Operating Manual
10
Figure 3 – The Product’s connection diagram
1.3.2.4
Load may have direct and switched connection to SB, see Figures 4–5,
respectively.
Direct type of connection is used for loads with consumption current more than
30 А, i.e., power exceeds maximum permissible for the Product.
Switched connection is used for loads with max. consumption current 30 А.
Switched type of connection allows for using SB deep discharge protection
function, see. 2.3.7. Enable (disable) this function in the Product menu, see 2.3.2.
Selected type of connection (direct or switched), as well as switching of connec-
tion type may lead to the limited use of some functions or change the Product’s opera-
tion.
Note – Voltage of the Product «Output 12/24 VDC» terminal, see Figures 3–6,
is directly connected to voltage of SB connected to Product «BATTERY» terminal, see
Figures 3–6; thus, if SB with voltage 12 V is connected to charger, voltage of «Out-
put 12/24 VDC» terminal is 12 V; if SB with voltage 24 V is connected to charger,
voltage of «Output 12/24 VDC» terminal is 24 V.
Figure 4 – Diagram of load to SB direct connection
Содержание CH-105