MSA PS-203-12.5 Скачать руководство пользователя страница 6

 

Operating manual 

 
 

v.0.3   

                                                                                       

 

Page 6

 

1.3.2

 

To 

connect 

input 

power 

supply, 

use 

terminals 

“L”  and  

“N”, loads – “–V” and “+V”, see Figure 2. 

 

Figure 2 – Connection diagram of the Product 

1.4

 

M

EASUREMENT INSTRUMENTS

,

 TOOLS AND APPLIANCES

 

Table 3 below describes consumables required for the TS. 

Table 3 – Consumables required for the TS 

Name and identifier of consumables 

Amount of consumables  

Note 

Cleaning cloth 

0.10 kg 

1

 

 To clean the Product surfac-

es – use clean cloth 
2

 

 To remove severe contami-

nation – use cloth soaked in 
alcohol 

Rectified hydrolytic technical ethyl alcohol 

0.05 l 

To soak cloth when removing 
contamination from a screen 

Varnish 

0.05 kg 

To cover surfaces of the Prod-
uct in case of paint coating 
damage 

Abrasive cloth 

0.06 х 0.06 m

 

To polish surfaces of the Prod-
uct  in  case  of  paint  coating 
damage 

1.5

 

M

ARKING AND SEALING

 

The Product has a nameplate indicating name, serial number, date of  manufac-

turing, weight, protection degree, input and output voltage, power. 

The sealing of the Product is not provided. 

Содержание PS-203-12.5

Страница 1: ...NPK Morsvyazavtomatica LLC 26E Kibalchicha Str St Petersburg Tel 8 800 100 67 19 info unicont com Russia 192174 Fax 7 812 362 76 36 www unicont com POWER SUPPLY UNIT PS 203 Operating manual...

Страница 2: ...1 6 Packaging 7 2 INTENDED USE OF THE PRODUCT 8 2 1 Operational limitations 8 2 2 Usage preparations 8 2 3 Usage of the Product 9 3 TECHNICAL SERVICE OF THE PRODUCT 10 3 1 General description 10 3 2...

Страница 3: ...t the safety regulations and rules applicable in the field shall be observed Only those who have read and understood this document and those who have had special training shall be permitted to operate...

Страница 4: ...use protects the Product against SC 1 2 2 Table 1 below describes technical specifications of the Product types Table 1 Technical specifications Parameter Type PS 203 12 5 PS 203 6 5 PS 203 3 3 Input...

Страница 5: ...ct Table 2 below describes functional elements and controls of the Product Table 2 Functional elements controls and LED light indicators of the Product Element Type size identifi er Description 1 Fuse...

Страница 6: ...clean the Product surfac es use clean cloth 2 To remove severe contami nation use cloth soaked in alcohol Rectified hydrolytic technical ethyl alcohol 0 05 l To soak cloth when removing contamination...

Страница 7: ...n a corrugated board box and inner packaging air bubble film ensuring its transportation and storage at the warehouse Transport packaging is also used as a returnable packaging for transportation of t...

Страница 8: ...for operation of electric installation and Safety rules for operation of electric installation while testing electrical circuits and insulation resistance 2 2 2 Visual check procedure Before switchin...

Страница 9: ...ng to OFF position b transfer circuit breakers of main power switchboard to OFF position c disconnect de energized power cable from the Product 2 3 USAGE OF THE PRODUCT To operate the Product a switch...

Страница 10: ...put voltage work is obligatory Table 5 CL 1 Visual check To be done Routine Man hours per 1 Product Visually examine the Product 1 Check completeness and appearance of the Product mechanical damage pa...

Страница 11: ...put terminals 1 person 15 mins 3 4 PRESERVATION The Product and set of operational documents are stored in preserved condition in Manufacturer s packaging boxes Time of represervation 2 years since th...

Страница 12: ...NOT switch on Under Operation when power supply switch is in OFF position Replacing defected parts cards and modules when power of device under repair is ON is STRICTLY PROHIBITED Installation commis...

Страница 13: ...onditions 5 to 40 with the concentration of dust oil moisture and aggressive impurities in the air within the required limits for the working areas of production facilities After storage or transporta...

Страница 14: ...n sealed and heated compartments sea transportation in dry service spaces The Product must be transported in compliance with transportation rules appli cable for each means of transport During loading...

Страница 15: ...send an over age equipment unit to the manufacturer for its further disposal Proper disposal of Product components allows avoiding possible negative envi ronmental and health impacts and it also allo...

Страница 16: ...t consider damage claims in case of violation of operating conditions More information about warranty terms you can find on the official site of NPK MSA LLC section Support Address and contacts of the...

Страница 17: ...Power supply unit PS 203 Page 17 APPENDIX A MANDATORY REGULATORY DOCUMENTS Figure A 1 Outline and installation dimensions of the Product...

Страница 18: ...Operating manual v 0 3 Page 18 FOR NOTES...

Страница 19: ...Power supply unit PS 203 Page 19 FOR NOTES...

Страница 20: ...Operating manual v 0 3 Page 20 FOR NOTES...

Отзывы: