MRC TM-969 Скачать руководство пользователя страница 1

Your purchase of this INFRARED THERMOMETER marks a step

 

forward for 

you into the field of precision measurement.

 

Although this  METER is a 

complex and delicate instrument, its

 

durable structure developed. 

Please read the following

 

instructions carefully and always keep this 

manual within easy

 

reach.

       OPERATION MANUAL

 

PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 

3, Hagavish st. Israel 58817  Tel: 972 3 5595252, Fax: 972 3 5594529   

[email protected]

 

MRC.

1

.2

2

Dual laser + type K thermometer

1000  

 

INFRARED 

THERMOMETER

Model : TM-969

Содержание TM-969

Страница 1: ...strument its durable structure developed Please read the following instructions carefully and always keep this manual within easy reach OPERATION MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERAT...

Страница 2: ...tton 4 3 2 Down Button 4 3 3 LCD Display 4 3 4 Up Button 4 3 5 Mode Button 4 3 6 Measure Switch 4 3 7 Battery Cover 4 3 8 Infrared Lens 4 3 9 Laser 4 3 10 LED 4 3 11 Thermocouple Socket 4 4 MEASURING...

Страница 3: ...ock mode Last measurement memory Hi Lo Temperature Audio Alarm Laser target and Back light On Off control Adjustable emissivity value from 0 1 to 1 00 Preset emissivity value at 0 95 Power supply by t...

Страница 4: ...1 1 000 1 000 1 1 1 000 1 000 Circuit Exclusive microcomputer circuit Emissivity Adjustment range 0 10 to 1 00 Adjustment step 0 01 0 95 default emissivity value Infrared Temp Thermocouple pie Temp Se...

Страница 5: ...5 mA with target light on Approx DC 29 5 mA Operating 0 to 50 32 to 122 Temperature Operating Less than 80 RH Humidity Weight 386 g 0 85 LB Dimension 203 x 197 x 47 mm 8 0 x 7 7 x 1 8 inch Standard O...

Страница 6: ...PANEL DESCRIPTION 3 1 Emissivity Button 3 2 Down Button 3 3 LCD Display 3 4 Up Button 3 5 Mode Button 3 6 Measure Switch 3 7 Battery Cover 3 8 Infrared Lens 3 9 Laser 3 10 LED 3 11 Thermocouple Socket...

Страница 7: ...e Spot is 50 1 The two laser points are the reference for the target spot size Please make sure the target area is within the field of view 3 Press Emissivity Button 3 1 Fig 1 for setting the emissivi...

Страница 8: ...AL or Lo Alarm LAL then press Measure Button 3 6 Fig 1 to confirm it For example When the reading 26 9 LAL 27 the Low icon will flash and you will hear a beep sound Connect the thermocouple with Therm...

Страница 9: ...1 for laser function ON OFF With flash light be turned on in the same time as laser 5 MEASURING CONSIDERATION 5 1 LCD error message The thermometer incorporates visual diagnostic messages as follows H...

Страница 10: ...splayed when the temperature being measured is outside of the measurement range 6 BATTERY REPLACEMENT When the Low Battery icon indicates the battery is low the battery should be replaced immediately...

Страница 11: ...for many general purpose application Thermocouple Measure Range 50 to 900 Probe 50 to 1650 Type K TP 02A Dimension 10cm tube 3 2mm Dia Thermocouple Measure Range 50 to 1200 Probe 50 to 2200 Type K TP...