MS Sedco DH100-CT Скачать руководство пользователя страница 8

Section 13

External Dimensions

Section 14

Warranty

MS SEDCO guarantees this product to be free from manufacturing 

defects for 3 years from date of installation.  Unless MS SEDCO is 

notified of the date of installation, the warranty will be in effect for 

3 years from the date of shipment from our factory.  If, during the 

first 3 years, our motion detector or support device fails to operate 

and has not been tampered with our abused, the unit can be 

returned prepaid to factory and it will be repaired free of charge.  

After 3 years, the unit will be repaired for a nominal service charge.  

This limited warranty is in lieu of all other warranties expressed 

or implied, including any implied warranty of merchantability, 

and no representative or person is authorized to assume for MS 

SEDCO any other liability in connection with the sale of our 

products.  All warranties are limited to the duration of this 

written warranty.  In no event shall MS SEDCO be liable for any 

special, incidental, consequential or other damages arising from 

any claimed breach of warranty as to its products or services.

Page 8

(/MANU) DH100-CTv1017

Sliding Pedestrian Door Motion & Presence Sensor 

INSTALLATION INSTRUCTIONS

DH100-CT

7898 Zionsville Road 

 Indianapolis, Indiana 46268

Telephone: (317) 842-2545 

 www.mssedco.com 

 [email protected]

75mm(2.95")

 

=

 

Standard

 

Mounting

 

Pitch

25mm

(0.98")

15mm

(0.59")

35mm

(1.37")

10mm

(0.39")

230mm(9.06")

44mm

(1.73")

70

.4

 

m

m

(2

.7

7"

)

66

.5

 

m

m

(2

.6

2"

)

33.5

 

mm

(1.32")

Содержание DH100-CT

Страница 1: ...m 2 Mount within 50mm 1 97 from bottom of header cover 3 Do not leave any objects which may move in the detection pattern 4 Avoid steamy environments 5 Ensure rain or snow will not fall directly on unit 6 Ensure snow or water can not accumulate on floor 7 Ensure a minimum of reflected sunlight from the floor 8 Use different frequency settings for sensors in close proximity Accessories Use Alternat...

Страница 2: ... each sensor to prevent interference Safety Relay Output Refer to Timing Chart of events for full details on Safety Output Reflection Diagnostics A low reflected infrared signal is indicated by a slow flashing Red Green LED To ignore this low reflection Low Reflection ON Default Setting Page 2 MANU DH100 CTv1017 DH100 CT Sliding Pedestrian Door Motion Presence Sensor INSTALLATION INSTRUCTIONS 7898...

Страница 3: ...wer BEFORE APPLYING POWER READ AND FOLLOW THESE INSTRUCTIONS When power is applied the sensor will read and store the environmental optical parameters This is necessary for Presence Detection to work properly 1 CLEAR THE AREA OF ANY UNNECESSARY OBJECTS 2 Apply POWER 3 Vacate the Detection Pattern immediately While the sensor sees ANY moving objects in its DETECTION PATTERN it will not proceed to t...

Страница 4: ...ing the Doorway Learn process the outer 4 rows of detection on the DH100 CT sensor switch from motion detection to presence detection 10 seconds after power ON The inner Doorway Learn row of detection will switch from motion to presence detection after the Doorway Learn process is complete Doorway Learn Failure Recovery If a person enters the detection area during the Doorway Learn process it may ...

Страница 5: ...Presence Sensor INSTALLATION INSTRUCTIONS DH100 CT 7898 Zionsville Road Indianapolis Indiana 46268 Telephone 317 842 2545 www mssedco com custsvc mssedco com Inner 3 rows adjustment lever arm Door Door 8 degree setting 0 degree setting With Base 1 0m 3 3 1 5m 4 9 0 5m 1 6 1 0m 3 3 1 5m 4 9 0 5m 1 6 3 3 1 0m 6 6 2 0m 7 2 2 2m 9 8 3 0m 1 0m 3 3 Door Door Without Base 8 degree setting 0 degree settin...

Страница 6: ...sensor If the error persists set Dip Switch 8 to Low Reflection Section 11 Troubleshooting PROBLEM 1 Door does not open when person enters the detection area LED STATUS OFF CAUSE 1 Sensor Connector SOLUTION 1 Tighten connector or reconnect CAUSE 2 Power Supply SOLUTION 2 Check that the power supply is properly connected and 12V to 24V AC or DC CAUSE 3 Sensor Wiring SOLUTION 3 Double check sensor w...

Страница 7: ...g and Angle Adjustment Levers Outer 2 Rows 10 in 3 steps Inner 3 Rows 8 in 3 steps Pattern Width via 2 Position Mechanical Mask Knobs Outer 2 Rows Narrow or Wide Inner 3 Rows Single or Double Door Sensitivity via potentiometer Detection Beams UP TO 48 BEAMS Inner 2 Rows 12 Beams x 2 Rows Outer Rows 8 Beams x 3 Rows Presence Detection 1 2 3 Inner Rows safety timer selectable 2 30 60 sec and infinit...

Страница 8: ... all other warranties expressed or implied including any implied warranty of merchantability and no representative or person is authorized to assume for MS SEDCO any other liability in connection with the sale of our products All warranties are limited to the duration of this written warranty In no event shall MS SEDCO be liable for any special incidental consequential or other damages arising fro...

Страница 9: ...llow Blue Yellow Blue Yellow Blue Yellow Blue Yellow Blue Yellow Blue Yellow Blue Yellow Blue Safety Output Row 1 2 Test Input Activation Output Row 2 3 4 5 1 2 3 4 5 Yellow Blue Yellow Blue TEST NON TEST NON TEST OFF 6 ON 7 N C Dip Switch X Dip Switch Y NON DETECTION POWER OFF 1 2 3 4 5 DETECTION White Green White Green White Green White Green White Green White Green 1 2 3 4 5 1 2 3 4 5 2 N C Dip...

Отзывы: