYSFAN1 p 2 11 JHDDPWR1 p 2 6 CPU_F1 p 2 11 JFP1 p 2 12 JP8 p 2 15 JBAT1 p 2 16 JUSB1 2 p 2 13 SATA0 1 p 2 11 JPWR1 p 2...

Страница 22: ...n the memory module is deeply inserted in the DIMM slot Then push it down The slot clip at each side of the DIMM slot will automatically close when the memory module is properly seated Manually check...

Страница 23: ...in ATX power supply please plug your power supply along with pin 1 pin 13 1 3 3 3 V 1 3 3 V 1 4 1 2 V 2 3 3 V 1 5 G r o u n d 3 G r o u n d 1 6 P S O N 4 5 V 1 7 G r o u n d 5 G r o u n d 1 8 G r o u...

Страница 24: ...are Setup DC Adapter Connector JPWR1 for DC model This connector is used to connect DC power adapter HDD Power Connector JHDDPWR1 This connector provides power to the hard disk drives 4 1 PIN SIGNAL 1...

Страница 25: ...MS S0361 2 7 MS S0361 Rear Panel I O LAN LAN Bypass Enable LAN Bypass Disable LAN LAN LAN WAN JLAN1 USB ports RJ45 serial console port JLAN3 JLAN2 JLAN4 WAN WAN WAN...

Страница 26: ...d RJ 45 LAN jack is for connection to the Local Area Network LAN You can connect a network cable to it LED Color LED State Condition Left Yellow Off LAN link is not established On steady LAN link is e...

Страница 27: ...GPIO25 26 28 CFG 3 1 to control LAN 1 2 behavior Bypass PassThrough WDT 2 set GPIO29 CPLD_SendBIT high about 150ms then set it low about 100ms to complete the LAN pair configuration progress 3 go to...

Страница 28: ...2 10 Hardware Setup Hardware Setup Boolean table for CPLD behavior of Bypass PassThrough WDT function LAN1 2...

Страница 29: ...with 12V When connecting the wire to the connectors always note that the red wire is the positive and should be connected to the 12V the black wire is Ground and should be connected to GND If the mai...

Страница 30: ...ty and clear the record 2 INTRUER_N GND 1 Front Panel Connectors JFP1 This connector is provided for electrical connection to the front panel switches and LEDs and is compliant with Intel Front Panel...

Страница 31: ...ry Detect Serial In or Receive Data Serial Out or Transmit Data Data Terminal Ready Ground Data Set Ready Request To Send Clear To Send Ring Indicate 9 10 1 2 Front USB Connector JUSB1 JUSB2 This conn...

Страница 32: ...TPM Connector JTPM1 This connector connects to an optional TPM Trusted Platform Module Please refer to the TPM security platform manual for more details PIN SIGNAL DESCRIPTION PIN SIGNAL DESCRIPTION 1...

Страница 33: ...SIGNAL PIN SIGNAL 1 3 5 SIO_GP70_User1 SIO_GP73_User3 SIO_GP75_User5 2 4 6 SIO_GP72_User2 SIO_GP74_User4 SIO_GP76_User6 6 1 LAN1 LAN2 Bypass LED Connector JP3 This connector can connect the LED modul...

Страница 34: ...t You can clear CMOS by shorting 2 3 pin while the system is off Then return to 1 2 pin position Avoid clearing the CMOS while the system is on it will damage the main board Slots PCIE Peripheral Comp...

Страница 35: ...MS S0361...

Страница 36: ...ws you to configure the system for op timum use You may need to run the Setup program when An error message appears on the screen during the system booting up and requests you to run SETUP You want to...

Страница 37: ...te keys Important The items under each BIOS category described in this chapter are under continuous update for better system performance Therefore the description may be slightly different from the la...

Страница 38: ...er symbol as shown in the right view appears to the left of certain fields that means a sub menu can be launched from this field A sub menu contains additional options for a field parameter You can us...

Страница 39: ...tures Chipset This menu controls the advanced features of the onboard Host Bridge and South Bridge Boot Use this menu to specify the priority of boot devices Security Use this menu to set supervisor a...

Страница 40: ...e specifications of your system Read only Intel RC Version These items show the of the Intel RC version System Date This setting allows you to set the system date The date format is Day Month Date Yea...

Страница 41: ...Advanced Launch PXE OpROM Use this setting to launch the PXE option ROM RTC Wake Setting RTC Wake Settings When Enabled your can set the date and time at which the RTC real time clock alarm awakens th...

Страница 42: ...to protect against compromised networks CPU Configuration Hyper Threading The processor uses Hyper Threading technology to increase transaction rates and reduces end user response times The technolog...

Страница 43: ...application code can execute and where it cannot When a malicious worm attempts to insert code in the buffer the processor disables code execu tion preventing damage or worm propagation Configure SATA...

Страница 44: ...port Set to Enabled if you need to use any USB 1 1 2 0 device in the operating system that does not support or have any USB 1 1 2 0 driver installed such as DOS and SCO Unix Set to Disabled only if yo...

Страница 45: ...onfiguration Serial Port This setting enables disables the specified serial port Device Settings This setting is used to change the address IRQ settings of the specified serial port H W Monitor These...

Страница 46: ...the terminal screen Besides all data received from the serial port is interpreted as keystrokes from a local keyboard Console Redirection Settings Terminal Type To operate the system s console redirec...

Страница 47: ...ion resolution of legacy OS Serial Port for Out of Band Management Windows Emergency Man agement Services EMS Console Redirection operates in host systems that do not have a monitor and keyboard attac...

Страница 48: ...of data from one device to another to ensure that the receiving device can handle all of the incoming data This is particularly important where the sending device is ca pable of sending data much fas...

Страница 49: ...es whether your system will reboot after a power failure or inter rupt occurs Available settings are Power Off Leaves the computer in the power off state Power On Leaves the computer in the power on s...

Страница 50: ...er a hardware timer that generates either a LAN bypass or a system reboot when the software that it monitors does not respond as expected each time the watch dog polls it LAN1 LAN2 ByPass state Power...

Страница 51: ...uence hiding normal POST messages When it is disabled the BIOS will display the normal POST messages instead of the full screen logo Please note that enabling this BIOS feature often adds 2 3 seconds...

Страница 52: ...to set the sequence of boot devices where BIOS attempts to load the disk operating system First press Enter to enter the sub menu Then you may use the arrow keys to select the desired device then pre...

Страница 53: ...ers will be prompt ed for Administrator password only when they enter BIOS Setup User Password User Password controls access to the system at boot and access to the BIOS Setup util ity Users will be p...

Страница 54: ...changes to CMOS and reset the system Discard Changes and Reset Abandon all changes and reset the system Save Changes Save all changes and continue with the Setup Utility Discard Changes Abandon all ch...

Отзывы: