Operating Instructions and Owner’s Manual

Mr. Heater | Unvented Natural Gas Fired Room Heater

Specifications

MODEL

MHVFRD20NG

MHVFRD30NG

Input Rates

20,000 BTU/HR High/ 12,500 BTU/HR Low

30,000  BTU/HR High/ 20,000 BTU/HR Low

Type of Gas 

Natural Gas Only 

Natural Gas Only 

Ignition 

Piezo

Piezo

Manifold Pressure 

4.5 Inches of Water 

4.5 Inches of Water 

Inlet Gas Pressure (Maximum)  14 Inches of Water 

14 Inches of Water 

Inlet Gas Pressure (Minimum) 

7 Inches of Water 

7 Inches of Water 

Thermostatic Control 

No

No

Clearances: Inches (mm)

 Top 

36” (91.4 cm) 

36” (91.4 cm) 

 Sides 

10” (25.4 cm) 

10” (25.4 cm) 

  Floor (min. to top of carpet)  3” (7.6 cm) 

3” (7.6 cm) 

  Fabric / flammable objects 

36” (91.4 cm) 

36” (91.4 cm) 

CONTENTS

2    

Warnings

3    

Specifications

3    

Precautions

4    

Installation

9    

Operation

Lighting

Shutdown

10    

Maintenance

11    

Troubleshooting

14

   Parts List

16   

Ordering Parts/Warranty

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

PRECA

UTIONS

PRECAUTIONS:

1.  An unvented room heater having an 

input rating of more than 10,000 BTU 
(2931 W) (i.e. the MHVFRD20NG, 
MHVFRD30NG) shall not be installed 
in a bedroom or bathroom, or any 
place where a strong wind would shut 
down the appliance.

2.  This heater needs outside ventilation 

air to run properly. The Oxygen 
Depletion Sensor (ODS) safety shutoff 
system shuts down the heater if not 
enough fresh air is available. See Fresh 
Air for Combustion and Ventilation, 
page 5.

3.  Keep all air openings in heater clear, 

free of debris or any blockage. This 
will ensure that enough air for proper 
combustion enters the heater.

4.  If heater shuts off, do not relight 

until you provide fresh, outside air. If 
heater keeps shutting off, it requires 
servicing.

5.  Turn off and let cool before servicing. 

Only a qualified service person should 
service and repair heater.

6.  Do not run heater:
•  Where flammable liquids or vapors are 

used or stored

•  During dusty conditions.

7.  Before using furniture polish, wax, 

carpet cleaner or similar products, turn 
heater off. If heated the vapors from 
these products may create a white 
powder residue within burner box or 
on adjacent walls or furniture.

8.  Do not use heater if any part has 

been underwater. Immediately call a 
qualified service technician to inspect 
the room heater and to replace any 
part of the control system and any gas 
control which has been underwater.

9.  Operating heater above elevations 

of 4,500 feet could cause pilot/ODS 
to shutdown heater.

10. Always run heater with control knob 

in a locked position. Never set control 
knob between locked positions. Poor 
combustion and higher levels of 
carbon monoxide may result if control 
knob is left between locked positions.

Carbon Monoxide Poisoning:

Early signs of carbon monoxide poisoning 
resemble the flu, with headaches, 
dizziness, or nausea. If you have these 
signs, the heater may not be working 
properly. Get fresh air at once! Have 
heater serviced. Some people are more 
affected by carbon monoxide than others. 
These include pregnant women, persons 
with heart or lung disease or anemia, 
those under the influence of alcohol, and 
those at high altitudes.

**Operating heater above elevations of 4,500 feet could cause pilot/ODS to shutdown heater.**

DANGER: C

arbon monoxide 

poisoning may lead to death. 

SOCIAL MEDIA

In order to provide the best service possible Mr. Heater is now giving you more 

ways to get in touch with us:
WEBSITE:   Mr. Heater’s full line of product are now at:

 www.mrheater.com

 FACEBOOK: Find us on Facebook 

 

 TWITTER: Find us on twitter 

 YouTube: There are now informational videos on Youtube.

Содержание MHVFRD20NG

Страница 1: ...r other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phon...

Страница 2: ...erating the heater Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequen...

Страница 3: ...air If heater keeps shutting off it requires servicing 5 Turn off and let cool before servicing Only a qualified service person should service and repair heater 6 Do not run heater Where flammable liq...

Страница 4: ...plied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater FRESH AIR FOR COMBUSTION AND VENTILATION Establishing Adequate V...

Страница 5: ...ect vent draws combustion air from the outdoors and vents to the outdoors Example Gas water heater 40 000 Btu hr Vent Free Heater 20 000 Btu hr Total 60 000 Btu hr 4 Compare the maximum Btu hr the spa...

Страница 6: ...to Natural Gas Equipment shutoff valve Ground joint union Test gauge connection Sediment trap Tee joint Pipe wrench A CSA AGA certified equipment shutoff valve with 1 8 NPT tap is an acceptable altern...

Страница 7: ...of heater See Figure 9 2 Place heater onto mounting bracket Slide horizontal slots onto stand out tabs on mounting bracket Installing Bottom Mounting Screws 1 Locate two bottom mounting holes These ho...

Страница 8: ...odes WARNING This appliance requires a 3 8 NPT National Pipe Thread inlet connection to the pressure regulator Use of floor mounting feet will require you to use a 3 8 NPT street elbow to make gas con...

Страница 9: ...one in your building Figure 13 Figure 14 Equipment Shutoff Valve Open Closed To gas meter Control Valve Equipment Shutoff Valve Immediately call you gas supplier from a neighbor s phone Follow the gas...

Страница 10: ...gandproperty damage WARNING Turn off heater and let cool before servicing CAUTION You must keep control areas burner and circulation air passageways of heater clean Inspect these areas of heater befor...

Страница 11: ...company b Clean ODS pilot see Cleaning and Maintenance page 10 9 Thermocouple damaged 9 Replace thermocouple 10 Control Valve damaged 10 Replace control valve REMEDY SYMPTOM Burner does not light afte...

Страница 12: ...ice is clogged 2 Clean burner orifice see Cleaning and Maintenance on page 10 or replace burner orifice 1 When heated vapors from furniture polish wax carpet cleaners etc turn into white powder residu...

Страница 13: ...nd remove foreign matter 2 Gas leak See WARNING statement at top of page 11 2 Locate and correct all leaks see Checking Gas Connections page 8 REMEDY SYMPTOM SYMPTOM Heater shuts off in use ODS operat...

Страница 14: ...Regulator Mounting Bracket 1 9 80009 06 Orifice 1 10 80172 Selector Valve Adapter 2 11 80173 Aluminum Valve 1 12 80171 Valve Bracket 1 Item Part No Description 13 80058 Floor Mounting Feet Beige 1 802...

Страница 15: ...Front Panel Beige 1 80208 Front Panel White 1 3 80023 Reflector 1 4 80057 ODS Assembly w Thermocouple NG 1 5 80109 Burner Assembly 1 6 80082 Regulator 1 7 NA Regulator Connection 1 8 80055 Regulator M...

Страница 16: ...M 5 00 PM EST Monday through Friday Please include the model number date of purchase and description of problem in all communication LIMITED WARRANTY Mr Heater Inc warrants its heaters and accessories...

Отзывы: