INSTALLATION INSTRUCTIONS
3
LEDS
There are six LEDs on the end panel of the Controller. The Red status LED will be on steady when the
unit is turned On. Once the launch reset wire is activated (Dark Blue) this LED will blink rapidly (this
is handy during clutch setup). When the launch reset wire is deactivated the status LED will turn off.
The Green LEDs indicate each shift. Each LED will light up as the gearshift is activated. In Sequence-
On mode they stay on until the power is turned Off or the Launch Reset wire is activated again. In
Pulse mode each LED will blink for the gearshift.
If there is a shorted solenoid or an over heated solenoid
driver the status LED will blink a fault code to indicate
which solenoid output is at fault. The fault codes will
continue until the Launch Reset is active or the power
is turned off. The blink codes are:
Two blinks
Shift 1 output
Three blinks
Shift 2 output
Four blinks
Shift 3 output
Five blinks
Shift 4 output
Six blinks
Shift 5 output
WIRING
Figure 3 Shift LEDs.
Heavy Red
To Battery positive (+).
Heavy Black
To Battery negative (-) or other good ground.
Violet
To 12 volts at the ignition switch.
Dark Blue
Launch Reset input wire to +12 volts or ground.
Light Blue
Shift Override input wire to +12 volts momentary switch.
Pink
12 volt activation output for RPM Module Selectors.
Gray
Tach input, 12 volt signal from ignition.
Orange/Yellow
This is the signal wire for a shift light.
Fuse
Mini Blade, 20 Amp fuse.
Shift Solenoid Wires
Red Wires
These five wires provide the positive12 volts to each shift solenoid.
They are protected by a 20 Amp fuse.
Brown
Coil negative (-), Solenoid 1.
White
Coil negative (-), Solenoid 2.
Orange
Coil negative (-), Solenoid 3
Yellow
Coil negative (-), Solenoid 4.
Dark Green
Coil negative (-), Solenoid 5.
Red/Green
This wire provides the positive 12 volts to the Shift Light. Protected by
20 Amp fuse.