MSI MS-9298 Скачать руководство пользователя страница 46

3-10

Mainboard Setup

MS-9298

Mainboard Setup

MS-9298

r

ear

 p

anel

 i/o

    Serial Port
    D-sub VGA Port
    USB Port
    System ID LED
    System ID Switch
    NMI Switch
    Serial Console Port (for BMC)
    Gigabit LAN Jack
    PS/2 Mouse Port
    PS/2 Keyboard Port

1�
2�
3�
4�
5�
6�
7�
8�
9�
10�

 2

 3

 4

 1

 5

 7

 6

 8

 10

 9

Содержание MS-9298

Страница 1: ...MS 9298 2U Rackmount Server...

Страница 2: ...arks of Microsoft Corporation AMI is registered trademark of Advanced Micro Devices Inc Award is a registered trademark of Phoenix Technologies Ltd Sound Blaster is registered trademark of Creative Te...

Страница 3: ...nings on the equipment should be noted Never pour any liquid into the opening that could damage or cause electrical shock If any of the following situations arises get the equipment checked by ser vic...

Страница 4: ...Tma specified by the manufacturer Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised M...

Страница 5: ...dential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Notice 1 The changes or modifications not expressly approved...

Страница 6: ...ehr als kommunale Abf lle entsorgt werden MSI hat europaweit verschiedene Sammel und Recyclingunternehmen beauftragt die in die Europ ische Union in Verkehr gebrachten Produkte am Ende seines Leb ensz...

Страница 7: ...de producten die de merknaam MSI dragen en verkocht zijn in de EU Deze goederen kunnen geretourneerd wor den op lokale inzamelingspunten SRPSKI Da bi za titili prirodnu sredinu i kao preduze e koje vo...

Страница 8: ...h sb rn ch MAGYAR Annak rdek ben hogy k rnyezet nket megv dj k illetve k rnyezetv d k nt fel l pve az MSI eml kezteti nt hogy Az Eur pai Uni EU 2005 augusztus 13 n hat lyba l p az elektromos s elek tr...

Страница 9: ...iew 1 1 System Overview 1 2 System Specifications 1 7 Chapter 2 System Assembly 2 1 Getting Started 2 2 System Assembly 2 3 System Mounting 2 16 Chapter 3 Mainboard Setup 3 1 Quick Components Guide 3...

Страница 10: ......

Страница 11: ...optimal system efficiency the MS 9298 accommo dates the latest Intel Xeon 5500 Series processor and supports up to 12 DDR3 800 1066 1333 DIMM slots In the advanced level and mid range market segment t...

Страница 12: ...Top View NOTE Before removing the rear cover make sure that you remove the ODD front bezel first to avoid collision and damage HDD Bay Axial Fan Module redundant Fan Duct PCI Riser Card Bracket SSI EP...

Страница 13: ...rive Tape Module Tray Swappable Hard Disk Drive Bay System ID LED System Fault LED LAN LED Power LED HDD LED System ID Switch Power Switch NMI Switch Reset Switch USB Port D sub VGA Port 1 2 3 4 5 6 7...

Страница 14: ...No disk activity LAN1 LAN2 Activity Green On LAN link Green Blink LAN access activity System Fault Green On Running normal operation Amber On Critical or non recoverable condition Amber Blink Non cri...

Страница 15: ...m ID LED System ID Switch NMI Switch Serial Console Port for BMC Gigabit LAN Jack PS 2 Mouse Port PS 2 Keyboard Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 2 3 4 1 5 12 7 6 11 13 14 8 10 9 Important When PS...

Страница 16: ...Description LAN Linkage Green On LAN linked Green Blink LAN accessing Off Off No LAN linked LAN Speed Yellow On Gigabit mode Green On 100M mode Off Off 10M mode System ID Blue On Blink Identified as a...

Страница 17: ...wap SAS SATA HDDs supported by SAS SATA RAID card LAN Gigabit Fast Ethernet by Intel 82576EB System Management ServerEngines Pilot2 baseboard management controller IPMI 2 0 compliant Graphics ServerEn...

Страница 18: ...Dimension 483mm W x 711mm D x 88 mm H Externally swappable 3 5 inch SATA HDD bay x 6 3 5 inch tape bay x 1 Slim DVD bay x 1 FDD bay x 1 Full height slot x 2 Low profile slot x 3 Power Supply 750 Watt...

Страница 19: ...n be careful in holding the components and follow the installation procedures For some components if you install in the wrong orientation the components will not work properly Use a grounded wrist str...

Страница 20: ...the system on a flat and stable surface Do not place the system in environments subject to mist smoke vibration excessive dust salty or greasy air or other corrosive gases and fumes Do not drop or jol...

Страница 21: ...Assembly System Cover Step 1 Loosen the thumbscrew on the rear bezel of the system Step 2 Press the release buttons and slide the front chassis cover forwards Step 3 Lift the front chassis cover up to...

Страница 22: ...mbly Step 4 Press the release buttons and slide the rear chassis cover backwards to remove it from the chassis Important Before you remove or install any components make sure the system is not turned...

Страница 23: ...hance heat dissipation of the CPU To remove the fan duct first unscrew the metal bracket on its top Step 2 Locate the riser card bracket and lift it up from the chassis Step 3 Remove the metal bracket...

Страница 24: ...6 System Assembly System Assembly Step 5 Remove the dummy heat sink on the CPU2 socket Step 6 Locate the CPU1 socket Open the load lever and lift it up to its fullest extent Step 7 Open the load plat...

Страница 25: ...rom the lever hinge side Step 9 After confirming the CPU direction for correct mating put down the CPU in the socket housing frame Be sure to grasp on the edge of the CPU base Note that the alignment...

Страница 26: ...he load lever lightly onto the load plate and then secure the lever with the hook under the retention tab Step 12 Place the heat sink on top of CPU1 and secure the screws on both sides Step 13 Follow...

Страница 27: ...S 9298 2 9 MS 9298 Memory Step 1 Locate the DIMM1 slot Step 2 Flip the slot clips outwards Step 3 Align the notch on the DIMM with the key on the slot and insert the DIMM vertically into the DIMM slot...

Страница 28: ...he DIMM is properly seated Step 5 Replace the fan duct on top of the CPU and DIMM Important In Multi Channel mode make sure that you install memory modules of the same type and density in different ch...

Страница 29: ...l B0 CPU2_DIMM2 Channel B0 CPU1_DIMM5 Channel B1 CPU2_DIMM5 Channel B1 9 DIMMs CPU1_DIMM1 Channel A0 CPU2_DIMM1 Channel A0 CPU1_DIMM4 Channel A1 CPU2_DIMM4 Channel A1 CPU1_DIMM2 Channel B0 CPU2_DIMM2...

Страница 30: ...ser card bracket supports low profile and full length expansion cards Unscrew the cover plates and put them aside for later use Step 2 Insert your expansion card into an appropriate PCI E slot on the...

Страница 31: ...the metal bracket back and fasten it with screws Step 5 Align the riser card golden fingers with the PCI E slots on the mainboard Push the riser card bracket care fully downwards until its wedgelocks...

Страница 32: ...mbly System Assembly Hard Disk Drive Step 1 To release the hot swapping HDD tray flip open its lever and pull the tray out of the bay Step 2 Unscrew the HDD tray Step 3 Remove the tray and keep it asi...

Страница 33: ...MS 9298 2 15 MS 9298 Step 4 Fit the HDD into the tray with screw holes aligned Step 5 Fasten the HDD with screws Step 6 Insert the HDD set into the bay Step 7 Press the lever back in place...

Страница 34: ...d the system firmly to the rack and 2 lock the system halfway without directly sliding out of the rack when dismounting Step 1 The chassis rails and rack rails have been assembled together be forehand...

Страница 35: ...pull forward the locking tab and pull out the chassis rail The chassis rail should slide easily off the rack rail Step 4 Attach the chassis rail to the chassis with 3 screws Step 5 Follow the same pro...

Страница 36: ...o the rack with the cage nuts on the front and rear brackets Step 4 Follow the above procedures to install the second rack rail Step 5 Align the chassis rails with the rack rails Slide the sys tem int...

Страница 37: ...oard hardware configurations Incorrect setting of jumpers and connectors may damage your mainboard Please pay special attention not to connect these head ers in wrong direction DO NOT adjust any jumpe...

Страница 38: ...3 2 Mainboard Setup Mainboard Setup Quick Components Guide...

Страница 39: ...rial ATA II Connector SATA1 SATA2 3 11 Serial Attached SCSI Connector MINISAS1 3 11 IPMB Connector JIPMB1 3 12 Serial Port Connector COM1 3 12 Front USB Connector JUSB1 JUSB3 JUSB4 JUSB5 3 13 Jumper 3...

Страница 40: ...rom overheating Make sure that you apply an even layer of thermal paste or thermal tape between the CPU and the heatsink to enhance heat dissipation Replacing the CPU While replacing the CPU always tu...

Страница 41: ...tly Wrong installation will cause the damage of your CPU mainboard Open the load lever 1 Lift the load lever up and open the load plate 2 The CPU socket has a plastic cap on it to protect the contact...

Страница 42: ...the load lever lightly onto the load plate and then secure the lever with the hook under the reten tion tab 7 Important Read the CPU status in BIOS Whenever CPU is not installed always protect your CP...

Страница 43: ...IMM slots are intended for memory modules DDR3 240 pin 1 5V 48x2 96 pin 72x2 144 pin Memory Population Rules In Multi Channel mode make sure that you install memory modules of the same type and densit...

Страница 44: ...annel B0 CPU2_DIMM2 Channel B0 CPU1_DIMM5 Channel B1 CPU2_DIMM5 Channel B1 9 DIMMs CPU1_DIMM1 Channel A0 CPU2_DIMM1 Channel A0 CPU1_DIMM4 Channel A1 CPU2_DIMM4 Channel A1 CPU1_DIMM2 Channel B0 CPU2_DI...

Страница 45: ...the DIMM slot will automatically close when the memory module is properly seated Manually check if the memory module has been locked in place by the DIMM slot clips at the sides Important You can bare...

Страница 46: ...oard Setup Rear Panel I O Serial Port D sub VGA Port USB Port System ID LED System ID Switch NMI Switch Serial Console Port for BMC Gigabit LAN Jack PS 2 Mouse Port PS 2 Keyboard Port 1 2 3 4 5 6 7 8...

Страница 47: ...loss may occur during transmission Serial Attached SCSI Connector MINISAS1 The SAS connector is a new generation serial communication protocol for de vices designed to allow for much higher speed dat...

Страница 48: ...al port bracket PIN SIGNAL DESCRIPTION 1 2 3 4 5 6 7 8 9 10 DCD DSR RXD RTS TXD CTS DTR RI GND KEY Data Carry Detect Data Set Ready Serial In or Receive Data Request To Send Serial Out or Transmit Dat...

Страница 49: ...speed USB interface peripherals such as USB HDD digital cam eras MP3 players printers modems and the like PIN SIGNAL PIN SIGNAL 1 3 5 7 9 VCC USB0 USB0 GND KEY 2 4 6 8 10 VCC USB1 USB1 GND NC 1 2 9 10...

Страница 50: ...data Important You can clear CMOS by shorting 2 3 pin while the system is off Then return to 1 2 pin position Avoid clearing the CMOS while the system is on it will damage the mainboard BIOS Recovery...

Страница 51: ...word byshorting 2 3 pin while the system is off Then return to 1 2 pin position Avoid clearing the password while the system is on it will damage the mainboard RAID Select Jumper JRAID_SEL1 This jumpe...

Страница 52: ...E interface expansion cards Important When adding or removing expansion cards make sure that you unplug the power supply first Meanwhile read the documentation for the expansion card to config ure any...

Страница 53: ...ws you to configure the system for op timum use You may need to run the Setup program when An error message appears on the screen during the system booting up and requests you to run SETUP You want to...

Страница 54: ...s under each BIOS category described in this chapter are under continuous update for better system performance Therefore the description may be slightly different from the latest BIOS and should be he...

Страница 55: ...own in the right view appears to the left of certain fields that means a sub menu can be launched from this field A sub menu contains additional options for a field parameter You can use arrow keys to...

Страница 56: ...eatures Boot Use this menu to specify the priority of boot devices Security Use this menu to set supervisor and user passwords Chipset This menu controls the advanced features of the onboard Northbrid...

Страница 57: ...s show the firmware and hardware specifications of your system Read only System Time This setting allows you to set the system time The time format is Hour Min ute Second System Date This setting allo...

Страница 58: ...4 6 BIOS Setup BIOS Setup Advanced CPU Configuration...

Страница 59: ...nology treats the two cores inside the processor as two logical processors that can execute instruc tions simultaneously In this way the system performance is highly improved If you disable the functi...

Страница 60: ...election except Disabled determines the number of sectors trans ferred per block PIO Mode Indicates the type of PIO Programmed Input Output DMA Mode Indicates the type of Ultra DMA S M A R T This allo...

Страница 61: ...ion Hotplug USB FDD Support Set to Enabled if your need to use a hotplug USB interfaced FDD in the op erating system that does not support or have any USB driver installed such as DOS and SCO Unix USB...

Страница 62: ...trols the number of seconds the POST waits for the USB mass storage device after the start unit command is sent Emulation Type This setting enables you to set the type of device you want the USB mass...

Страница 63: ...s and faster interrupt handling Chipset ACPI Configuration High Performance Event Timer The High Precision Event Timer HPET was developed jointly by Intel and Microsoft to meet the timing requirements...

Страница 64: ...the SATA controller s AHCI Advanced Host Con troller Interface functionality It is a new interface specification that enables advanced SATA features like Native Command Queuing NCQ and hot plug ging A...

Страница 65: ...event log Mark All Events as Read Press Enter and a screen pops up asking users to confirm whether or not to clear all DMI event logs immediately Press Y and Enter the BIOS will clear all DMI event lo...

Страница 66: ...s show the status of the BMC Baseboard Management Control ler chip and its firmware version Read only View BMC System Event Log Use this function to view system event logs recorded by BMC Clear BMC Sy...

Страница 67: ...ss in BMC Current Subnet Mask in BMC Current Gateway in BMC Use these settings to view the IP address subnet mask and gateway in BMC Hardware Health Information These items display the current status...

Страница 68: ...etup Intel VT d Configuration Intel VT d Intel Virtualization Technology for Directed I O Intel VT d provides the ca pability to ensure improved isolation of I O resources for greater reliability secu...

Страница 69: ...data This is particularly important where the sending device is capable of sending data much faster than the receiving device can receive it Redirection After BIOS POST This setting determines whethe...

Страница 70: ...inappropriate access to confidential and sensitive information and to protect against compromised networks Execute TPM Command TPM commands are managed through a child node of the TPM Management cons...

Страница 71: ...ystem from suspend mode Resume By Ring An input signal on the serial Ring Indicator RI line in other words an incom ing call on the modem awakens the system from a soft off state Resume By PCI E Devic...

Страница 72: ...20 BIOS Setup BIOS Setup Boot Boot Settings Configuration Quick Boot Enabling this setting will cause the BIOS power on self test routine to skip some of its tests during bootup for faster system boo...

Страница 73: ...Wait For F1 If Error When this setting is set to Enabled and the boot sequence encounters an error it asks you to press F1 If disabled the system continues to boot without waiting for you to press any...

Страница 74: ...Change User Password User Password controls access to the system at boot These settings allow you to set or change the user password Chassis Intrusion The field enables or disables the feature of reco...

Страница 75: ...MS 9298 4 23 MS 9298 Chipset CPU Bridge Configuration QPI Links Speed QPI is an architecture which features high speed serial links for interconnec...

Страница 76: ...ion Onboard LAN1 LAN2 Boot The items enable or disable the initialization of the onboard LAN Boot ROMs during bootup Selecting Disabled will speed up the boot process Restore on AC Power Loss This set...

Страница 77: ...Setup Utility Discard Changes Abandon all changes and continue with the Setup Utility Load Optimal Defaults Use this menu to load the default values set by the mainboard manufacturer specifically for...

Отзывы: