WMPD2 · WMPAD2 · WMPAD2-L

4

Installation

All electrical installation and maintenance must be carried out by a competent person. If in doubt, 

consult a qualified electrician. Any new wiring must be carried out by qualified personnel in 

accordance with the current edition of the IET Wiring Regulations (BS7671).

!

 

Ensure the electrical supply is isolated before making any connections or adjustments.

!

1.  Select a suitable location for the unit (following the guidelines under 

Positioning

) and 

prepare a single-gang pattress or back box as necessary.

2. 

The unit contains a battery, which must be switched on prior to use. Using e.g. a small 

screwdriver, move 

Switch 1

 to the ‘ON’ position as indicated on the accompanying label.

3. 

Adjust the controls according to the operational requirements.

−  Rotate the 

Timeout

 and 

Lux Level

 thumbwheels to the desired settings. For non-

lighting loads, ensure the latter is set correctly. See 

Controls

 below. 

WMPAD2-L only

 The button illumination LED may be used to assist setup of the 

Lux 

Level

 control: see 

LED Indicator

 below.

− 

WMPAD2(-L)

 Use 

Switch 2

 to select the desired operating mode: see 

Controls

 below. 

WMPD2 only

 

Switch 2

 is not used and should not be adjusted.

4. 

Connect the wiring as shown in Figure 2 (or in any suitably appropriate form) using 

mains cable having a current rating appropriate to the load.

5.  Fix the unit into position with the two screws and caps supplied. 

Controls

• 

Timeout

 (10 seconds to 60 minutes): Sets the period of time over which no motion must 

be detected, after which the load is switched off.

• 

Lux Level:

 Sets the ambient light level threshold, below which the unit will permit 

activation upon detecting motion. For non-lighting loads, and in other cases where 

operation should be permitted at any light level, turn the control fully towards ‘Light’.

• 

Operating Mode 

WMPAD2(-L)

:

 Select either 

Presence Mode (‘Pres.’)

 or 

Absence Mode 

(‘Abs.’)

. See 

Operation

 for details.

 

Additional Guidelines

•  If the unit will be disconnected from the mains supply for an extended period, return 

Switch 1

 to the ‘OFF’ position until it is next required.

•  The screw caps may be removed at a later date with the aid of an adhesive putty such 

as Blu-Tack.

 

LED Indicator 

WMPAD2-L only

The LED indicator lights when the load is off, 

and the ambient light is below the threshold

 

set by the 

Lux Level

 thumbwheel. As well as aiding location of the unit in darkness (when 

used in 

Absence Mode

), it can be used to check that the 

Lux Level

 setting is appropriate. 

The electrical supply to the unit MUST be isolated before making adjustments.

Содержание WMPD2

Страница 1: ...D2 L today tomorrow and in the future mselectronics co uk Wall Mounted Presence Absence Detectors 2 wire versions WMPD2 Presence Detector WMPAD2 Presence Absence Detector WMPAD2 L with LED indicator e...

Страница 2: ...D2 Presence Detector offers fully automatic operation switching on the load upon detection of motion and switching off when the area has been unoccupied for the set period The WMPAD2 Presence Absence...

Страница 3: ...re that the intended load and wiring arrangement comply with the following requirements Figure 2 shows a typical wiring example 2 wire live load connection The unit connects inline with the load and i...

Страница 4: ...d not be adjusted 4 Connect the wiring as shown in Figure 2 or in any suitably appropriate form using mains cable having a current rating appropriate to the load 5 Fix the unit into position with the...

Страница 5: ...If the unit does not respond to motion during testing remember that the ambient light level must be low enough with respect to the Lux Level setting to permit activation The Lux Level setting only af...

Страница 6: ...e has been run between the switch locations noting that only two of the cores are needed Each unit detects motion independently and operates its own timing cycle but the load is shared When either or...

Страница 7: ...ctor b Unit is not set up correctly WMPAD2 L Ensure the operating mode has been selected appropriately In Absence Mode the override button must be used to switch on the load Wait 1 minute after connec...

Страница 8: ...onics co uk or call 0333 666 1176 Alternatively email techsupport mselectronics co uk Additional copies of this product guide can be downloaded from our website Product Warranty MS Electronics guarant...