Operating Instructions and Owner’s Manual

Mr. Heater | Unvented Natural Gas Fired Room Heater

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

Figure 9

Figure 8

Figure 10

Figure 11

Figure 7

Horizontal 
Slots

Mounting 
Bracket 
mounted 
to wall

Mark mounting hole locations and drill 
holes where indicated. Allow for minimum 
clearances.

See clearance 
specs on Pg. 3

A

djoining W

all

16” (Lg)
12-9/64” (Sm)

18” Min.

Attaching to Wall Stud

This way is the best providing the 
strongest mounting in wood frame 
houses.
For attaching mounting bracket to wall 
studs:
1.  Drill holes at marked locations using 

9/64” drill bit.

2.  Place mounting bracket onto wall. 

Line up holes on each end of bracket 
with hole drilled in wall.

3.  Insert mounting screws through 

bracket and into wall studs.

4.  Tighten screws until mounting bracket 

is firmly fastened to wall studs.

Attaching to Wall Anchor

This way allows you to attach 
mounting bracket to hollow walls (wall 
areas between studs) or to solid walls 
(concrete or masonry).
1.  Tape mounting bracket to wall where 

heater will be located. Make sure 
mounting bracket is level. For wall 
stud mounting locate one end of the 
mounting bracket over a wall stud.

2.  Mark screw locations on wall.  

See figure 7.

3.  Remove tape and mount bracket to 

wall.

Note:

 Wall anchors, mounting screws, 

and spacer are in hardware package. 
The hardware package is provided with 
heater.

4.  Drill holes at marked locations using 

5/16” drill bit. For solid walls (concrete 
or masonry), drill at least 1” deep.

5.  Fold wall anchor as shown in Figure 8 

below.

6.  Insert wall anchor (wings first) into 

hole. Tap anchor flush to wall.

7.  For thin walls (1/2” or less) insert red 

key into wall anchor. 

8.  Place mounting bracket onto wall. 

Line up holes on each end of bracket 
with wall anchors.

9.  Insert mounting screws through 

bracket and into wall anchors.

10. Tighten screws until mounting bracket 

is firmly fastened to wall.

Placing Heater on Mounting Bracket

1.  Locate two horizontal slots on back 

pane of heater. See Figure 9.

WARNING: 

Maintain minimum 

clearances shown in Figure 7. If you 
can, provide greater clearances from 
the floor and joining wall. 

Screw Hole

Screw Hole

2.  Place heater onto mounting bracket. 

Slide horizontal slots onto stand-out 
tabs on mounting bracket.

Installing Bottom Mounting Screws

1.  Locate two bottom mounting holes. 

These holes are near bottom on back 
panel of heater. See Figure 10.

2.  Mark screws locations on wall.
3.  Remove heater from mounting 

bracket.

4.  If installing bottom mounting screw 

into hollow or solid wall, install wall 
anchors. Follow steps 1 through 4 
under Attaching to Wall using Anchor. 
If installing bottom mounting screw 
into wall stud, drill holes at marked 
locations using 9/64” drill bit.

5.  Re-place heater onto mounting 

bracket.

6.  Place spacers between bottom 

mounting holes and wall anchor or 
drilled hole.

7.  Hold spacer in place with one hand. 

With the other hand, insert mounting 
screw through bottom mounting 
hole and spacer. Place tip of screw in 
opening of wall anchor or drilled hole.

8.  Tighten both screws until heater is 

firmly secured to wall. Do not over 
tighten.

Note:

 Do not re-place front panel at 

this time. 

9.  Replace front panel after making gas 

connections and checking for leaks.

Floor Mounting Away From Wall

Installing Support Feet (See Figure 11):
1.  Lay heater onto table on its back with 

bottom edge overhanging table edge.

2.  Securely attach feet to bottom of 

heater using 2 – self-tapping screws 
each.

Note:

 Feet should have long end going 

out the front of heater, and the edge 
coinciding with side of heater. If feet 
overhang side of the heater, switch leg 
location.

3.  Place heater on non-combustible 

surface (see Locating Heater, page 
6) before proceeding with gas 
connection. If this will be a permanent 
location, heater may be locked into 
position using anchoring holes in 
mounting feet.

Note:

 Use of floor mounting feet will 

require you to use a 3/8 NPT street 
elbow to make gas connection.

INST

ALLATION

Содержание MHVFBF20NGBT

Страница 1: ...information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and li...

Страница 2: ...erating the heater Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequen...

Страница 3: ...ce 2 This heater needs outside ventilation air to run properly The Oxygen Depletion Sensor ODS safety shutoff system shuts down the heater if not enough fresh air is available See Fresh Air for Combus...

Страница 4: ...ult in lower fuel bills Blower Fan Control Switch Operation On models equipped with an electrical blower the blower switch has three positions MANUAL OFF and AUTO In AUTO the blower will turn on and o...

Страница 5: ...or openings add the volume of these rooms to the total volume of the space 2 Divide the space volume by 50 cubic feet to determine the maximum Btu hr the space can support Example 2592 cu ft volume o...

Страница 6: ...s your primary heat source for the duration of the outage Check Gas Type Use only Natural gas If your gas supply is not Natural gas do not install heater Call dealer where you bought heater for proper...

Страница 7: ...s 10 Tighten screws until mounting bracket is firmly fastened to wall Placing Heater on Mounting Bracket 1 Locate two horizontal slots on back pane of heater See Figure 9 WARNING Maintain minimum clea...

Страница 8: ...NING This appliance requires a 3 8 NPT National Pipe Thread inlet connection to the pressure regulator Use of floor mounting feet will require you to use a 3 8 NPT street elbow to make gas connection...

Страница 9: ...Light heater See Operating Your Heater 8 Turn off heater See To Turn OFF Gas to Appliance 9 Replace lower front panel Figure 13 Figure 14 Figure 15 Equipment Shutoff Valve Open Closed To gas meter Co...

Страница 10: ...for repairs Figure 17 Figure 16 Correct Pilot Position Incorrect Pilot Position CAUTION Do not try to adjust heating level by using equipment shutoff valve 8 When the pilot is lit turn the control kno...

Страница 11: ...s vacuum cleaner pressurized air or small soft bristled brush to clean CLEANING BURNER PILOT AIR HOLE INLET We recommend that you clean the unit every 2 500 hours of operation or every three months We...

Страница 12: ...Clean burner orifice see Cleaning and Maintenance on page 11 or replace burner orifice 2 Burner orifice diameter to small 2 Replace burner orifice 3 Inlet gas pressure is too low 3 Contact local gas...

Страница 13: ...as regulator 7 Thermocouple connection loose at control valve 7 Hand tighten thermocouple nut until snug and then tighten 1 4 turn more 8 Pilot flame not touching thermocouple which allows thermocoupl...

Страница 14: ...lean ODS pilot see Cleaning and Maintenance page 11 1 Gas leak See WARNING statement at top of page 12 1 Locate and correct all leaks see Checking Gas Connections page 9 2 Control valve is defective 2...

Страница 15: ...Combustion and Ventilation on pages 3 5 REMEDY SYMPTOM Heater produces a clicking ticking noise just after burner is lit or shut off CAUSE 1 Metal expanding while heating or contracting while cooling...

Страница 16: ...r Mounting Bracket 1 9 80009 06 Orifice 1 10 80014 Igniter Wire 1 11 80081 Thermostat Valve 1 Item Part No Description 12 80176 Igniter Module 1 13 80010 Thermostat Valve Mounting Bracket 1 14 80184 I...

Страница 17: ...r Mounting Bracket 1 9 80009 08 Orifice 1 10 80014 Igniter Wire 1 11 80081 Thermostat Valve 1 Item Part No Description 12 80176 Igniter Module 1 13 80010 Thermostat Valve Mounting Bracket 1 14 80184 I...

Страница 18: ...15 80014 Igniter Wire 1 Item Part No Description 16 80176 Igniter Module 1 17 80184 Igniter Module Mounting Bracket 1 18 80010 Thermostat Valve Mounting Bracket 1 19 80058 Floor Mounting Feet Beige 1...

Страница 19: ...1 12 80009 09 Orifice 1 13 80073 Orifice Adapter 1 14 80081 Thermostat Valve 1 15 80014 Igniter Wire 1 Item Part No Description 16 80176 Igniter Module 1 17 80184 Igniter Module Mounting Bracket 1 18...

Страница 20: ...ase include the model number date of purchase and description of problem in all communication LIMITED WARRANTY Mr Heater Inc warrants its heaters and accessories to be free from defects in material an...

Отзывы: