EM316LNXNM-OT
Configuration Context
PN 1275005-100 Rev E6
53
There must always be at least one SUPER class user configured in the system. If there is only one SUPER
class user on the system, it cannot be deleted. Even the built-in "admin" user may be deleted if another
SUPER user is added first.
The example below adds a new user "david2" with the password "david2pw".
fiberdriver(config)# username david2 password david2pw
fiberdriver(config)#
fiberdriver(config)#
fiberdriver(config)# show users
username admin password encrypted $1$kQ2rIq/$Ob8wFa235XC4TnN7wJ/ class super
username admin groups all
username david2 password encrypted $1$ER4TU/7.$m/4mcdXwlOjM/LVEHW.
fiberdriver(config)#
The system does not automatically save configurations to permanent storage. Use the write file command to
save a configuration before restarting the system. Unsaved changes are lost, including new user accounts!
6.7.2. Password Strength
Descriptive error messages give helpful information when a password does not meet the system
requirements. Passwords created must meet be:
• at least 6 characters long
• at least one alphabetic character
• at least one non-alphabetic character
The commands below remove and re-apply the password strength restrictions above.
fiberdriver(config)# no sys password-strength-checking
fiberdriver(config)#
fiberdriver(config)# sys password-strength-checking