27
1. POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
2. FACTORY INSTALLED JUMPER.
3. MUST CONNECT THE 24VAC COMMON WHEN USING L. THE TERMINAL IS SHOWN AS EQUIPMENT MONITOR
.
4. "O/B" TERMINAL SET TO CONTROL AS EITHER "O" OR "B" IN THE INSTALLER SETUP.
Fig. 18. Typical hookup of multi-stage heat pump with no auxiliary/backup heat (2H/2C heat pump).
Содержание MST03
Страница 1: ...MRCOOL Universal WiFi Thermostat...
Страница 2: ......
Страница 4: ......
Страница 11: ...7 Fig 1 Thermostat Dimensions in inches mm...
Страница 12: ...8 Fig 2 Thermostat back case dimensions in inches mm...
Страница 13: ...9 Fig 3 Thermostat cover plate dimensions in inches mm...
Страница 14: ...10 Fig 4 Selecting thermostat location...
Страница 16: ...12 Fig 5 Mounting wall plate...
Страница 20: ...16 Fig 7 Inserting wires in terminal block IMPORTANT Use 18 gauge thermostat wire...
Страница 35: ...31 Fig 21 Mount thermostat to wall plate...
Страница 48: ...44 OPERATION Fig 23 Thermostat Keys Fan Choose fan mode...
Страница 49: ...45 Fig 24 Thermostat Display...
Страница 64: ...60 Fig 33 Fig 34 4 Press the key on thermostat screen until the flash Fig 35...