9. Install the screw and

tighten using a small
phillips screwdriver.

Rubber must not extrude between the component
housing ring ends at the joint. If this happens,
reassemble.

10. Re-install the nosecup or air baffle (if used) in the

facepiece.

11. Re-install the component housing cover and adapter

assembly.

12. Don the facepiece and check the face-to-facepiece

seal. Follow the Facepiece Fit Check.

REPLACING THE SPEAKING DIAPHRAGM

1. Remove the nosecup or air baffle (if installed) from

inside the facepiece.

2. Unscrew and remove

the speaking
diaphragm retaining
ring.

3. Turn the facepiece upside down and shake out the

metal speaking diaphragm and gasket assembly.

4. Check the speaking diaphragm and gasket assembly

for damage. Replace it if it is worn or damaged.

5. Be sure that the gasket is on the diaphragm assembly.

Place the diaphragm in the retaining ring. Be sure that
the gasket side of the speaking diaphragm will be fac-
ing the component housing.

6. Replace the retaining ring and hand-tighten.
7. Re-install the nosecup or air baffle (if used) in the

facepiece.

8. Don the facepiece and check the face-to-facepiece

seal. Follow the Facepiece Fit Check.

REPLACING THE INLET GASKET AND DISC VALVE

1. Remove the component housing cover and the

adapter assembly.

2. Remove the disc from the gasket and inspect both for

wear. The disc should be very soft and pliable. Install
a new disc valve if it is damaged or hardened.

3. To install the inhalation disc valve:

a.

Gently,

stretch the hole in the center of the disc

valve over the gasket stem.

b. Note that the inlet

gasket has a groove
around its inside.

c. With the pull-tab facing you, insert the gasket into

the facepiece at an angle so that its groove cap-
tures the housing rim. The lower lip on the gasket
must be placed under the rim in the component
housing.

Note:

It may be necessary to bend the gasket slightly to

work the groove under the rim all the way around. When
installed correctly, the gasket will lay flat in the housing,
and none of the spokes will be bent.

4. Re-install the adapter assembly.
5. Don the facepiece and check the face-to-facepiece

seal. Follow the Facepiece Fit Check.

ULTRA ELITE FACEPIECE COMPONENT HOUSING
INSPECTION

Note:

Ultra Elite Facepieces can be identified by a mold-

ed emblem in the forehead area containing the word
“Ultra Elite”.

See User’s Instructions for additional illustrations and
information.

Inspect the component housing on Ultra Elite Facepieces
manufactured from July to December 2003 using the pro-
cedure below.

To locate the date code:

1. Hold the Ultra Elite Facepiece in one hand.
2. Gently pull the chin cup toward you.
3. Under a good light source, locate the stamped circle

on the inside, right side of the facepiece.

10

TAL 805 (L) Rev. 4 - 10042830

Содержание FireHawk Ultra Elite 10048813

Страница 1: ...Ultra Elite Facepiece TAL 805 L Rev 4 MSA 2008 Prnt Spec 10000005389 I Mat 10042830 Doc 10000015248 MAINTENANCE AND REPAIR...

Страница 2: ...811 Component Housing Ring 14 804812 Screw Kit 15 10018621 Slide Adapter Ass y 15a 10033115 Push To Connect Adapter Ass y 15b 813556 1 4 Turn Adapter Ass y 17 804829 Neckstrap 18 815604 Component Hous...

Страница 3: ...10042830 ULTRA ELITE FACEPIECE 7a 7 7b 15b 23 24 3 12 27 in lbs pressure demand facepiece NFPA Facepiece Components Type Small Medium Large Hycar 10048814 10048813 10048815 Silicone 805581 805580 8055...

Страница 4: ...4 TAL 805 L Rev 4 10042830...

Страница 5: ...operly Note Do not force dry the parts by placing them in a heater or in direct sunlight The rubber will deteriorate When the facepiece is thoroughly dry store the facepiece in the plastic bag that it...

Страница 6: ...ng freeing retainer from slots in the housing Lift the retainer and the spring out of the component hous ing Discard spring and spring retainer Be careful not to damage the slots or valve seat in the...

Страница 7: ...he octagon flange on the adapter b Thread the adapter assembly into the facepiece Use the spanner wrench to torque the adapter to 12 27 in lbs If necessary continue to torque until the top flat on the...

Страница 8: ...the groove Work the face piece rubber flange around the lens to fully seat the lens in the groove When installed correctly the bottom lens center line mark lines up with the bottom face piece center...

Страница 9: ...ea and the inside of the housing ring 4 Insert the narrow end of the ring into the space between the lower lens ring and the facepiece housing area 5 Line up the component housing ring mark with the f...

Страница 10: ...2 Remove the disc from the gasket and inspect both for wear The disc should be very soft and pliable Install a new disc valve if it is damaged or hardened 3 To install the inhalation disc valve a Gen...

Страница 11: ...Housing Cover and Adapter 1 Gently stretch the hole in the center of the inlet disc valve over and onto the gasket stem 2 With the pull tab facing outward insert the gasket into the facepiece at an an...

Страница 12: ...ontinue to tighten until the top flat of the adapter octagon is horizontal Note The octagon flats on the facepiece adapter must align with octagon flats of component housing d Press in on the front of...

Страница 13: ...pter through the facepiece component housing cover Thread the adapter assembly into the facepiece 3 Tighten facepiece adapter until the top flat on the octagon is horizontal Note The octagon flats on...

Страница 14: ......

Отзывы: