MSH equipment BT UV-02-L Скачать руководство пользователя страница 1

Handleiding 

 
 

B TEC UV droger 2 en 4 lamps 

BT UV-02-L/BT UV-04-L

 

 
 
 
 
 
 

MSH equipment 

Appelmarkt 7 
1681 PE  Zwaagdijk-Oost 
Tel: 0228-561100 
Fax: 0228-561112 
Mail

[email protected]

 

 

 

Website:

 

www.msh-equipment.nl 

 

Taal: engels  

 

Содержание BT UV-02-L

Страница 1: ...eiding B TEC UV droger 2 en 4 lamps BT UV 02 L BT UV 04 L MSH equipment Appelmarkt 7 1681 PE Zwaagdijk Oost Tel 0228 561100 Fax 0228 561112 Mail info msh equipment nl Website www msh equipment nl Taal engels ...

Страница 2: ...dorf Ehlershausen Telephone 49 0 5085 97100 0 Fax 49 0 5085 97100 30 Email info btecsystems de www btecsystems de User Manual for Short Wave Ultra Violet Paint Curing Equipment equipment and facility engineering UV Emitter UV 02 L UV 04 L ...

Страница 3: ...rrent Rated Frequency Rated Power Input Protection Class Degree of Protection UV 02 L 230 V 10 A 50 Hz 2 x 400 W I IPX0 UV 04 L 230 V 10 A 50 Hz 4 x 400 W I IPX0 Tested according to EN 60335 1 A2 2006 EN 60335 2 30 A2 2007 EN 50366 A1 2006 This EC Attestation of Conformity is issued on a voluntary basis according to the Low Voltage Directive 2006 95 EC relating to electrical equipment designed for...

Страница 4: ...lations and Maintenance Advices 2 2 1 Work Area 2 2 2 Use 2 2 3 Electroshock Hazards 3 2 4 Fire and Explosion Hazards 4 2 5 UV Radiation Hazards 4 2 6 Maintenance and Care 5 2 7 Further Information 5 3 Technical Description of the Device 6 3 1 Technical Data 6 3 2 Wiring Diagram 7 3 3 Spare Parts List 8 4 Installation 9 5 Operation 11 6 Replacement of Emitter Lamp Tube 13 equipment and facility en...

Страница 5: ...you to read this document carefully before using the machine to reach maximum life and reliable operation Read this document carefully before commissioning and keep it for future reference The B TEC devices and machines are only allowed to be used for the purpose explicitly described below Any other use is in contrast with the regulations The manufacturer cannot be held liable for damages resultin...

Страница 6: ...please use the outdoor specific cables marked with W A or W for avoidance of electric shock Do not use this device in the immediate surroundings of a bath Keep the work area dry keep the working area clean and free of any obstructions oil waste article or other broken parts The machine should be well grounded for safety The grounding device should be connected to the proper output port under corre...

Страница 7: ...hen working Don t misuse the electric wire It is not allowed to drag the machine with the power wire or pull the power plug Please keep the power wire away from hot oily or sharp or movable objects Please replace damaged cables and wires immediately for avoidance of electric shocks 2 3 Electroshock Hazards Please read understand and follow the safety instructions below in order to reduce the risk ...

Страница 8: ...erial Never point the heating equipment towards compressed gas air cylinder or other pressure vessel 2 5 UV Radiation Hazards Please read understand and follow the safety instructions below in order to reduce the risk of injuries death and damage of properties due to UV radiation In addition ensure that every operator of the device follows the safety instructions Do not look directly into the ligh...

Страница 9: ...trictly prohibited Use of any outlet converter is also disallowed For any uncertainty please find a professional electrician to check whether the grounding is correct Please make sure the machine is well grounded to avoid the electric shock If the wire is damaged contact the manufacturer service provider or a professional to replace it in order to avoid injuries and accidents Please replace damage...

Страница 10: ...freely it can be adjustable from 20 cm to 220 cm UV 02 L or 240 cm UV 04 L 3 The desired drying time can be chosen by using an electronic timer 4 Both lamp cassette and main unit are cooled by fans 5 Different beep sounds to remind the operator of different situation of machine Accessory UV protective glasses Dustproof cover 3 1 Technical Data Model UV 02 L UV 04 L Input Voltage 50 60 Hz 230 V 230...

Страница 11: ...UV 02 L UV 04 L Page 7 equipment and facility engineering 3 2 Wiring Diagram UV 02 L UV 04 Technical changes and errors reserved All pictures similar ...

Страница 12: ...hreibung Art No No Beschreibung Art No 1 Front Wheels without Break 8 Control Panel 2 Rear Wheels with Break 9 Protective Glass 3 Pedestal 10 Lamp cassette 4 Column 11 Cable Hook 5 Handle 12 U shaoed Support 6 Adjustable Handle 13 Cross Arm 7 Pneumatic Cylinder Technical changes and errors reserved All pictures similar ...

Страница 13: ...UV 02 L The angle of the emitter cassette can be adjusted Caution When installing do not press the handle oft he pneumatic cylinder otherwise it may cause injury due to the rapid lifting of the cross arm Baking Area Technical changes and errors reserved All pictures similar ...

Страница 14: ...UV 02 L UV 04 L Page 10 equipment and facility engineering UV 04 L The angle of the emitter cassette can be adjusted UV 02 L UV 04 L Technical changes and errors reserved All pictures similar ...

Страница 15: ...low 1 Move the device and choose the optimal distance between emitter and car body The optimal distance is about 20 cm 2 Hold the air pressure handle to adjust the height of the emitter tube and the surface to be cured 3 Adjust the direction of the emitters They have to be aligned parallel to the car body 4 Press down the brake of the rear wheel to avoid any accident caused by the movement of the ...

Страница 16: ...r work reset curing time After time is up the fan in the lamp cassette will keep working for 1 minute to cool down and ozone blowing The beep sound switch has to be set permanently to on position Only in case of maintenance work it is allowed to switch it off Memory Operation The desired drying time can be set by using the corresponding buttons 2 By using the memory buttons the set time can be sav...

Страница 17: ... out the defect tube and fix the new tube with same model number and wire the tube properly 5 Install the protective glass radiating panel and the side panel Use a piece of soft cloth or cotton to clean the reflector panel and the tube with alcohol Cleaning must be conducted after the machine is disconnected with the power and cooled down You are not allowed to start the lamp tube until the alcoho...