FIREHAWK RESPONDER SECOND STAGE REGULATOR
2. Push the valve into the regulator housing.
Installing the Bypass Screen
Bypass Screen
P/N 10082485
O-Ring
P/N 632736
1. Insert a new screen
(P/N 10082485).
a. Ensure that the
screen seats all
around the periphery.
2. Protect the o-ring from
the thread with tape or
thin pieces of paper.
3. Apply a small amount of Christo-Lube (P/N 604070) to
a new o-ring (P/N 632736)
4. Install the o-ring.
5. Remove the protective tape or paper.
6. Carefully screw the
nipple into the hose
union.
7. Use a
3/4” wrench
to
hold the hose union
and a
3/4” crowfoot
and inch pound torque
wrench
to tighten the
nipple to
75 ± 5 in lbs.
Assembling the Bypass Assembly
Bypass Stem
P/N 10082482
O-Ring
P/N 10082488
1. Install the bypass stem.
a. Apply a small amount of Christo-Lube (P/N 604070)
to the o-ring.
b. Install the o-ring
(P/N 10082488) on
the bypass stem
(P/N 10082482).
c.
Insert the bypass stem.
10