Appendix D - Cabling the LX-8000 Series
56
MRV Communications, Inc.
www.mrv.com
451-0331
10/100 Connector
Figure 17 shows the standard 10/100 (RJ-45 jack) connector signal assignments.
Figure 17 - 10/100 Connector Assignments
Ordering Cables
MRV also supplies crossover cables and modular adapters for use with all LX-8000 Series units. To
order cables, adapters or other cabling accessories from MRV, contact your Sales representative or
distributor.
Modular Adapters
MRV provides the following modular adapters for use with LX-8000 Series units:
•
Female DB-9 (PN MX-350-0308)
•
Female DB-25 (PN MX-350-0181)
•
Male DB-25 (PN MX-350-0179) – supports RING
•
Male DB-25 (PN MX-350-0180) – supports RTS/CTS
This section describes the pinouts and wiring of the MRV-supplied DB-25 adapter.
Pin Assignments
The following table shows the pinouts for the DB-25 cable.
Pin
Signal
1
Cable Shield
2
Transmit Data
3
Receive Data to DCE
4
RTS (Request to Send)
5
CTS (Clear to Send)
6
DSR (Data Set Ready)
7
Signal Ground
8
Data Carrier Detect
8 7 6 5 4 3 2 1
Pin Signal
1 TX+
2 TX-
3 RX+
4 No Connect
5 No Connect
6 RX-
7 No Connect
8 No Connect
Содержание LX-8000 Series
Страница 4: ...4 MRV Communications Inc www mrv com 451 0331 ...
Страница 8: ...8 MRV Communications Inc www mrv com 451 0331 ...
Страница 10: ...10 MRV Communications Inc www mrv com 451 0331 ...
Страница 24: ...Installing the LX 8000 Series 24 MRV Communications Inc www mrv com 451 0331 ...
Страница 44: ...Alternative Port Capabilities 44 MRV Communications Inc www mrv com 451 0331 ...
Страница 48: ...Appendix A Technical Specifications 48 MRV Communications Inc www mrv com 451 0331 ...