MRMC MRMC-2132-00 Скачать руководство пользователя страница 5

1

Bloop Light Quick Start Guide

Bloop Light

Quick Start Guide

Chapter 1  

Quick start

Important safety instructions

To ensure the best from the product, please read this manual carefully. 
Keep it in the safe place for future reference.

To reduce the risk of electric shock, do not remove the cover from the 
unit. No user serviceable parts inside. Refer servicing to qualified 
personnel.

Power and connections

Do not plug in or attempt to operate an obviously damaged 
unit.

General care

Do not force switches or external connections.

Do not attempt to clean the unit with chemical solvents or 
aerosol cleaners, as this may damage the unit. Use a clean dry 
cloth.

Do not use around flammable gas. All electrical equipment can 
generate sparks that can ignite flammable gas. 

Keep the equipment dry. The system has 

not

 been made 

weatherproof. Do not use with wet hands. 

Keep away from pets and children. The head has powerful 
motors that can pinch, so take care not to get your hands 
trapped in the head or cabling. 

Keep cables tidy. Use cable ties to keep them out of harm’s way. 
If you have a head with slip rings then make use of them; avoid 
running any cables between the base and the rotating head or 
camera. 

Location

Installation of this unit should be away from sources of excessive heat, 
vibration, and dust.

Содержание MRMC-2132-00

Страница 1: ...Bloop Light Quick Start Guide QSG Product Code MRMC 2174 00 Product Covered MRMC 2132 00...

Страница 2: ...information in this document is accurate and up to date Mark Roberts Motion Control continuously strives to improve their products and may make changes to the hardware firmware and software described...

Страница 3: ...Important safety instructions 1 Power and connections 1 General care 1 Location 1 Intellectual property 2 Overview 2 Connecting the cables 3 Configuration A Connecting Directly to R 14 3 Configuration...

Страница 4: ...Bloop Light Quick Start Guide iv...

Страница 5: ...lean the unit with chemical solvents or aerosol cleaners as this may damage the unit Use a clean dry cloth Do not use around flammable gas All electrical equipment can generate sparks that can ignite...

Страница 6: ...It can be sat just in the corner of the frame to the safe area so that it is not a part of the final film or the bloop light laser s miniature flash can be included in the frame telling the editor wh...

Страница 7: ...as it is usually used to trigger the Bloop light YYou can change this name in Flair by using the same menu options that you use to add triggers to a move Setups Outputs 1 Bloop 2 3 etc See the Flair d...

Страница 8: ...nnection The Bloop light plug itself black in the photograph is wired for two inputs If you plug the Bloop light into the BLOOP connector on the ribbon cable you can trigger it with the Trigger 1 sign...

Страница 9: ...n this configuration As in Configuration A above in Flair the button for Trigger 1 is labelled Bloop by default unless you have changed it as it is usually used to trigger the Bloop light See the Flai...

Страница 10: ...he bloop light When pressed the bloop light should activate and deactivate upon release 4 You can switch the bloop light on and off up to 15 times within the move The frame count fractional if desired...

Страница 11: ...ccessed using the menu Setups Output Triggers Cyclic Triggers Bloop light flash can be set to repeat in a cycle throughout the move Enter the On For value defining the duration of the trigger Enter a...

Страница 12: ...Bloop Light Quick Start Guide 8 Notes...

Страница 13: ...Bloop Light Quick Start Guide 9 Notes...

Страница 14: ...Bloop Light Quick Start Guide 10 Notes...

Страница 15: ...Bloop Light Quick Start Guide 11 Notes...

Страница 16: ...Mark Roberts Motion Control Ltd Unit 3 South East Studios Blindley Heath Surrey RH7 6JP United Kingdom Telephone 44 0 1342 838000 info mrmoco com www mrmoco com...

Отзывы: