INSTALLATION INSTRUCTIONS
3
M S D
• W W W . M S D P E R F O R M A N C E . C O M • ( 9 1 5 ) 8 5 5 - 7 1 2 3 • F A X ( 9 1 5 ) 8 5 7 - 3 3 4 4
Select from 10 to 60 Degrees.
(Default: 20)
Settings
:
Display: Adjust Contrast or
Brightness
Factory Defaults: Displays
factory defaults with the
option to reset current
settings.
Save Current Settings: Select
to Save current settings in
device.
Run Mode
:
Settings:
Speed A: 0 - 20000 RPM (1 RPM increments)
Speed B: 0 - 20000 RPM (1 RPM increments)
Speed Hold A: 0.0 -10.0 in seconds (0.1 second increments)
Speed Hold B: 0.0 -10.0 in seconds (0.1 second increments)
Ramp A to B: 0.0 -10.0 in seconds (0.1 second increments)
Ramp B to A: 0.0 -10.0 in seconds (0.1 second increments)
SETTINGS MENU
Adjustable settings, such as the crank type, duty cycle and Run Mode, can be calibrated for the
desired application. The display features can also be fine tuned for individual preferences.
To access the menu screen, press the knob for 2 seconds.
Crank Type:
Select desired crank type – 8CYL, 6CYL, 6-ODD, 4CYL, 12CYL, 1X, 24X, 58X,
12-1, or 35X. (Default 8CYL)
Duty Cycle (Points Output Only):
2
RPM
0
1
2
3
4 5 6
7
8
9
10
RPM
X 1000
6500
RPM
AUTO
8CYL
RPM
ACTIVATED
SWITCH
MSDPERFORMANCE.COM
PN 8950
2
Figure 4 Ignition Testing Via Points (White Wire)
UNIVERSAL
IGNITION
TESTER
MAGNETIC
PICKUP
(NOT USED)
CAM SYNC
(NOT USED)
WHITE
(POINTS)
GREEN (TACH)
TACH
SHIFT LIGHT
(PN8963/8952)
WHITE (TACH)
TACHOMETER
PN 8950
RED
BLACK
Speed A:
2000 RPM
Speed B:
5000 RPM
Speed Hold A:
5.0 sec
Speed Hold B: 7.0 sec
Ramp A to B:
3.0 sec
Ramp B to A:
6.0 sec
Figure 6 Run Mode Settings Example
B
A
SPEED
HOLD
‘A’
SPEED
HOLD
‘B’
RAMP
A TO B
RAMP
B TO A
SPEED
SPEED
Figure 5 Test Run Mode
BATTERY