6. Never alter or modify this device.
7. This respirator is for use by trained, qualified personnel only.
8. This facepiece does not provide any protection against propelled or

falling missiles. Consequently in riot or similar situations it is impera-
tive that a riot faceshield be worn in conjunction with the mask for pro-
tection against propelled or falling missiles.

FAILURE TO FOLLOW THE ABOVE WARNINGS CAN

RESULT IN SERIOUS PERSONAL INJURY OR DEATH.

Respirator Fit Test

A qualitative or quantitative respirator fit test must be performed for each wear-
er of this respirator to determine the amount of protection it will provide.
Respirator fit tests are explained fully in the American National Standard for
Respiratory Protection, ANSI Z88.2, which is published by the American
National Standards Institute, 11 West 42nd Street, New York, New York 10036.

Quantitative Test

If a quantitative fit test is used, a fit factor that is at least 1000 shall be obtained
before that respirator is assigned to an individual.

Qualitative Test

If a qualitative fit test is used, only validated protocols are acceptable. The indi-
vidual must pass a test designed to assess a fit factor of at least 1000.

The user must perform a respirator fit test and follow all warnings and limita-
tions specified. Failure to do so can result in serious personal injury or death.

PREPARATIONS FOR USE

There are five inspection points, listed below, that must be checked before
donning the respirator. Under no circumstances should a respirator that fails
inspection be used. The respirator must be repaired or replaced.

1. Head harness: Check to see that the head harness straps still have their

elasticity. Inspect for cracks or tears and make sure all buckles are in place
and working properly.

2. Facepiece: Check facepiece for dirt, cracks, tears or holes. Inspect the

shape of the facepiece for possible distortion that may occur from improp-
er storage and make sure the rubber is flexible, not stiff.

3. Inhalation and exhalation valves: Check for cracks, tears, distortion, dirt or

build-up of material between valve and valve seat.

4. Facepiece inlet port: Check to make sure gaskets are in place (if applicable)

and check for cracks and damage to threads.
a.

Inlet Port (Phalanx Beta only): Check to make sure gasket is in place
and check for traces of damage to inlet components.

b.

Inlet Port (Phalanx Alpha only): Check to make sure the inlet port
threads are free of damage such as crossed threads and that the can-
ister sealing surface of the facepiece is clean and free of dirt or other
foreign matter. Make sure the inlet port plugs are in place on the side of
facepiece opposite the canister.

TAL 704 (L) Rev. 11 - 487373

3

WARNING

Содержание Phalanx Alpha

Страница 1: ...under the 42 CFR 84 P100 classification 99 97 efficiency level against all particulate aerosols including oil based aerosols NIOSH approval See inside for instructions warnings and limitations See separate insert for NIOSH Approval Matrix Phalanx Alpha Phalanx Beta and Ultra Elite TAL 704 L Rev 11 MSA 2007 Print Spec 10005389 F Mat 487373 Doc 487373 ...

Страница 2: ...es vapors NIOSH approved for CN chloroacetophenone and CS chlorobenzylidene malononitrile and all particulate aerosols including oil based aerosols listed on the canister label from the inhaled air Inhaled air is drawn through the canister which con tains chemicals and a P100 filter that removes or neutralizes the contaminants The air is then drawn through the facepiece where it passes over the le...

Страница 3: ...w all warnings and limita tions specified Failure to do so can result in serious personal injury or death PREPARATIONS FOR USE There are five inspection points listed below that must be checked before donning the respirator Under no circumstances should a respirator that fails inspection be used The respirator must be repaired or replaced 1 Head harness Check to see that the head harness straps st...

Страница 4: ...akage is detected around the facial seal readjust head harness straps and repeat test until there is no leakage If other than facial seal leakage is detected the condition must be investigated and corrected before another test is made The facepiece must pass the tightness test before the user should attempt to enter any toxic atmosphere The mask will not furnish protection unless all inhaled air i...

Страница 5: ...This mask must be kept in good condition to function properly When any part shows evidence of failure it must be replaced immediately with the proper part CLEANING AND DISINFECTING The facepiece assembly with canister removed should be cleaned after each use with MSA Cleaner Disinfectant Liquid P N 697284 maximum 120 F 1 Immerse soiled equipment in the solution and scrub gently with a soft brush u...

Страница 6: ... determine or check with the safety office to verify that the protective equipment to be used is sufficient for exposure to their particular hazard and contamination level Mis use of the protective equipment can result in serious personal injury or death During the Stay in the CBA Contaminated Area 1 It is recommended that the area be real timed monitored with alarm for exposure levels of the cont...

Страница 7: ...Failure to follow accepted safety and protection procedures when exposed to hazardous atmospheres can result in serious personal injury or death WARNING TAL 704 L Rev 11 487373 7 ...

Страница 8: ...8 TAL 704 L Rev 11 487373 817589 634323 ...

Страница 9: ...634623 TAL 704 L Rev 11 487373 9 ...

Страница 10: ...10 TAL 704 L Rev 11 487373 ...

Страница 11: ...TAL 704 L Rev 11 487373 11 NOTES ...

Страница 12: ......

Страница 13: ...1 TAL 7921 L Rev 9 DRAFT 12 15 97 ...

Страница 14: ...1 TAL 7921 L Rev 9 DRAFT 12 15 97 ...

Отзывы: