COMPRESSED AIR CYLINDERS WITH ALPHACLICK 2
MSA
32
AirMaXX classic
5.2. Filling of Compressed Air Cylinders with
alphaCLICK 2
Fig. 20
Filling station for compressed air cylinders with alphaCLICK 2
1
Compressed air cylinder with alphaCLICK 2 cylinder adaptor
2
Operating lever
3
Blind plug
4
alphaCLICK 2 filling coupling
5
Cylinder adaptor
With the help of the filling panel, it is possible to fill several compressed air
cylinders quickly and safely at the same time. Time-consuming screwing-on of
compressed air cylinders is no longer required thanks to
alphaCLICK 2
. The
compressed air cylinder is simply plugged into the
alphaCLICK 2
filling coupling
of the filling panel.
The compressed air cylinders are filled with the help of an operating lever which
has to be operated depending on the design of the filling panel for each individual
cylinder or centrally for the station.
Warning!
When filling air cylinder(s) using the filling panel, secure non used
alphaCLICK 2
filling
couplings with a blind plug.
Do not pressurise a non-used
alphaCLICK
2
filling coupling without a
blind plug.
This can cause damage to persons and objects.
(1) Release pressure from the filling panel.
(2) Remove the blind plug from the
alphaCLICK 2
coupling on the filling panel.
(3) Attach the compressed air cylinder to the
alphaCLICK 2
coupling and open
the cylinder valve.
1
2
3
5
4