12.5. Trap Filtering
Traps can be filtered by chassis, slot, or port with the
trap
command.
Enable all traps for the target device with the
trap
command. Use a trap name as an argument to enable
only a specific trap.
fiberdriver(chassis/1)# trap?
trap - Enable trap generation
fiberdriver(chassis/1)# trap ?
<cr> - Enable all available traps for this location
> - Redirect output to a file
>> - Append output to file
NAME - Enable generation of a specific trap
fiberdriver(chassis/1)#
Disable all traps for the device with the
no trap
command. Use a trap name as an argument to disable
only a specific trap.
fiberdriver(chassis/1)# no trap
trap - Disable trap generation
fiberdriver(chassis/1)# no trap ?
<cr> - Disable all available traps for this location
> - Redirect output to a file
>> - Append output to file
NAME - Disable generation of a specific trap
fiberdriver(chassis/1)#
Specific trap names are listed in the MIB file. For example, the
no
trap
nbsCmmcTrapPortEnabled
command disables the "PortEnabled" trap. For easier CLI configuration,
start by issuing a
show traps
command. All traps for that element display along with the emit status.
Copy the name listed and issue a
(no) trap NAME
command to toggle the trap.
fiberdriver(chassis/1)# show traps
Name Emit
============================================ ====
NBS-CMMC-MIB::nbsCmmcTrapPowerSupplyFailure yes
NBS-CMMC-MIB::nbsCmmcTrapPowerSupplyRestored yes
NBS-CMMC-MIB::nbsCmmcTrapFanFailure yes
NBS-CMMC-MIB::nbsCmmcTrapFanRestored yes
NBS-CMMC-MIB::nbsCmmcTrapChassisTooHot yes
NBS-CMMC-MIB::nbsCmmcTrapChassisTooCold yes
NBS-CMMC-MIB::nbsCmmcTrapChassisTempOk yes
fiberdriver(chassis/1)# no trap NBS-CMMC-MIB::nbsCmmcTrapFanFailure
fiberdriver(chassis/1)# show traps
Name Emit
============================================ ====
NBS-CMMC-MIB::nbsCmmcTrapPowerSupplyFailure yes
NBS-CMMC-MIB::nbsCmmcTrapPowerSupplyRestored yes
NBS-CMMC-MIB::nbsCmmcTrapFanFailure no
NBS-CMMC-MIB::nbsCmmcTrapFanRestored yes
NBS-CMMC-MIB::nbsCmmcTrapChassisTooHot yes
NBS-CMMC-MIB::nbsCmmcTrapChassisTooCold yes
NBS-CMMC-MIB::nbsCmmcTrapChassisTempOk yes
fiberdriver(chassis/1)#