MS Sedco DH100-CT Скачать руководство пользователя страница 1

DH100-CT

Sliding Pedestrian Door Motion & Presence Sensor 

INSTALLATION INSTRUCTIONS 

Page 1

(/MANU) DH100-CTv1017

Section 1

General Description

The DH100-CT is an active infrared presence sensor that 

is designed to provide both activation and safety 

detection for automatic sliding and folding doors in a 

single device. 

• Test Input provides sensor monitoring 

  capabilities as required by the latest

  industry standard. 

• Pattern depth and width are 

  adjustable using mounting height,

  dip switches, detection area depth,

  and detection area width adjustments.

• Frequency can be changed to prevent interference 

  from other sensors in close proximity.

• Self-Diagnostic means the sensor continuously 

  monitors itself.

• Monitor Mode Switch ensures against false operation 

  caused by snow, leaves, insects, etc.

• Programmable Presence Timer (2 sec., 30 sec., 

  60 sec., or infinity).

Section 2

Parts Identification

Section 3

Mounting Information

1.  Do not mount higher than 9.84 ft. (3m).

2.  Mount within 50mm (1.97”) from bottom of header 

 cover.

3.  Do not leave any objects which may move in the 

  detection pattern.

4.  Avoid steamy environments.

5.  Ensure rain or snow will not fall directly on unit.

6.  Ensure snow or water can not accumulate on floor.

7.  Ensure a minimum of reflected sunlight from the 

 floor.

8.  Use different frequency settings for sensors in close 

 proximity.

Accessories

Use Alternat

e F

requency.

1

3

2

3

4

5

6

A

B

7

NOTE: 

 Set up for this sensor should be 

performed by an AAADM-certified installer.

7898 Zionsville Road 

 Indianapolis, Indiana 46268

Telephone: (317) 842-2545 

 www.mssedco.com 

 [email protected]

To maximize the effectiveness of door

w

ay detection,

install the DH100-CT outside and inside as sho

wn 

belo

w

A          B 

Side Vi

e

w

Plan Vi

e

w

M

oving Door Leaf

M

oving Door Leaf

Max

 

50mm

3.0m

 

(9.84ft)

Cover

Indicator

 

LED

(Red,

 

Green

 

&

 

Blue)

Base

Area

 

Mask

(Inner

 

3

 

Rows)

Area

 

Mask

(Outer

 

2

 

Rows)

Detection

 

Window

Potentiometer

(Sensitivity

 

Volume)

Connector

Depth Adjustment

Lever Arm

(Inner 3 Rows)

Depth Adjustment

Lever Arm

(Outer 2 Rows)

Dip

 

Switch

Dip

 

Switch

X

Y

Installation

 

Instruction

Mounting

 

Template

Cable

Mounting

  

Screws

 

(2

 

pcs.)

(1.97”)

Содержание DH100-CT

Страница 1: ...m 2 Mount within 50mm 1 97 from bottom of header cover 3 Do not leave any objects which may move in the detection pattern 4 Avoid steamy environments 5 Ensure rain or snow will not fall directly on unit 6 Ensure snow or water can not accumulate on floor 7 Ensure a minimum of reflected sunlight from the floor 8 Use different frequency settings for sensors in close proximity Accessories Use Alternat...

Страница 2: ... each sensor to prevent interference Safety Relay Output Refer to Timing Chart of events for full details on Safety Output Reflection Diagnostics A low reflected infrared signal is indicated by a slow flashing Red Green LED To ignore this low reflection Low Reflection ON Default Setting Page 2 MANU DH100 CTv1017 DH100 CT Sliding Pedestrian Door Motion Presence Sensor INSTALLATION INSTRUCTIONS 7898...

Страница 3: ...wer BEFORE APPLYING POWER READ AND FOLLOW THESE INSTRUCTIONS When power is applied the sensor will read and store the environmental optical parameters This is necessary for Presence Detection to work properly 1 CLEAR THE AREA OF ANY UNNECESSARY OBJECTS 2 Apply POWER 3 Vacate the Detection Pattern immediately While the sensor sees ANY moving objects in its DETECTION PATTERN it will not proceed to t...

Страница 4: ...ing the Doorway Learn process the outer 4 rows of detection on the DH100 CT sensor switch from motion detection to presence detection 10 seconds after power ON The inner Doorway Learn row of detection will switch from motion to presence detection after the Doorway Learn process is complete Doorway Learn Failure Recovery If a person enters the detection area during the Doorway Learn process it may ...

Страница 5: ...Presence Sensor INSTALLATION INSTRUCTIONS DH100 CT 7898 Zionsville Road Indianapolis Indiana 46268 Telephone 317 842 2545 www mssedco com custsvc mssedco com Inner 3 rows adjustment lever arm Door Door 8 degree setting 0 degree setting With Base 1 0m 3 3 1 5m 4 9 0 5m 1 6 1 0m 3 3 1 5m 4 9 0 5m 1 6 3 3 1 0m 6 6 2 0m 7 2 2 2m 9 8 3 0m 1 0m 3 3 Door Door Without Base 8 degree setting 0 degree settin...

Страница 6: ...sensor If the error persists set Dip Switch 8 to Low Reflection Section 11 Troubleshooting PROBLEM 1 Door does not open when person enters the detection area LED STATUS OFF CAUSE 1 Sensor Connector SOLUTION 1 Tighten connector or reconnect CAUSE 2 Power Supply SOLUTION 2 Check that the power supply is properly connected and 12V to 24V AC or DC CAUSE 3 Sensor Wiring SOLUTION 3 Double check sensor w...

Страница 7: ...g and Angle Adjustment Levers Outer 2 Rows 10 in 3 steps Inner 3 Rows 8 in 3 steps Pattern Width via 2 Position Mechanical Mask Knobs Outer 2 Rows Narrow or Wide Inner 3 Rows Single or Double Door Sensitivity via potentiometer Detection Beams UP TO 48 BEAMS Inner 2 Rows 12 Beams x 2 Rows Outer Rows 8 Beams x 3 Rows Presence Detection 1 2 3 Inner Rows safety timer selectable 2 30 60 sec and infinit...

Страница 8: ... all other warranties expressed or implied including any implied warranty of merchantability and no representative or person is authorized to assume for MS SEDCO any other liability in connection with the sale of our products All warranties are limited to the duration of this written warranty In no event shall MS SEDCO be liable for any special incidental consequential or other damages arising fro...

Страница 9: ...llow Blue Yellow Blue Yellow Blue Yellow Blue Yellow Blue Yellow Blue Yellow Blue Yellow Blue Safety Output Row 1 2 Test Input Activation Output Row 2 3 4 5 1 2 3 4 5 Yellow Blue Yellow Blue TEST NON TEST NON TEST OFF 6 ON 7 N C Dip Switch X Dip Switch Y NON DETECTION POWER OFF 1 2 3 4 5 DETECTION White Green White Green White Green White Green White Green White Green 1 2 3 4 5 1 2 3 4 5 2 N C Dip...

Отзывы: