EVOLUTION 6000 Thermal Imaging Camera
36
Camera Setup
MSA
US
Display
Brightness
Sets display brightness or
allows for auto brightness
control.
(1)
SCROLL to Set Brightness Auto and SELECT to ena-
ble auto brightness control.
Auto brightness automatically adjusts screen
brightness in three levels, depending on ambient
light.
The ambient light sensor is to the right of the battery
status indicator.
(2)
To set the screen brightness to low, medium or high,
SCROLL to:
Set to Low
Set to Med or
Set to High
(3)
and SELECT.
Selection is confirmed and camera returns to the Config
main menu.
Range Find-
er
Units (feet or meters) selec-
tion for the range finder
(1)
SCROLL to:
Set to Feet or
Set to Meters,
(2)
and SELECT.
Selection is confirmed and camera returns to the Config
main menu.
Video Xmit - Turning optional video trans-
mitter ON and OFF, and se-
lecting the channel (if local
control was not disabled via
the MSA FireService Utility
package)
(1)
To turn video transmitter ON or OFF, SCROLL to
Set Video Xmit ON or
Set Video Xmit OFF
Camera front panel video transmit LED illuminates.
(2)
To choose one of the two available video channels,
SCROLL to:
Set Channel to A or
Set Channel to B.
NOTE: Two camera video transmitters in the same approx-
imate area cannot operate on the same channel at the
same time.
Selections are confirmed.
Camera returns to the Config main menu.
Video
Record
Turning optional video re-
corder ON and OFF (if local
control has not been disa-
bled via the MSA FireService
Utility package).
(1)
To turn video recording ON or OFF, SCROLL to:
Set Video Recorder ON or
Set Video Recorder OFF.
Selection is confirmed and camera returns to the Config
main menu.
Option
Description