Thank you for buying our product!

This unit is a precision optical instrument. Our product has been design to provide the highest level of

safety, however, improper operation or negligence in following the instructions in this manual may cause

personal injuries and property losses. In order to ensure your safety, prolong the life of this unit and

maintain it properly, please read this manual carefully before operating this unit.

Warning

Do not use or place the instrument in the place with high temperature, humidity or dust for a long

time

Suitable working temperature: 5

to 35

Suitable relative humidity 20% to 80% (25

)

Note: do not immerse the instrument in water or solvent

Note: do not place accessories not provided by our company in the frame body or other

t

ransmission

parts

Maintenance and storage

1. Wipe and clean all glass components with gauze. In order to remove fingerprints or other oil stains,

use a very small amount of 2 parts of ether + 1 part of ethanol mixture solution as cleaning agent, wet

the gauze and wipe it gently.

Ether and ethanol are extremely flammable and must be handled with care. Be careful not to put these

chemicals near open flames and possible sources of spark, such as switches. Be sure to use it in a well ventilated

room.

2. For the non optical parts of the device, do not use organic solvent to wipe, but clean cloth can be

used. If it is very dirty, please use a soft cloth with a small amount of neutral detergent to wipe.

3. Do not disassemble any part of the device arbitrarily, or it may cause failure or reduce performance.

Содержание MI-BGU-LED IX50

Страница 1: ...Guangzhou Micro shot Technology Co Ltd Inverted LED Fluorescence Attachment MI BGU LED IX50 IX70 User Manual Website www m shot com ...

Страница 2: ...Email sales mshot com ...

Страница 3: ...e do not place accessories not provided by our company in the frame body or other transmission parts Maintenance and storage 1 Wipe and clean all glass components with gauze In order to remove fingerprints or other oil stains use a very small amount of 2 parts of ether 1 part of ethanol mixture solution as cleaning agent wet the gauze and wipe it gently Ether and ethanol are extremely flammable an...

Страница 4: ...1 Content I Main parts 01 II Specification 02 Ⅲ Components 03 Ⅳ Installation 04 05 Ⅴ Note 05 ...

Страница 5: ...DM505nmLP EM510nmLP G excitation group EX530 40nm DM570nmLP EM590nmLP UV excitation group EX360 50nm DM400nmLP EM420nmLP Light source 3W LED cold light Observation Fluorescence bright field Transfer mode Pull push at three positions Blue green bright field Brightness adjustment Continuous adjustment Input power DC12V 2A Matched microscope Olympus IX50 IX70 ...

Страница 6: ...ass Power plug Connect AC adapter to supply power Brightness knob Used to adjust fluorescence lighting brightness Lever Move BGU filter groups and lamps Vents Heat transmission Fix slot Screw to fix the attachment body Light port Lever Power plug Fix slot Brigthness knob vents ...

Страница 7: ...enser please take it off Find the plastic box on right hand of the microscope as image 01 and take off it slightly Image 01 3 Insert in the illuminator from the right side of the microscope bottom body as image 02 and image 03 notice to match slider rail on the illuminator bottom with the microscope rail I Image 02 Image 03 ...

Страница 8: ...scence filter cube among blue green UV and bright field Image 05 Ⅴ Note 1 Push or pull lever to change fluorescence filter cube among blue green UV and bright field The O channel should be used in bright field 2 If no light is emitted from the illuminator check that the power adapter is properly connected 3 If the illuminator shakes check the locking screw on the right side of the microscope body ...

Отзывы: