MSA ZGARD C Скачать руководство пользователя страница 1

 

 

 

 

   

 

 

 
Controllers

 

 

 

Instruction Manual  

 

WARNING

 

 

 

 

 

THIS MANUAL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE 
THE RESPONSIBILITY FOR INSTALLING, USING OR SERVICING THIS PRODUCT. Like any piece 
of complex equipment, this product will perform as designed only if installed, used and serviced in 
accordance with the manufacturer’s instructions. OTHERWISE, IT COULD FAIL TO PERFORM AS 
DESIGNED AND PERSONS WHO RELY ON THIS PRODUCT FOR THEIR SAFETY COULD 
SUSTAIN SEVERE PERSONAL INJURY OR DEATH. 
 

The warranties made by Mine Safety Appliances Company with respect to these Products are voided if the 
products are not installed, used and serviced in accordance with the instructions in this user guide. Please 
protect yourself and others by following them. We encourage our customers to write or call regarding this 
equipment prior to use or for any additional information relative to use or repair. 
 
 
 

Instrument Division 1-800-MSA-INST or FAX (412) 776-9783 
 
MSA International (412) 967-3228 or FAX (412) 967-3373 
 
In Canada 1-800-267-0672 or FAX (905) 238-4155 

 

© Mine Safety Appliances Company 2005 - All Rights Reserved 

 
MINE SAFETY APPLIANCES COMPANY 
PITTSBURGH, PENNSYLVANIA 15230 

 
 

 
 
 
 
 
 
 

 
REV 

1.2 August 

2008 

        

10063483 

Содержание ZGARD C

Страница 1: ...warranties made by Mine Safety Appliances Company with respect to these Products are voided if the products are not installed used and serviced in accordance with the instructions in this user guide...

Страница 2: ...ufacturers of such components THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED IMPLIED OR STATUTORY AND IS STRICTLY LIMITED TO THE TERMS HEREOF SELLER SPECIFICALLY DISCLAIMS ANY WARRANTY OF...

Страница 3: ...luded as part of the installation and as a routine inspection of the system 5 Use only genuine MSA replacement parts when performing any maintenance procedures provided in this manual Failure to do so...

Страница 4: ...g Specifications and Features 4 0 Installation and Set up Display Mode Number of Remote Sensor Inputs 4 1 Relay Function Setting up the Warning and Alarm Delays 4 2 Audible Alarm Device Setting Warnin...

Страница 5: ...ZGARD C Controllers This is a quick guide for determining the functionally capability and configuration of each controller ZGARD C CONTROLLER MODEL 1 CHANNEL 4 CHANNEL Number of Remote Sensors 1 4 Po...

Страница 6: ...controller according to the required application Also refer to the ZGARD C controllers Installation Outline drawings located in the back of this manual which provides important information regarding...

Страница 7: ...lue between 0 and 100 Full Scale FS Delay Function There are two user jumper selected methods for setting the ZGARD C 1 Channel controller warning and alarm delays The first uses pre programmed fixed...

Страница 8: ...ct the actual operating range of the incumbent remote gas sensors There are two display mode options A and B and is selected by placing Jumper H2 in the required position If jumper H1 4 is OUT Range A...

Страница 9: ...allows adjusting of the delays from 0 to 10 minutes via two potentiometers labeled Warning Delay Alarm Delay To select the adjustable delay jumper H1 5 is NOT inserted Removing the jumper activates t...

Страница 10: ...button will silence the audible alarm but will not have any effect on the alarm LED on the front panel or the alarm relay Warning and Alarm Set Points There are two methods for setting the warning an...

Страница 11: ...SPAN potentiometer can be used to perform these To adjust the output to 4 20mA for 0 100 input factory setting when using a 4 20mA type sensor apply a 0 4mA signal to the input and adjust the ZERO pot...

Страница 12: ...adjustable on the controller and can be set to any value between 0 and 100 Full Scale FS Delay Function There are two user jumper selected methods for setting the ZGARD C 4 Channel controller warning...

Страница 13: ...a special Display Range that displays the first two channels 1 2 as 0 10 0ppm and the second two channels 3 4 as 0 100ppm This is useful for Carbon Monoxide CO Nitrogen Dioxide NO2 applications Remote...

Страница 14: ...of the delays from 0 to 10 minutes via two potentiometers labeled Warning Delay Alarm Delay To select the adjustable delay jumper H1 5 is NOT inserted Removing the jumper activates the associated pot...

Страница 15: ...nce the audible alarm but will not have any effect on the alarm LED on the front panel or the alarm relay Warning and Alarm Set Points There are two methods for setting the warning and alarm set point...

Страница 16: ...can be used to perform these To adjust the output to 4 20mA for 0 100 input factory setting when using a 4 20mA type sensor apply a 0 4mA signal to one of the input and adjust the ZERO potentiometer...

Страница 17: ...RESET button to silence 7 Allow the associated remote gas sensors to stabilize Refer to the appropriate gas sensor manual for further details Depending on the controller s warning alarm and delay sett...

Страница 18: ...nuine MSA replacement parts when performing any maintenance on the ZGARD C Controllers Failure to do so may seriously impair instrument performance Repair or alteration of the ZGARD C controllers beyo...

Страница 19: ......

Страница 20: ......

Страница 21: ......

Страница 22: ......

Отзывы: