MrCool MWUC 5 Series Скачать руководство пользователя страница 1

Please read this manual carefully before installation and keep it for future reference.

Please keep this manual where the operator can easily find it. Inside, you 

will find helpful hints on how to use and maintain your unit properly. 

Installation & Owner’s 

Manual

U-Shaped Window Unit 

Air Conditioner

Model: MWUC**5

Due to updates and constantly improving performance, the information and instructions 

within this manual are subject to change without notice. Please visit 

www.mrcool.com/documentation to ensure you have the latest version of this manual.

Version Date: 8-16-21

Содержание MWUC 5 Series

Страница 1: ...on how to use and maintain your unit properly Installation Owner s Manual U Shaped Window Unit Air Conditioner Model MWUC 5 Due to updates and constantly improving performance the information and inst...

Страница 2: ...29 Troubleshooting Tips 30 1 2 3 4 5 NOTE This air conditioner is designed to be operated in the conditions in the table below If the unit is operated outside of these temperatures its performance co...

Страница 3: ...ing or pulling the plug from the outlet Make sure the unit is switched o before plugging or unplugging it from the outlet otherwise it could cause electric shock or re due to heat generation DO NOT mo...

Страница 4: ...nstalled in a window be sure to clean the area before the installation and remove the screen if the window is equipped with one When handling the air conditioner be careful to avoid being cut by the s...

Страница 5: ...the plug from an outlet by pulling on the cord Always grab the head of the plug when removing it from the outlet Otherwise it could cause electric shock or damage to the cord DO NOT block the air inle...

Страница 6: ...ow active and supplying power to the unit Some products may indicate this with a light on the head of the plug Please note the following warnings in regards to the use of this device DO NOT use this d...

Страница 7: ...re a single outlet with other electrical appliances as improper power supply could cause electric shock and or re R32 Refrigerant is used within this air conditioner which is classi ed as being ammabl...

Страница 8: ...rant with an appropriate refrigerant detector prior to and during work This is to ensure the technician is aware if there is any ammable refrigerant in the air around the work area 6 5 A Fire Extingui...

Страница 9: ...ies are aware and advised of the issue Initial safety checks should include the following All capacitors are discharged this should be performed in a manner that is safe in order to avoid the possibil...

Страница 10: ...d be calibrated in a refrigerant free environment Ensure the detector is not a potential source of ignition and is suitable for the type of refrigerant used Leak detection equipment should be set at a...

Страница 11: ...pletion of charging but prior to decommissioning A follow up leak test should performed prior to leaving the site 14 Decommissioning Before completing the decommissioning process it is essential that...

Страница 12: ...complete with a pressure relief valve and associated shut o valves which should be in good working order Empty recovery cylinders are evacuated and cooled before recovery occurs if possible The recov...

Страница 13: ...ware Right Extension Arm For 26 36 windows Type B 1 4 Screw Type A 1 2 Screw Type A 1 Screw 3 2 1 1 2 Type B 1 2 Screw 2 Main Bracket Window Sash Lock Additional Side Arm Foam Window Sealing Foam Brac...

Страница 14: ...o install in standard double hung windows with opening widths of 22 to 36 inches 559 mm to 914 mm and a minimum window height of 13 75 inches 349 mm Before you begin the installation ensure the window...

Страница 15: ...Arm located on the Horizontal Bracket and adjust the arm outward Then install the Right Extension Arm into the right side of the Horizontal Bracket Please refer to Fig 2 C Now measure the width of the...

Страница 16: ...Bracket into the window opening Ensure that the Horizontal Bracket and the Left and Right Extension Arms are located on the indoor side of the window Please refer to Fig 4 INSTALL SUPPORT BRACKET A1...

Страница 17: ...lied Type A 1 2 screws 12 7 mm into the vertical portion of the bracket and windowsill as shown in Fig 6 below For Wooden Type Windows with a Flat Seal A3 Secure the bracket to the windowsill by drill...

Страница 18: ...Please refer to Fig 9 D Check the level again and ensure the bracket and arms are secure After making any necessary adjustments insert the Cotter Pins into the holes of the Main Support Pins as shown...

Страница 19: ...er on top of the support bracket Ensure the grooves on the bottom of the air conditioner align with the Main Supports Please refer to Fig 12 Fig 13 below Using a level ensure that the unit has the pro...

Страница 20: ...that attaches to the unit itself Please refer to Fig 16 Use the Type B 1 4 Screw Fig 16 Use the Type B 1 2 Screw WARNING Failure to install the Open Window Brackets could cause injury or property dama...

Страница 21: ...ows with Lipped Sill Window Sealing Foam Fig 18 Additional Side Arm Foam Wooden Type Windows with Flat Sill Window Sealing Foam Fig 19 Side Arm Foam Side Arm Foam Air Conditioner Side Window Sealing F...

Страница 22: ...ck Opening Fig 23 NOTE Fig 22 Fig 23 below are to show how the Anti Tip Bracket is to be installed in the window track Note the Side Arm Foam installed in the previous steps is not shown in this illus...

Страница 23: ...heck for gaps Fill any with included foam as needed F Extend the Integrated Window Locks located in the U channel until they contact the window Please refer to Fig 24 NOTE For additional security you...

Страница 24: ...8 mm Board thickness as required for proper pitch to rear along entire sill Fasten with nails or screws Storm window frame or other obstruction Fig 28 IF AC IS BLOCKED BY A STORM WINDOW Add wood as sh...

Страница 25: ...d at the front of the unit The following illustration and descriptions represent noises that may be heard from the air conditioner during normal operation These are normal and do not indicate there is...

Страница 26: ...fortable air ow see Air Directional Louvers section and illustrations to the right 6 Once the room has cooled adjust the thermostat to the setting you nd most comfortable 7 Make sure that the air ow i...

Страница 27: ...no display Turning the unit ON or OFF at any time or adjusting the timer setting to 0 0 will cancel the Auto Start Stop timed program ON OFF Press ON OFF button to turn the unit on or o 1 2 5 3 4 1 2...

Страница 28: ...rature When COOL Mode is selected the fan speed can be adjusted by pressing the fan button 3 Operation of DRY mode In this mode the air conditioner will operate in the form of a dehumidi er Since the...

Страница 29: ...ay will show the room temperature If the room temperature is too high or low it will display HI or LO Display Error codes Should an error occur the unit may stop operation or continue to run safely If...

Страница 30: ...ry before replacing Instead of washing you could also vacuum the lter clean NOTE Never use hot water above 104 F 40 C to clean the air lter Never attempt to operate the unit without the air lter insta...

Страница 31: ...r may be dirty Clean lter Refer to Care and Cleaning section To defrost set to FAN ONLY mode Thermostat set too cold for night time cooling To defrost the coil set to FAN ONLY mode Then set temperatur...

Страница 32: ...from humid room This is normal during excessively humid days Remote Sensing Deactivating Prematurely some models Remote control not located within operating range Use remote control within 20 feet an...

Страница 33: ...esign and speci cations of this product and or manual are subject to change without prior notice Consult with the sales agency or manufacturer for details U Shaped Window Unit Air Conditioner Model MW...

Отзывы: