13.1 Quick Connect Fitting Instructions
The G1 ExtendAire II System contains two quick connect fittings, capable of connecting with both
male and female fittings on another user's manifold.
WARNING!
DO NOT install or attempt to use any hose assembly or fitting other than those supplied by MSA for
the G1 ExtendAire II System. Misuse can result in serious injury or death.
(1) Quick connect fittings require a single action to connect:
Push the coupler firmly over the plug to engage.
(2) Quick connect fittings require two actions to disconnect:
a) Push the two sides of the quick connect towards each
other. The plug should advance into the coupler end an
additional 1/8".
b) Slide the coupler's outer sleeve away from the plug.
Pull the plug out of the coupler. Ensure that the
quick connect plug on the manifold black is protected
by the supplied dust cap.